Features of Schneider explosion-proof inverter box
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It is mainly adjusted by changing its output frequency to adjust the speed of ordinary three-phase asynchronous motor, so as to reach the production process.
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
The selection method of inverter power - Schneider
The system power is equal to the product of the inverter power and the motor power, as long as both are operating at a higher power, the system power is higher. From the power point of view, when selecting the power of the inverter, the following points should be noted:
...
|
|
Motor control mode of Schneider inverter
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Schneider UPS power supply installation steps
UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...
|
|
Schneider diode selection experience and substitution method
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...
|
|
Introduction to Schneider PLC series
1. LMC058 & LMC078 Modicon Motion Controller Product Information
Faster machine planning
The motion controller uses the same programming software as the PLC;
Custom-made utility blocks for complex use;
Dedicated motion function library for programming, debugging, and diagnosis ...
|
|
Introduction to Schneider inverter fault code and maintenance method
1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...
|
|
Precautions for the selection of Schneider molded case circuit breaker
1. Shell current and rated current
The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.)
...
|
|
Precautions for the use and maintenance of instruments and meters - Schneider
Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument:
1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...
|
|
Schneider inverter external potentiometer connection
The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
Schneider instrumentation accuracy
It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...
|
|
Schneider inverter series at a glance
1. ATV11 series
The Schneider ATV11 series is primarily used in three-phase asynchronous motor inverters with a power range of 0.18 to 2.2 kW.
2. ATV12 series
ATV12 Schneider inverter for power scale 0.18k...
|
|
The reason for the inverter trip - Schneider
Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about.
1. Overload jump ...
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|
Schneider miniature circuit breaker problem analysis and answer
Fault 1: The shell of Schneider MCB product is yellowed or burned.
Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals.
Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency.
...
|
|
Schneider inverter disturbance and treatment method
A. Methods of Communication:
(1) Radiation disturbance
(2) Conduction disturbance
B. Immunity Methods
With regard to nuisance signals transmitted by radiation methods, they are primarily weakened by wiring and shielding the radioactive source and the disturbed lines.
About Tong ...
|
|
Technical causes of Schneider low-voltage circuit breaker accidents
(1) Operational failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the fundamental and important function of the high-voltage circuit breaker is to act correctly and quickly remove the fault of the power grid. If the circuit breaker is dragged or misoperated, it will pose a serious threat to the power grid, first of all: (1) expansion ...
|