Introduction to the functions of various types of Sick sensors

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

1. Industrial sensors

The SICK industrial sensor portfolio includes the widest range of photoelectric sensors, fiber optic amplifiers, color mark sensors, proximity sensors, magnetic cylinder sensors, and measuring light curtains in the automation field, which are mainly used for recording, counting, classifying, and positioning objects, detecting the shape and position of objects, and distinguishing between color and surface properties.

2. Vision sensor

Vision sensors from SICK are equipped with a component positioning toolset for precise positioning of both free-form and fixed-form objects. It adapts to changes in ambient light as well as small distance changes.

3. Ranging sensor

The range sensor series includes: short-range laser distance sensor, medium-range laser distance sensor, long-range laser distance sensor, barcode positioning sensor, infrared data transmission system, DMP positioning sensor, ultrasonic sensor, speed sensor.

4. Process instrument sensor

SICK industrial instrumentation sensors include pressure transmitters/switches, level gauges/switches, flow sensors, bulk material flow detection systems, and temperature sensors, which are used to monitor the amount of fluid changes (pressure, level, temperature, and flow) in the automated production process to ensure reliable and stable automation processes.
Introduction to the functions of various types of Sick sensors

More on that
Sick | Cameras from RIBE Technik are used to monitor the assembly facility Sick | Cameras from RIBE Technik are used to monitor the assembly facility

Quality assurance through programmable imaging: RIBE Technik from Schwabach has developed an innovative bumper assembly system that includes an inspection system. Machine vision from SICK enables the identification of individual components and the monitoring of each operating process as a special system concept ...

New Arrivals | Sick safety locking device FLEXLOCK New Arrivals | Sick safety locking device FLEXLOCK

SICK's new generation of RFID monitoring security locking device FLEXLOCK is officially launched. The FLEXLOCK safety locking device for RFID monitoring has an operating radius of 180° for greater flexibility and is also suitable for protective doors with smaller radii. LED lights can be selected from ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.

Introduction to the characteristics of Sick sensors Introduction to the characteristics of Sick sensors

Static characteristics of Sick sensors The static characteristics of the Sick sensor refer to the correlation between the output and the input of the Sick sensor for the static input signal. Since the input and output are not time-dependent, the relationship between them, i.e. the static ...

Sick launched a new diffuse reflection long array photoelectric sensing Sick launched a new diffuse reflection long array photoelectric sensing

The logistics industry has always been a strong area of SICK, in response to the detection of various goods on different conveyor lines and the diverse needs of customers, SICK has launched a series of photoelectric sensors such as G6, Z18, W16, W26 and Ray26 - which can detect cartons, baskets, uneven appearance, transparent bottles, laminated bags, etc.

SICK brought new products to the Industry Fair SICK brought new products to the Industry Fair

The 17th China International Industry Fair (IAS2015) was held in the National Convention and Exhibition Center (Shanghai) from November 3 to 7, 2015.

Sick's 3D vision product Ruler3000 series has been expanded with two new members Sick's 3D vision product Ruler3000 series has been expanded with two new members

Two new members of the Ruler3000 family of Sick 3D vision products have been added, named Ruler3120 and Ruler3008.   The new 3D vision sensor solution Ruler3000 from SICK is suitable for a wide range of industrial applications and is characterized by its high speed and image quality. 3D Visual Transmission ...

Sick TMx22 tilt sensor – smaller, smarter Sick TMx22 tilt sensor – smaller, smarter

The miniaturization, integration, and intelligence of sensors are the main trends of industrial development, and the increasing demand for small and integrated smart chips in industrial scenarios also provides better means for equipment integration and intelligence. Sick is also deeply aware of the small size of the large ...

Sick sensors – the future of photoelectric sensors Sick sensors – the future of photoelectric sensors

Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals. Photoelectric sensors are generally composed of three parts: light source, optical path and optoelectronic components. The measured change is converted into a change in the optical signal, and then the optoelectronic component is used to further ...

Sick Sensors - Introduction to the static and dynamic characteristics of displacement sensors Sick Sensors - Introduction to the static and dynamic characteristics of displacement sensors

Dynamic features: The so-called dynamic characteristics of the sensor refer to the characteristics of the output of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are often expressed in terms of its response to some standard input signal. This is because the sensor's response to a standard input signal ...

Sick Sensors – How to use the Contrast Sensor Sick Sensors – How to use the Contrast Sensor

1. Wiring There are 4 outgoing wires of the sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. The lines are not ...

Sick sensor - infrared sensor should be applied and precautions Sick sensor - infrared sensor should be applied and precautions

Infrared sensors are sensors that use the physical properties of infrared rays to make measurements. Infrared, also known as infrared light, has the properties of reflection, refraction, scattering, interference, absorption, etc. Any substance that has a certain temperature above absolute zero can radiate infrared rays. ...

Introduction to the product functions of Sick Introduction to the product functions of Sick

1. Measurement Sensors and sensor systems from SICK measure dimensions, profiles, volumes, distances, speeds, and filling levels to ensure smooth processes. 2. Detection SICK sensors can detect the presence and quality of various objects as well as the quality of consumer products to meet the needs of ...

Sick Sensors – Where can ultrasonic sensors not be used? Sick Sensors – Where can ultrasonic sensors not be used?

(1) When the target to be measured is not perpendicular to the transducer of the sensor. This is because the target of the ultrasonic test must be within an angle of no more than 10° perpendicular to the sensor. (2) When a small beam diameter is required. Because the diameter of the general ultrasonic beam is ...

Sick Sensors – the solution to linear displacement sensor failures Sick Sensors – the solution to linear displacement sensor failures

1. If the electronic ruler has been used for a long time, and the seal has been aged, and there are many impurities mixed with it, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers keep jumping. At this time, it can be said that the electronic ...

Sick sensor - the detection procedure of the sensor, the precautions in the detection process Sick sensor - the detection procedure of the sensor, the precautions in the detection process

The detection procedure of the sensor 1. Symptom Judgment: Infer the location where the malfunction may occur. 2. Decoder detection: Confirm whether the suspected sensor has a fault code in the decoder, and strengthen the judgment in the data stream. 3. Inspection around the sensor: In case of ...

Parameter settings for the Sigg distance sensor Parameter settings for the Sigg distance sensor

1. Set to "Surface" to measure the distance from the first surface within the sensor's detection range. This setting is available for all sensor heads. 2. Set to Glass Thickness to measure the distance from the front to the back of a transparent object, such as glass. This means that it has been measured with the sensing ...

An introduction to the classification of Sick sensors An introduction to the classification of Sick sensors

1. Industrial sensors The SICK industrial sensor portfolio includes the widest range of photoelectric sensors, fiber optic amplifiers, color mark sensors, proximity sensors, magnetic cylinder sensors, and measuring light curtains in the automation sector, which are mainly used for: recording, counting, classifying, and positioning objects.

Sick Sensors – Precautions for the use of displacement sensors Sick Sensors – Precautions for the use of displacement sensors

1. There are many types of displacement sensors, and the measurement accuracy, service life, response frequency and applicable occasions of sensor products designed with different principles will be slightly different. Appropriate displacement sensor products should be selected according to the on-site installation and measurement requirements. 2. The measurement range of the displacement sensor is one ...

Introduction to the advantages and disadvantages of Sick sensors Introduction to the advantages and disadvantages of Sick sensors

1. Advantages (1) Germany SICK flow sensor can be used to measure industrial conductive liquids or slurries. (2) No pressure loss. (3) The measuring range is large, and the diameter of the electromagnetic flow transmitter is from 2.5mm to 2.6m. (4) Germany Sick SICK traffic transmission ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383