Sick Sensors – How to use the Contrast Sensor
1. Wiring There are 4 outgoing wires of the sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. The lines are not ...
|
|
Sick Sensors – Where can ultrasonic sensors not be used?
(1) When the target to be measured is not perpendicular to the transducer of the sensor. This is because the target of the ultrasonic test must be within an angle of no more than 10° perpendicular to the sensor.
(2) When a small beam diameter is required. Because the diameter of the general ultrasonic beam is ...
|
|
Sick Sensors – Applications for thermistor sensors
1. Thermistor sensor temperature measurement
Thermistor sensors used to measure temperature are generally simple in structure and inexpensive. Thermistors without an outer protective layer can only be used in dry places; Hermetically sealed thermistors are not afraid of moisture erosion and can be used in harsh rings.
|
|
Sick sensors – the working methods and characteristics of fork photoelectric sensors and their differences
How fork photoelectric sensors work:
Placing an optical transmitter and a receiver facing each other on either side of a slot is a fork photoelectric. The luminaire emits infrared or visible light, and the light receiver receives the light in an unobstructed condition. But when the detected object passes through the trough ...
|
|
Sick Product Sharing | IMM redefines proximity sensor applications in confined spaces
In the application of inductive proximity sensors, customers are often trapped by the lack of space to install, and the small parts are too small to be effectively detected, and the IMM miniature proximity sensor provides a variety of application solutions in this type of application.
IMM miniature proximity sensor with a richer ...
|
|
Adjustment method of Sick sensor NT6-03022
1. Self-regulation. At the beginning of use, please check whether the switch itself is defective and whether the appearance is defective.
2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...
|
|
Sick Sensors – A detailed introduction to the principles of the five common pressure sensors
1. Piezoelectric pressure sensor
Based on the piezoelectric effect, electrical components and other machinery are used to convert the pressure to be measured into electricity, and then perform related measurement work. Piezoelectric sensors can only be used for dynamic measurements. Host...
|
|
Sick TMx22 tilt sensor – smaller, smarter
The miniaturization, integration, and intelligence of sensors are the main trends of industrial development, and the increasing demand for small and integrated smart chips in industrial scenarios also provides better means for equipment integration and intelligence.
Sick is also deeply aware of the small size of the large ...
|
|
Sick Sensors – Common classifications and connections for RTD sensors
1. Platinum thermal resistance
The platinum metal is used as the temperature sensing element, and then together with the inner lead and the protective tube, the platinum thermal resistance temperature sensor is formed. It is also often connected to external measurement circuits, controls, and mechanisms to form a temperature sensor.
This sensor has two main ...
|
|
LiDAR LOC | An embedded positioning software for AGVs/AMRs
Product Introduction
LiDAR LOC is an embedded positioning software for AGVs/AMRs. Maps can be used to create usable maps based on the environmental information collected by LiDAR, and mobile positioning data for AGVs and AMRs is provided in the form of UDP data output (x, y, and deflection angles). CAD compliance is also available.
|
|
Sick Sensors - Analysis of common fault codes for fiber optic sensors
1. Alarm code E401
E401 is one of the common fault codes of fiber optic sensors, which indicates that the fiber optic sensor has detected that the fiber is cracked or bent. This problem can usually be dealt with by replacing the fiber or adjusting the fiber installation orientation.
2. Alarm code E402
...
|
|
Full-process baggage tracking solution for Sick Airport
The important indicator of airport baggage tracking is: accurate and timely delivery of baggage, and SICK has a rich and complete solution in the field of air baggage reading.
This article will take you to take a detailed look at SICK's solutions for the whole process of baggage tracking and traceability.
The core of the system
Model...
|
|
A simple explanation and how to use the SICK color scale sensor
The SICK color mark sensor detects a wide range of labels, even if there are subtle differences in the background color, and the processing speed is fast. Automatically adapts to wavelength and is able to detect small differences in grayscale values, regardless of the mixed color of the label and background.
SICK color code ...
|
|
Where are the main applications of Sick Sensors – Laser Distance Sensors?
Position monitoring of moving objects;
Railway catenary survey, building limit survey;
Measurement of objects that are not suitable for access;
industrial automation and intelligent production management;
Automobile speed and traffic statistics;
Industrial monitoring signal trigger control;
Tower crane ...
|
|
Applications of Sick photoelectric sensors
Photoelectric sensors that use optoelectronic components as sensitive components have a wide variety of types and applications. According to the nature of the output of photoelectric sensors, they can be divided into two categories:
(1) The photoelectric measuring instrument made by converting the measured into a continuously changing photocurrent, can be used to measure the intensity of light and the object ...
|
|
Sick Sensors - Common faults and treatment methods of photoelectric sensors
1. First of all, the front face of the photoelectric sensor must be parallel to the surface of the workpiece or object to be detected, so that the conversion efficiency of the photoelectric sensor will become high.
2. When installing and welding, the small distance between the root of the pin of the photoelectric sensor and the pad shall not be less than 5 mm, otherwise ...
|
|
Sick 3D cameras help the field of refractory bricks
With the continuous advancement of the wave of industrial upgrading in the metallurgical industry, the refractory brick industry in the subdivided field has also ushered in a new opportunity, machine vision as the core technology of industrial automation has also been fully applied, and the 3D camera of Sick has shown excellent performance in the field of refractory bricks.
Refractory bricks are abbreviated ...
|
|
Sick 3D vision gluing application case in shoe soles
Traditional sole gluing needs to be done manually, and this process generally has a high temperature and fast toxicity volatilization. However, with the development of Industry 4.0, outdated equipment, rising costs, poor production environment, and shortage of personnel in this type of work have become important reasons for the upgrading and transformation of this process. SICK in partnership ...
|
|
Sick Deep Learning SensorApp Intelligent Inspection Plus released
Based on the InspectorP series of Sick 2D smart cameras, the deep learning SensorApp Intelligent Inspection Plus was officially launched, adding "Anomaly detection" and "Classification ...
|
|
Sick sensor - the working principle and application of color sensor
What are the applications of color sensors?
1. Discrete photodiode with color filter
The traditional way to sense color is to use a structure that combines three to four photodiodes on a single chip, with red, green, and blue color filters placed on the surface of the photodiodes. Independent...
|