Sick launched a new diffuse reflection long array photoelectric sensing

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

The logistics industry has always been a strong area for SICK, in response to the detection of various types of goods on different conveyor lines and the diverse needs of customers, SICK has launched a series of photoelectric sensors such as G6, Z18, W16, W26 and Ray26 - which can stably detect cartons, baskets, uneven appearance, transparent bottles, laminated packaging and flexible packaging food and drugs.

However, almost all of the above solutions are retroreflective optoelectronic products, which requires customers to install additional or even customized brackets, and regularly clean and maintain the reflectors and sensors.

In response to these situations, SICK has launched a new Roller Sensor Bar (RSB).

1. Product overview
Sick launched a new diffuse reflection long array photoelectric sensing


Features & Parameters

Product length: 200-1200mm

Light source type: infrared

Number of spots: 2-8

Beam Distance (MDO): ≥50mm

Output Category: PNP/NPN/Push-Pull

Connection type: 4-pin loose wire/M12 4-pin/M8 4-pin/RJ12/RJ9, etc

Detection distance: 2-300mm(90%)

Operating temperature: -40 - +60°C

2. Product features

Unlike mirror-reflective optoelectronics, which requires calibration and debugging, RSB long array optoelectronics can be plug-and-play without additional debugging.

After being fixed under the conveyor belt, it can detect and identify black objects, irregular objects, highly reflective objects and transparent objects.

The maximum detection distance can reach 300mm
Sick launched a new diffuse reflection long array photoelectric sensing


Customers do not need to build their own brackets, SICK provides four brackets suitable for different conveyor line structures, with the spring buckles at both ends of the RSB, which can be easily installed under the roller conveyor line and in the belt conveyor line gap.

3. Typical application scenarios

3.1 Roller conveyor line
Sick launched a new diffuse reflection long array photoelectric sensing

Installed in the gap of the drum, no teach-in, no additional bracket required

Stable detection of envelopes, parcels, cartons, pallets

The maximum detection distance is 300mm

3.2 Belt conveyor line
Sick launched a new diffuse reflection long array photoelectric sensing

Diffuse photoelectric, no need for mirrors and additional brackets

Plug and play, greatly reduce the cost of commissioning

Reliable detection of irregular and thin objects

3.3 Warehouses and shuttles
Sick launched a new diffuse reflection long array photoelectric sensing

Installed under the drum without additional brackets and commissioning

Perform in-place inspection of the shuttle

Limit detection of goods in the shelf

4. Conveyor line detection sensor scheme

So far, SICK has launched a variety of photoelectric sensors to meet the detection needs of roller conveyor lines and belt conveyor lines, so how should you choose for different applications?

The table below serves as a simple reference for different product families to choose from depending on the application and environmental requirements, and the corresponding product series also includes a wide range of products with different output types and wiring methods.
Sick launched a new diffuse reflection long array photoelectric sensing


Sick launched a new diffuse reflection long array photoelectric sensing

Source: Sick SICK, Germany

More on that
Sick sensors – the future of photoelectric sensors Sick sensors – the future of photoelectric sensors

Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals. Photoelectric sensors are generally composed of three parts: light source, optical path and optoelectronic components. The measured change is converted into a change in the optical signal, and then the optoelectronic component is used to further ...

Sick Sensors – Infrared Sensor Installation Requirements and Precautions Sick Sensors – Infrared Sensor Installation Requirements and Precautions

Infrared sensor installation requirements: 1. Infrared sensors are usually set up in areas where intruders may enter or where high-value items are stored, such as the living room, master bedroom, corridor or corridor of a general family; In general, companies usually set up sensors in computer rooms, corridors, warehouses, etc.

Sick Sensors – Precautions for the use of color mark sensors Sick Sensors – Precautions for the use of color mark sensors

1. Be sure to check whether the power supply used is in line with DC12-24V±10%, and the maximum is not more than 40V, otherwise the photoelectric switch may be damaged. 2. In order to ensure high stability detection, it is necessary to ensure that two points are achieved: first, the detection distance meets the specified rated detection distance, such as the detection distance is 12±2mm ...

Sick Sensor – The difference between a photoelectric sensor and a light sensor Sick Sensor – The difference between a photoelectric sensor and a light sensor

1. Different definitions: A light sensor is generally a device that can sensitively sense light energy from ultraviolet light to infrared light and convert the light energy into an electrical signal. Photoelectric sensors are sensors that use an optoelectronic element as a detection element. It first converts the measured change into light ...

The main characteristics and usage methods of SICK sensors The main characteristics and usage methods of SICK sensors

Key Characteristics of SICK Sensors (Displacement Sensor Principle) Nominal Resistance: The value of resistance indicated on the potentiometer. Promise error: The ratio of the nominal resistance to the practical resistance to the nominal resistance is the resistance deviation, which indicates the accuracy of the potentiometer. Promise errors are usually made in the ± 20 ...

Adjustment method of sensing distance of Sick photoelectric sensor Adjustment method of sensing distance of Sick photoelectric sensor

1. Find the screw at the end of the switch, twist it clockwise to adjust it far, and twist it counterclockwise to adjust it closer. 2. It can increase the intensity of the light source. 3. Improve the sensitivity of the switch sensor. 4. It can also be adjusted according to the instructions for use. ...

Introduction to the functions of various types of Sick sensors Introduction to the functions of various types of Sick sensors

1. Industrial sensors The SICK industrial sensor portfolio includes the widest range of photoelectric sensors, fiber optic amplifiers, color mark sensors, proximity sensors, magnetic cylinder sensors, and measuring light curtains in the automation sector, which are mainly used for: recording, counting, classifying, and positioning objects.

The application of Sick 3D vision in the steel industry The application of Sick 3D vision in the steel industry

With the rapid development of industrial automation in recent years, machine vision, as a smart brain endowed with "eyes" to machines, has been widely used in various fields of intelligent manufacturing. In the context of the rapid penetration of artificial intelligence in the Internet and emerging industries, traditional industries are also constantly promoting intelligent ...

Introduction to the functions and characteristics of Sick sensors Introduction to the functions and characteristics of Sick sensors

1. At present, SICK pressure sensors can be used in combination with computers and instruments to improve operation and reduce errors. The human-machine dialogue function is the main feature of SICK pressure sensors, and the display device and input keyboard equipped with it become the medium for human-machine dialogue. 2. SICK pressure sensing ...

Introduction to the characteristics of the Sick sensor - laser distance sensor Introduction to the characteristics of the Sick sensor - laser distance sensor

1. Wide measurement range and fast response; 2. Reflector is not required for long-distance measurement; 3. High measurement accuracy and large range; 4.905 nm safety laser is not harmful to human eyes; 5. Small size, easy to install and debug; 6. On-line continuous measurement to reach unmanned ...

How to set the parameters of the SICK UM30 fiber optic sensor? How to set the parameters of the SICK UM30 fiber optic sensor?

1. Connect the device: connect the power supply and electrical signal to the sensor, connect the output interface to the PLC, connect RS232 to the computer, generally use RS232, but also change to other control methods, such as CAN, RS485 and so on. 2. Software installation: Open the laptop, install ...

Sick Sensors – the solution to linear displacement sensor failures Sick Sensors – the solution to linear displacement sensor failures

1. If the electronic ruler has been used for a long time, and the seal has been aged, and there are many impurities mixed with it, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers keep jumping. At this time, it can be said that the electronic ...

Sick Sensors – Precautions for the use of pressure sensors Sick Sensors – Precautions for the use of pressure sensors

1. The sensor should be handled gently, especially for the small range sensor with aluminum alloy material as the elastomer, any impact or drop caused by vibration is likely to cause a large output error. In addition, it is necessary to protect the sensor outlet head and not to break it 2. Design loading ...

Sick Sensors – Common classifications and connections for RTD sensors Sick Sensors – Common classifications and connections for RTD sensors

1. Platinum thermal resistance The platinum metal is used as the temperature sensing element, and then together with the inner lead and the protective tube, the platinum thermal resistance temperature sensor is formed. It is also often connected to external measurement circuits, controls, and mechanisms to form a temperature sensor. This sensor has two main ...

Sick Sensors – How to use the Contrast Sensor Sick Sensors – How to use the Contrast Sensor

1. Wiring There are 4 outgoing wires of the sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. The lines are not ...

Sick sensors – the basic components of infrared sensor systems and their functions Sick sensors – the basic components of infrared sensor systems and their functions

1) The target to be measured: the infrared system is set according to its infrared radiation characteristics; 2) Atmospheric attenuation: When the infrared radiation of the object to be measured passes through the atmosphere, it will be affected by a variety of substances and the attenuation phenomenon occurs; 3) Optical receiver: used to receive part of the infrared radiation and ...

Sick Sensors – Applications of Photoelectric Sensors Sick Sensors – Applications of Photoelectric Sensors

1. Application of photoelectric sensor in high-voltage and high-current testing In recent years, the use of optical equipment for high-voltage and high-current measurement has developed rapidly in the power system, and many new photoelectric sensor systems have been put into on-site operation, bringing many convenient measures for the monitoring of high-voltage and high-current.

The GLS621, a new member of the Sick AGV/AGC navigation sensor family The GLS621, a new member of the Sick AGV/AGC navigation sensor family

As a special sensor for the two-dimensional code positioning and navigation market, GLS621 is mainly used in warehousing AGVs or warehouse handling robots based on the principle of inertial two-dimensional code navigation.

Sick Sensor - Introduction to the 7 performance indicators of the sensor Sick Sensor - Introduction to the 7 performance indicators of the sensor

1. Linearity: refers to the degree to which the actual relationship curve between the output and input of the sensor deviates from the fitting straight line. Defined as the ratio of the maximum deviation between the actual characteristic curve and the fitted line over the full scale range to the full-scale output. 2. Sensitivity: Sensitivity is the sensor ...

SICK introduces the magnetic rotation sensor MAS SICK introduces the magnetic rotation sensor MAS

In the digitalization stage, the first step of the development path of Industry 4.0, Sick is committed to the design and development of intelligent sensors, aiming to lay a solid hardware foundation for digital transformation. Now, Sick has added a new member to the family of smart sensors – the magnetic corner sensor MAS. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top