Sick Sensors – Where can ultrasonic sensors not be used?

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

(1) When the target to be measured is not perpendicular to the transducer of the sensor. This is because the target of the ultrasonic test must be within an angle of no more than 10° perpendicular to the sensor.

(2) When a small beam diameter is required. This is because the diameter of the ultrasonic beam is 0.76 cm when it is 2 m away from the sensor.

(3) Occasions where visible light spots are required for position calibration.

(4) Windy occasions.

(5) Vacuum occasions.

(6) Occasions with large temperature gradients. This is because there will be a change in the speed of sound.

(7) Occasions that require a quick response.
Sick Sensors – Where can ultrasonic sensors not be used?

More on that
Sick Sensors - Classification of RTD Sensors and Their Characteristics and Uses Sick Sensors - Classification of RTD Sensors and Their Characteristics and Uses

1. NTC RTD Sensor: Features: This kind of sensor is a negative temperature coefficient sensor, that is, the sensor resistance decreases with the increase of temperature; Application: NTC thermistors are commonly used as temperature measurement tools on the air side and medium side in automotive thermal management systems, such as evaporation.

Sick sensor - the classification and principle of distance sensors Sick sensor - the classification and principle of distance sensors

Principle of ultrasonic distance sensor: Ultrasonic waves have a great ability to penetrate liquids and solids, especially in solids that are opaque to sunlight, and it can penetrate to a depth of tens of meters. Ultrasonic waves will produce significant reflections when they encounter impurities or interfaces, forming reflections into echoes, which can produce ...

Sick Case Sharing | Robot automatic welding and spraying guidance Sick Case Sharing | Robot automatic welding and spraying guidance

With the rapid development of "Made in China" to "Made in China", intelligent equipment and other technologies have been widely used in various fields, among which the degree of intelligence in steel structure construction is also getting higher and higher. In the intelligent construction of steel structures, welding and spraying are indispensable process links, in which ...

Sick Sensors – How to use the Contrast Sensor Sick Sensors – How to use the Contrast Sensor

1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...

Sick Sensors – The system composition of ultrasonic sensors Sick Sensors – The system composition of ultrasonic sensors

Transmitter: An oscillator (usually ceramic, about 15 mm in diameter) vibrates to generate ultrasonic waves and radiate them into the air. Receiver: When the oscillator receives the ultrasonic wave, it generates the corresponding mechanical vibration according to the ultrasonic wave and converts it into electrical energy as the output of the receiver. ...

Sick sensor - the detection procedure of the sensor, the precautions in the detection process Sick sensor - the detection procedure of the sensor, the precautions in the detection process

The detection procedure of the sensor 1. Symptom Judgment: Infer the location where the malfunction may occur. 2. Decoder detection: Confirm whether the suspected sensor has a fault code in the decoder, and strengthen the judgment in the data stream. 3. Inspection around the sensor: In case of ...

Sick Sensors – Installation Requirements for RTD Sensors Sick Sensors – Installation Requirements for RTD Sensors

1. In order to have sufficient heat exchange between the measuring end of the RTD and the medium to be measured, the location of the measuring point should be reasonably selected, and the installation of RTD near the valve, elbow, pipe and equipment should be avoided as much as possible. 2. The thermal resistance with a protective sleeve has heat transfer and heat dissipation loss, in order to reduce the ...

Sick Sensors – Common classifications and connections for RTD sensors Sick Sensors – Common classifications and connections for RTD sensors

1. Platinum thermal resistance The platinum metal is used as the temperature sensing element, and then together with the inner lead and the protective tube, the platinum thermal resistance temperature sensor is formed. It is also often connected to external measurement circuits, controls, and mechanisms to form a temperature sensor. This sensor has two main ...

What are the features of Sick Sensors – Proximity Sensors? What are the features of Sick Sensors – Proximity Sensors?

(1) Since the inspection can be carried out in a non-contact manner, it does not wear or damage the object to be inspected. (2) Since the contactless output method is adopted, the life extension (except for the magnetic type) is made of semiconductors, and the life of the docking point is not affected. (3) It is not the same as the light detection method.

Sick boutique makes a comeback: capacitive proximity sensors Sick boutique makes a comeback: capacitive proximity sensors

Are you still having a headache about detecting the presence or absence of objects? Are you still bothered by checking the liquid level? Are you still troubled by the limited installation of application scenarios? Today, SICK is back with the secret weapon of substance detection: capacitive proximity sensors.   This capacitive sensing ...

LiDAR LOC | An embedded positioning software for AGVs/AMRs LiDAR LOC | An embedded positioning software for AGVs/AMRs

Product Introduction LiDAR LOC is an embedded positioning software for AGVs/AMRs. Maps can be used to create usable maps based on the environmental information collected by LiDAR, and mobile positioning data for AGVs and AMRs is provided in the form of UDP data output (x, y, and deflection angles). CAD compliance is also available.

Sick Sensors - Infrared sensors are classified according to the way they are emitted Sick Sensors - Infrared sensors are classified according to the way they are emitted

Depending on the way of transmission, infrared sensors can be divided into two types: active and passive. 1. Active infrared sensor The transmitter of the active infrared sensor emits a modulated infrared beam, which is received by the infrared receiver, thus forming a warning beam composed of an infrared beam ...

SICK introduces the magnetic rotation sensor MAS SICK introduces the magnetic rotation sensor MAS

In the digitalization stage, the first step of the development path of Industry 4.0, Sick is committed to the design and development of intelligent sensors, aiming to lay a solid hardware foundation for digital transformation. Now, Sick has added a new member to the family of smart sensors – the magnetic corner sensor MAS. ...

Introduction to the performance of the W4F series of miniature intelligent photoelectric sensors from sick Introduction to the performance of the W4F series of miniature intelligent photoelectric sensors from sick

Friends who pay attention to Sick will not be unfamiliar with the W4-3 series products, this classic mini photoelectric is widely praised by the industry for its excellent set pressing function and diverse optical functions. Whether the object is a lubricated and reflective mobile phone surface, a wrinkled and dark food packaging bag, or ...

Sick's 3D vision product Ruler series has been newly upgraded! Sick's 3D vision product Ruler series has been newly upgraded!

Recently, Sick's 3D vision product Ruler series has been newly upgraded! The new products Ruler3002, Ruler3004 and Ruler3010 are officially available today!   01. Product characteristics • Contour point upgrade: up to 3200 Data points/Profile • Ultra-high scanning speed ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.

Sick Sensors – The lead method for RTD sensors Sick Sensors – The lead method for RTD sensors

1. Two-wire system: the way to connect a wire at both ends of the thermal resistance to draw out the resistance signal is called the two-wire system: this lead method is very simple, but because there must be a lead resistance r for connecting the wire, the size of R is related to the material and length of the wire, so this lead method is only applicable to ...

Sick Sensors - Classification and detailed introduction of temperature sensors Sick Sensors - Classification and detailed introduction of temperature sensors

According to the measurement method, it can be divided into contact type and non-contact type 1。 The detection part of the contact: the contact temperature sensor is in good contact with the measured object, also known as the thermometer The thermometer achieves thermal equilibrium by conduction or convection, so that the indicated value of the thermometer can directly represent the ...

Sick intelligent sensors help the intelligent transformation of the pharmaceutical industry Sick intelligent sensors help the intelligent transformation of the pharmaceutical industry

With the obvious trend of population aging and the innovation and development of the medical and pharmaceutical industry, it can be expected that the demand for pharmaceutical products in China will continue to grow rapidly, and it is estimated that the industry scale will reach 2.15 trillion yuan by 2024. The huge market size also means more fierce market competition, plus ...

Sick Sensor – The difference between an infrared sensor and a laser sensor Sick Sensor – The difference between an infrared sensor and a laser sensor

Infrared sensors: Sensors that take advantage of the physical properties of infrared rays to make measurements. Infrared light is also known as infrared light. The infrared sensor does not have direct contact with the measured object during measurement, and the anti-interference performance is poor, so the lens needs to filter the infrared light before measurement, and it needs to be calibrated regularly. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top