1. No-load energizing test of Mitsubishi inverter.

1. Ground the ground terminal of the Mitsubishi inverter.

2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch.

3. Check whether the factory display window of the Mitsubishi inverter is normal, if it is incorrect, it should be reset, otherwise it will be returned.

4 Understand the operation keys of the inverter. The general inverter has 6 buttons, such as RUN, STOP, PROG, DATAPENTER, UP and ▲, and DOWN, and the definition of the operation keys of different inverters is basically the same.

                               Mitsubishi inverter pre-use debugging method

2. Mitsubishi inverter with motor runs without load

1. Set the power and number of poles of the servo motor, and consider the working current of the inverter.

2. Set the maximum output frequency, fundamental frequency, and torque characteristics of Mitsubishi inverter. The general inverter is equipped with a number of VPf curves for users to choose, and users should select the appropriate VPf curves according to the nature of the load when using.

3. Set the Mitsubishi inverter to the built-in keyboard operation mode, press the run key and stop button, and check whether the motor can start and stop normally.

4. Understand the maintenance code when the Mitsubishi inverter is operating in a malfunction, investigate the factory value of the thermal maintenance relay, investigate the set value of overload maintenance, and be able to correct it if necessary. The user of the Mitsubishi inverter can set the electronic thermal relay function of the Mitsubishi inverter according to the instruction manual of the Mitsubishi inverter.

3. Mitsubishi inverter with load test operation

1. Manually operate the operation stop button of the Mitsubishi inverter panel, investigate the motor operation and stop process and the display window of the inverter to see if there is any abnormal phenomenon.

2. If there is an overcurrent maintenance action of the Mitsubishi inverter during the process of starting the P stop motor, the deceleration time of P should be set from the beginning to speed up. The acceleration of the motor during acceleration and deceleration depends on the acceleration torque, while the frequency change rate of the Mitsubishi inverter during the start and braking process is set by the user.

More on that
Mitsubishi Electric Europe Ltd. acquires AQS, a Sweden air conditioning distributor Mitsubishi Electric Europe Ltd. acquires AQS, a Sweden air conditioning distributor

TOKYO, April 2, 2020 - Mitsubishi Electric Corporation (TSE: 6503) announced today that its European subsidiary, Mitsubishi Electric Europe Ltd., acquired all the shares of AQS PRODUKTER AB, a Sweden company in the comfort, craft industry, on April 1.

Mitsubishi PLC and computer communication setup method Mitsubishi PLC and computer communication setup method

After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings". 1. Connect the Mitsubishi PLC to the computer first. 2. Right-click on "My Computer" and select "Handle"...

Mitsubishi Step Ladder Instruction [STL], [RET] usage example Mitsubishi Step Ladder Instruction [STL], [RET] usage example

Step Instruction (STL) is an instruction that uses internal software components to control the process step on top of the sequential control program. A step-to-back instruction (RET) is an instruction that is used to return to the main program (bus) after the state (S) process is completed. ...

Mitsubishi inverter encountered problems and solutions Mitsubishi inverter encountered problems and solutions

1. If you want to use the inverter to drive the motor with a capacitor to improve the power factor, but the motor does not move, please explain the reason. The current flowing into the inverter is used to improve the power factor, but the capacitor cannot be started because its charging current causes the inverter overcurrent (OCT), as a countermeasure, ...

Explanation of Mitsubishi pIc source type and drain type Explanation of Mitsubishi pIc source type and drain type

The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal. The general input points are ...

Mitsubishi PLC Step Instruction Instructions for use Mitsubishi PLC Step Instruction Instructions for use

1. Step Instruction (STL/RET) Step instruction is an instruction that is specially planned for sequential control. In the field of industrial control, many control processes can be completed by sequential control, and the use of step instructions to complete sequential control is not only convenient to complete, but also easy to read and modify. There are two in the FX2N ...

Mitsubishi Q Series PLC and GX Works2 connection method Mitsubishi Q Series PLC and GX Works2 connection method

01 USB connection USB connection requires a device USB driver, generally after installing GX Works2 software, it will automatically install the driver, but a single time due to antivirus software or system reasons, may not be installed, then we need to manually drive the device to the accounting machine. The specific device method we ...

Mitsubishi servo motor is now commonly used Mitsubishi servo motor is now commonly used

Torque control: Torque control is based on external simulation imitation typing or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load of the motor shaft is less than 2.5Nm, then when ...

Classification of Mitsubishi touch screens Classification of Mitsubishi touch screens

At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors. 1. Resistive contact screen The screen body of the resistive contact screen ...

MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT

With the spread of industrial robots in the production site, more and more on-site issues need to be solved, such as the need for more robot programming engineers, which increases the human cost; The teaching is complicated, which increases a lot of non-production time; Set up guardrails to increase the cost of space and installations; Robot...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...

A brief description of Mitsubishi's PLC network structure A brief description of Mitsubishi's PLC network structure

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Whereas...

Review and comparison of Mitsubishi PLC control inverter methods Review and comparison of Mitsubishi PLC control inverter methods

1. The switching signal of PLC controls the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...

Mitsubishi servo about the selection of robot methods Mitsubishi servo about the selection of robot methods

When evaluating which process is suitable for which approach in the production environment, it is important to carefully consider the problem you want to deal with and consider all the costs that the robot can save: cutting waste, improving efficiency, improving yield, improving safety, or reducing labor costs. These costs ...

Mitsubishi FX series PLC fault diagnosis method Mitsubishi FX series PLC fault diagnosis method

1. Power indication (LED indication) When power is supplied to the Mitsubishi PLC root unit, the [POWER] LED indicator light installed on the surface of the root unit turns on. If the power supply is closed but the [POWER] LED does not illuminate, please acknowledge the power wiring. In addition, if the same power supply has a drive sensor, etc. ...

Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM

Power semiconductor module for 40kW class commercial air conditioner Expansion of the "6th Generation 1200V Large DIPIPM" product lineup Mitsubishi Electric Corporation will sell the power of inverters that drive commercial air conditioners and other products on August 30.

The matching relationship between the inverter and the motor - Mitsubishi The matching relationship between the inverter and the motor - Mitsubishi

It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...

Mitsubishi inverter control mode Mitsubishi inverter control mode

According to the classification of the main circuit operation mode, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; According to the classification of operating principles, it can be divided into V/f control frequency conversion ...

Mitsubishi PLC communication detection steps Mitsubishi PLC communication detection steps

When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port. ...

Methods for shortening the scanning cycle of PLC programs – Mitsubishi Methods for shortening the scanning cycle of PLC programs – Mitsubishi

1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers. 2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S; 3. Try to prevent the transformation of data types, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top