With the spread of industrial robots in the production site, more and more on-site issues need to be solved, such as the need for more robot programming engineers, which increases the human cost; The teaching is complicated, which increases a lot of non-production time; Set up guardrails to increase the cost of space and installations; The connection and setting of the robot and the peripheral equipment are complex, which increases the device and protection time; In addition, it is necessary to ensure a safe distance between the robot and the workers at the production site.
On May 20, 2020, Mitsubishi Electric simultaneously announced a new product, the collaborative robot MELFA ASSISTA, in Japan and China, which perfectly addresses many traditional robot application field issues. The new cobot arm is equipped with a dedicated operation button and an LED to display the status of the robot, and is equipped with the programming software "RT VisualBox") that can easily introduce and debug the robot's programming equipment, further improving the production power at the production site, reducing the total cost of ownership (TCO) and contributing to solving the new problem of maintaining a safe separation between the robot and the operator at the production site.
Assist+A=Assista
Anyone is simple enough for anyone to use
Anytime is instantaneous, and the automation is perfect
Anywhere can be equipped with mobile devices such as AGVs without space constraints
Advantage 1: Programming is simpler
The newly developed programming thing RT VisualBox can easily create a program of the robot system through simple and intuitive operation using block diagrams, making the setup and debugging of this robot easier.
Peripheral devices such as robot grippers and cameras are easier to connect and set up, and proven robot grippers and cameras can be connected and set up more easily through RT VisualBox. The number and scope of partners is constantly expanding.
Reduction of man-hours for program development, planning, and system protection management
Advantage 2: Dedicated teaching operation button
Through the special operation button mounted on the robot arm, the teaching work of the robot (recording and reproducing the action) is completed, and the teaching pendant is no longer required.
The number of operations required for teaching work is reduced to a minimum, and even unskilled workers can easily complete the setup in a short time.
Advantage 3: LED light display status
The LED light mounted on the robot arm shows the operating status. Workers around the robot can grasp the robot's condition at a glance and create a co-located work environment.
There is no longer a need for special peripherals to show the operation status of the robot.
MELFA ASSISTA, A SMART PRODUCTION CENTER DEVICE
Mitsubishi Electric's new cobot MELFA ASSISTA complies with the global standard ISO 10218-1 General Safety Requirements for Industrial Robots (Part 1) and the technical specifications for ISO/TS 15066 collaborative robots. In addition, a collaborative robot using NSF H1 certified grease for food machinery has been added. In line with the world standard ISO 10218-1 and ISO/TS 15066, it is possible to build a system that eliminates the need for robot safety guardrails based on the customer's risk assessment, saving space.
MELFA ASSISTA fully considers the on-site application in the planning, which facilitates better cooperation between the on-site operators and robots around the robot, safely and effectively improves the production power, reduces TCO, and builds an automated and intelligent production unit centered on industrial robots, so as to help customers improve their comprehensive value.
|
More on that
|
The role of PLC power module - Mitsubishi
Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...
|
|
Mitsubishi servo motor shaft failure causes and solutions
1. The cause of the failure
(1) Unreasonable mechanical design leads to excessive radial load force;
(2) The load side is stuck, or the moment of severe overload;
(3) The motor and reducer are not centered when installed;
2. Fault cleaning
...
|
|
Mitsubishi servo system failure problem
The origin position is incorrect, and the encoder debugs/zeros the bit
Replacement bearings, bearing groove wear, rotor cracking, shaft cracking
Gear groove wear
The magnet bursts steel, the magnet falls, gets stuck and doesn't move
Encoder wear, code ...
|
|
Mitsubishi PLC selection 5 elements
Mitsubishi PLC selection - element 1: IO points
The number of ZUI IOs that can be accessed by the Mitsubishi PLC control system.
Mitsubishi PLC FX series now commonly used basic unit host is: FX1SFX1N, FX1NC, FX2N, FX2NC, FX3U. FX3UCFX3G, FX5U, 9 series.
...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation.
...
|
|
Mitsubishi PLC writes the holding circuit
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed through the insistence circuit to press the button to insist on the output, similar to the self-locking in the electrical diagram. Let's take Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Mitsubishi servo motor types and advantages
1. DC servo
The structure is simple and easy to operate. However, considering the actual operation, the DC servo motor has introduced mechanical equipment for reversing installation, which increases the cost, has many problems, and is inconvenient to maintain, and often interferes with the production and manufacturing due to the sparks of carbon brushes, and electromagnetic interference will occur. Combine...
|
|
Special function module of the Mitsubishi PLC FX series
The communication module of PLC is used to complete the communication with other PLCs, other intelligent control equipment or computers. The following is a brief introduction to the FX series communication function shields, adapters and communication modules.
(1) Communication expansion ...
|
|
Mitsubishi PLC main maintenance and overhaul content points
The main content of the protection and maintenance of Mitsubishi PLC
Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...
|
|
Mitsubishi inverter FR-E024-0.75K repair
Type: FR-E024-0.75K
Fault: The boot cannot be started
Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...
|
|
Features of the MELSEC iQ-R series of programmable controllers
1. Routine control is consistent with safety control
In the MELSEC-QS series, it is necessary to prepare a system for conventional control and a system for safety control. With the MELSEC iQ-R series of safe programmable controllers, it is possible to combine conventional and safe control into a single system.
Quiet...
|
|
Mitsubishi servo maintenance failure analysis
Major Failures and Analysis:
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
...
|
|
The choice of industrial tablet case – Mitsubishi
Tablet PC can often be seen in today's daily life, it can be brought stronger, but also more popular with us, industrial tablet PC is gradually widespread, because industrial use will cause Tablet PC is very simple damage, so generally will use maintenance covers, so ...
|
|
The difference between the performance of Mitsubishi servo motor and stepper motor
First, the control accuracy is different
The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors with smaller step angles after subdivision. Communicate the control of servo motor ...
|
|
Mitsubishi low-power Z024 series inverter failure OC cause
(1) Aging of the drive circuit
Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running.
( ...
|
|
The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules
The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment.
...
|
|
Methods for shortening the scanning cycle of PLC programs – Mitsubishi
1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers.
2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S;
3. Try to prevent the transformation of data types, ...
|
|
The difference between a Mitsubishi servo motor and a stepper motor
First, the control accuracy is different
The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors that have a smaller step angle after being subdivided. Communicate the control of servo motor ...
|
|
Mitsubishi PLC communication detection steps
When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port.
...
|
|
How to deal with Mitsubishi PLC failures - Mitsubishi
01. Base system problem
In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base.
2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...
|
|