Mitsubishi PLC communication detection steps

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port.

                                  Mitsubishi PLC communication detection steps

The following means that you can communicate

  C:\ping 192. 168. 0. 2

  Reply from 192. 168. 0. 2:bytes = 32 time<10ms TTL=32 ;

The following means that communication is not possible

  C:\>ping 192. 168. 0. 2

  Request timed out.

If the ping does not pass, check the connection between the cable and the module, the IP address, and other WINOOWs settings.

[Articulation Policy Designation Screen]

• Ethernet module routing setup screen (QnA series only)

a) Network Number A network number assigned to the connected Ethernet network. This network number must match the number specified in the network parameters of the connected PLC and is the only number in MELSECNET/10 and Ethernet.

b) Station number (station number of the personal computer) A station number assigned to the computer of the WINOOWs system. For Mitsubishi PLCs and other computers in the network, this number is necessary to be the only.

c) IP Address Assign an IP address to the PLC.

d) Hostname Specify a hostname for the PLC. The hostname needs to be registered in the Hosts file. Note: It is necessary to specify either an IP address or a hostname for the policy PLC.

e) Station Number Specifies the station number assigned to the AJ71QE71.

f) MNET/10 Routing Information Parameter Modification System. Select an MNET/10 path method that is the same as the path method specified in the PLC network parameters.

g) Other Stations If you want to access another PLC through a AJ71QE71 Mitsubishi PLC, please specify the network number and station number of the other Yonghong PLC. If the network number is not a network directly connected to the PLC of the AJ71QE71, it is necessary to set the path parameters.
More on that
Advantages and disadvantages of Mitsubishi's different output types Advantages and disadvantages of Mitsubishi's different output types

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is adapted to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...

Mitsubishi FR-A700 series inverter problem Mitsubishi FR-A700 series inverter problem

1. Consultation question: FR-A700 series Mitsubishi inverter, the suffix is ending in -CA1, what kind of inverter? Solution: The suffix -CA1 is a special model with take-up control. 2. Consultation question: FR-A ...

Debugging method of servo motor - Mitsubishi Debugging method of servo motor - Mitsubishi

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by default; Save this state to ensure that this is the status when the control card is powered on again. ...

PLC Programming Recommendations – Mitsubishi PLC PLC Programming Recommendations – Mitsubishi PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many hours on the screen that require "manual", "active" and other control forms (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1 MOV will be changed to a ...

Review and comparison of Mitsubishi PLC control inverter methods Review and comparison of Mitsubishi PLC control inverter methods

1. The switching signal of PLC controls the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...

Precautions for the use of Mitsubishi servo motor with brake Precautions for the use of Mitsubishi servo motor with brake

1. Occasions with brake servo motors: The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...

Mitsubishi FX1N switching power supply fault repair Mitsubishi FX1N switching power supply fault repair

Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged). Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.

Mitsubishi touch screen GT10 series models and their features Mitsubishi touch screen GT10 series models and their features

GT1020 touch screen ● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches ●3-color LED backlight for added visibility ●High brightness liquid crystal, clear under light ● Resolution 160×64, standard memory 512K ●Inside ...

Mitsubishi PLC command negation, empty operation and END, etc Mitsubishi PLC command negation, empty operation and END, etc

Introduction to Mitsubishi PLC directives such as negation, air operation and END The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...

Mitsubishi servo about the selection of robot methods Mitsubishi servo about the selection of robot methods

When evaluating which process is suitable for which approach in the production environment, it is important to carefully consider the problem you want to deal with and consider all the costs that the robot can save: cutting waste, improving efficiency, improving yield, improving safety, or reducing labor costs. These costs ...

Mitsubishi Electric MPD series IGBT modules Mitsubishi Electric MPD series IGBT modules

Mitsubishi Electric's newly developed new MPD series IGBT modules will be unveiled at PCIM Asia 2012 (BoothNo). :301) June 19-21 at the Shanghai World Expo Complex. The new MPD series is very suitable for water-cooled design, and is a high-current power supply with good heat dissipation performance and strong reliability.

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

Anti-interference measures for PLCs and touch screens - Mitsubishi PLC Anti-interference measures for PLCs and touch screens - Mitsubishi PLC

1. Select the power supply with excellent performance and press the disturbance introduced by the power grid The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...

Methods for shortening the scanning cycle of PLC programs – Mitsubishi Methods for shortening the scanning cycle of PLC programs – Mitsubishi

1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers. 2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S; 3. Try to prevent the transformation of data types, ...

Software or hardware reasons for Mitsubishi PLC crash Software or hardware reasons for Mitsubishi PLC crash

1. Hardware (1) I/O channeling, the PLC automatically detects the I/O fault and enters the STOP mode. (2) The I/O is damaged, and the program runs to the response signal that needs the I/O, and cannot execute the instruction downward. (3) Expansion module (functional, such as A/D) ...

How to deal with Mitsubishi PLC failures - Mitsubishi How to deal with Mitsubishi PLC failures - Mitsubishi

01. Base system problem In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base. 2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

Analysis of PLC and inverter connection problems - Mitsubishi Analysis of PLC and inverter connection problems - Mitsubishi

When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1. PLC switch command signal input Inverter input ...

Classification of Mitsubishi touch screens Classification of Mitsubishi touch screens

At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors. 1. Resistive contact screen The screen body of the resistive contact screen ...

Mitsubishi Electric appeared at the 2021 China Smart Expo Mitsubishi Electric appeared at the 2021 China Smart Expo

From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top