The newly launched Lexium28S Sercos III bus servo with BCH2 servo motor is available as a pre-order product portfolio to meet the needs of motion control and optimize the function of the machine. Lexium28S servo drives, available in 4 sizes, 10 models, with power ranging from 0.05KW to 4.5KW. It can share the DC bus, save energy and improve power during operation; It has the STO safety torque enclosure function, which is an integral part of the machine safety system, helping to simplify the setup of equipment and facilities that require cluttered safety equipment, and improving the functionality during maintenance operations. Built-in 32 sets of motion control tasks, which can meet the most simple use needs of emerging economy markets. No power download, can quickly set parameters; The driver PCB board has a reinforced protective coating, which can block dust pollution and avoid short circuits; It has passed various international certifications (CE, UL, TUV, WEEE) and can be used for export. The BCH2 servo motor is available in three types: 20-bit singleturn absolute encoder, 20-bit multiturn absolute encoder and 23-bit optical encoder. All motor shaft ends are oil-sealed, and the protection level reaches IP65 to complete the best waterproof and dustproof effect. The power mask is 0.05kw to 4.5kw, the rated torque is from 0.16Nm to 28.6Nm, and the rated speed is from 1500rpm to 3000rpm. Different levels of motor inertia are available for a wide range of applications.
The combination of Lexium28S servo drive and BCH2 servo motor, combined with Schneider Electric Modicon M262 motion controller, provides you with a cost-effective solution for synchronous motion control. Under this solution, users can connect to cloud channels through cloud protocol encryption to complete data migration to the cloud. Thanks to the M262 synchronous operation, the program can synchronize up to 16 axes, 1 ms for 4 axes, 2 ms for 8 and 16 axes. In addition, a series of standard and advanced motion control functions such as zero-backing, synchronization of Sercos devices with motion tasks, editable CAM curves, transmission forms (master/slave utility blocks), encoder inputs and virtual axes can be synchronized with the motion program. With these advantages, the Modicon M262 manipulator and the Lexium28S servo solution plan can help users improve the functionality of their equipment, improve control accuracy, and improve production speed. In addition, unlike other communication protocols, the Sercos III communication protocol supports a ring topology next to the line topology, so that if the Ethernet cable fails, the Sercos III network can be switched to a line topology, so that the master device can continue to communicate with all slaves in the network. In the event of a communication failure, the system will not be interrupted, and the equipment will not be stopped.
Modicon M262 and Lexium28S solutions for packaging occupations, precise handling, quick response, and improved power; In the material processing profession, the Lexium28S not only captures signals quickly, but also accomplishes improved accuracy; In the printing industry, the product installation is compact, and the peripheral auxiliary equipment is reduced, and the cost is reduced. Schneider Electric's Motion Handling Solutions plan keeps pace with the times, inspires infinite possibilities, and becomes a solid help on your way to success.
|
More on that
|
Schneider Thermal Relay Model Meaning
The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay ...
|
|
Instrumentation mechanical equipment system - Schneider
1. Power system:
The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...
|
|
Schneider AC inverter usage category
Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...
|
|
Schneider Multi9 Series C120 FAQs
1. What are the characteristic curves of Schneider Multi9 series C120L?
A: C/D curve.
2. What is the rated current level of Schneider Multi9 series C120?
A: 63A, 80A, 100A, 125A.
3. Shi ...
|
|
Schneider appeared at the 5th China Power Distribution Technology Summit Forum
Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...
|
|
The control mode of low-voltage inverter - Schneider
From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods:
1. Sinusoidal pulse width modulation
Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...
|
|
Advantages of Schneider molded case circuit breaker
The contact orientation is 100% secure
As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...
|
|
Schneider EZD series molded case circuit breaker is recommended
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.
|
|
Schneider diode selection experience and substitution method
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...
|
|
Precautions for false load connection in Schneider inverter debugging
There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...
|
|
Fault check steps for frequency converters - Schneider frequency converters
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Schneider ATV32 inverter malfunction
1. The ATV32 inverter reports that the bLF is a brake control fault.
Possible causes: 1. The brake release current is not reached. 2. When the braking logic control is assigned, only the closing frequency threshold [brake closure frequency] (bEn) is adjusted.
Repair measures: 1. Check the inverter/electric ...
|
|
Schneider molded case circuit breakers NSX, CVS, EZD differences
1. NSX series is Schneider's high-end molded case circuit breaker, with the best performance in all aspects, and of course, the price is also the most expensive.
2. CVS series, which is the main series of Schneider, has the second best performance compared with the NSX series, but can meet the vast majority of applications, and the price is more affordable.
3 ...
|
|
Schneider touch screen touch deviation causes
(1) Problem--: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when calibrating the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: Some districts ...
|
|
Advantages of the Schneider Magelis GXU touchscreen
1. Save capital contribution
Focus on central function (true color LCD, serial communication interface, USB connection, Ethernet interface, etc.)
2. Save space
Compact structure planning, only 38mm thick
The fuselage is reserved for communication wiring ...
|
|
Switching power supply circuit fault phenomenon - Schneider
1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows:
1 ...
|
|
Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award
Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.
|
|
How Schneider contactors work
How it works
Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect with the equipment of the high-current control circuit, it has been used in electrical engineering.
|
|
Inverter power settings, waveform test issues
1. After the inverter is repaired, the power number demand is corrected, don't forget
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Schneider UPS power supply installation precautions
The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device.
Generally speaking, UPS power supply ...
|
|