The circuit breaker is a fundamental low-voltage electrical appliance, which has the function of overload, short circuit and undervoltage maintenance, and has the ability to maintain the line and power supply. Circuit breaker is an indispensable product in electrical safety. Due to different applications, there are molded case circuit breakers, frame circuit breakers, miniature circuit breakers and other classifications. There are many brands of circuit breakers available in the market, and the prices vary. The following points are to learn about LS Power's ABE series molded case circuit breaker.
ABE series molded case circuit breaker features:
Non-adjustable thermomagnetic tripper
It has a robust engineering plastic housing
A variety of accessories are available, such as post-board wiring and swivel handles
The three-stage residual current circuit breaker is the same size as the distribution circuit breaker
The scale is compact, economical and practical, and the segmentation can be greatly improved compared with the previous one.
ABE series selection based on:
Take ABE203b as an example, this product is 3 poles, and the product has 5 currents to choose 125A; 150A; 175A; 200A; 225A. The type of tripper is thermomagnetic type, and there are two wiring methods in front of the board and behind the board; Bolt national installation; Optional accessories include auxiliary contacts, alarm contacts, and shunt trippers; undervoltage trippers; Manually rotate the handle; terminal covers; Wiring behind the board; Insulating partitions.
|
More on that
|
Inverter maintenance principle analysis and inspection method
Principle analysis is the most fundamental way to eliminate the problem, when other methods are difficult to see the effect, you can start from the basic principle of the circuit, step by step to view, and finally find out the cause of the problem. To use this method, it is necessary to have a clear understanding of the principle of the circuit, and to grasp the various ...
|
|
Wiring of the main circuit of the inverter - LS generates electricity
1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, it is necessary to clean the trivial wires, which may cause abnormalities, failures and problems, and it is necessary to always keep ...
|
|
The difference between voltage type and current type inverter - LS generates electricity
The differences between voltage type and current type inverter are mainly manifested in:
(1) the load of the buffer inverter of reactive power is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Because power electronic switches ...
|
|
The production power takes you to read the PLC ladder diagram
1. Trapezoidal stairs start from the horizontal line and end up with a vertical line (generally you can omit not to draw, only draw the left busbar). On the left side of each row is the junction combination, indicating the conditions that drive the logic coil, while the logic coil indicating the effect can only be connected to the bus on the right. The contact can not appear in the coil right ...
|
|
Parameter setting of LS power inverter
The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. All kinds of inverters ...
|
|
An internal component of LS's power circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Introduction of plc inverter - LS power generation
Because the imported products of the inverter brand have their own PLC function, they mainly play an important role in the control effect of mechanical equipment, and play an important role in the equipment, which can regulate the operation and control of the machine and meet the requirements of users.
It should be scale
pLC ...
|
|
How to choose LS contactors
The working form of LS contactor:
Generally speaking, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and make their AC contactor ...
|
|
The main structure of LS power AC contactor
The operating principle of the contactor is: when the contactor coil is energized, the coil current will generate a magnetic field, and the generated magnetic field will make the static iron core attract the moving core with electromagnetic attraction, and drive the communication contactor point action, the normally closed contact is disconnected, and the normally open contact is closed, and the two are linked. When the coil is de-energized ...
|
|
Selection principles and key points of AC contactors for power production
1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage.
2. The operating frequency of the motor is not high, such as compressor, water pump, air ...
|
|
Introduction to LS Master-K series PLC programming
LS is an electrical equipment company affiliated to LG, kglwin3.62 programming software Chinese version is a professional plc programming software designed to help daily more efficient planning and development software, the software supports the programming and debugging of LG Master-K series and LG MASTER-K series, and provides ...
|
|
Introduction of LS PLC programming software
LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.
|
|
LS inverter frequency conversion mode
1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...
|
|
Asynchronous motor with inverter - LS generates electricity
Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads:
1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...
|
|
LS Group witnesses the reopening of the "Viet Nam Professional Football League".
The Viet Nam Professional Football League, sponsored by LS Group, began operations in June and is hosted by Viet Nam Professional Football Joint Stock Company. With the comeback of football events such as the Korea K League and the Bundesliga, more and more football events are also brewing to restart.
...
|
|
Selection of the color of the conductor of the high and low voltage switchgear - LS power production
1 AC three-phase circuit
a) Yellow for phase A, green for phase B, and red for phase C;
b) Light and blue colors for the neutral line or neutral line;
C) Yellow and green two-color wires are used for safety grounding wires.
2 AC circuits connected by twinax wires or stranded wires: red, black ...
|
|
The power of LS power inverter is selected
The relationship curve between the load rate β and the power η of the inverter can be seen: when β = 50%, η = 94%; When β = 100%, η = 96%. Although the β has doubled, the η change is only 2%, but it is also considerable for medium to high power (a few hundred kilowatts to several thousand kilowatts) electric motors. The system power is equal to the inverter power ...
|
|
The difference between overload and overcurrent of the inverter
(1) The maintenance objectives are different
Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded.
...
|
|
Analysis of the fault problem of LS power terminal block
From the point of view of application, the function of the terminal block should be achieved: it is necessary to conduct the local conduction of the touch part, and the touch is reliable. The insulating part should not be conducted, and it is necessary to insulate it firmly. There are three common forms of fatal problems in terminal blocks:
...
|
|
LS power generation installs the switching power supply step
The basic method of switching the power supply of the device requires us to carry out the corresponding installation and debugging according to the specific model and the device environment. And in the process of installation, we need to pay more attention to safety and stability to ensure the normal operation of the switching power supply.
...
|
|