Mitsubishi inverter fault detection method

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. The output side of the inverter is short-circuited, such as the connection line between the output end and the motor, or the short circuit inside the motor, etc.;

2. The inverter itself is not working normally, such as the two inverter equipment of the same bridge arm in the inverter bridge are constantly alternating in the working process. For example, due to the high ambient temperature or the aging of the inverter equipment itself, the parameters of the inverter equipment change, resulting in the alternation process, one equipment has been turned on, while the other equipment has not yet had time to shut down, resulting in the "straight through" of the upper and lower two devices of the same bridge arm, so that the positive and negative poles of the DC voltage are in a short circuit condition. 2. When the inertia of the load is large, and the time of the increase is set too short, it means that in the process of speed-up, the working efficiency of the inverter rises too fast, and the synchronous speed of the motor rises quickly, and the speed of the rotor of the motor cannot keep up because of the load inertia, and the result is that the speed of the speed-up current is too large. 3. Overcurrent in the speed reduction.

                            Mitsubishi inverter fault detection method

3. The current faulty circuit board is generally tightly structured, the degree of integration is very high, the signal flow is scattered and complex, and any equipment damage may form a fatal problem. Because the equipment is highly integrated, the maintenance personnel are required to pay more attention to the common sense of equipment and equipment test compared with the common sense of circuits.

4. There are many strange problems in the circuit board, such as: deterioration of integrated IC characteristics, functional failure, false soldering of pins, short circuit, broken circuit board connection, electromagnetic signal disturbance, environmental dust influence and program loss, etc., can lead to problems, so all kinds of situations need to be considered. Because the problem is complex, it is not only necessary to analyze and test the equipment, but also require the repair personnel to enhance the comprehensive judgment ability of the problem. To sum up, today's excellent circuit repairers are by no means the so-called craftsmen who "are unwilling to do it, and Lai Han can't do it" in the past, but compound repair experts who have high requirements for all aspects of their essence.

Anything that seems complex has a regularity to its connotation, and the same is true for circuit board faults. For example, when you encounter a fuse burning problem, you will naturally think that there may be a short circuit in the power supply. Because a large current is required to blow a fuse, the power supply circuit is closely connected to the fuse, which is first of all questionable. The phenomenon of the problem and the cause of the formation have a connotative connection in this way, and it has its own regularity.

More on that
Mitsubishi inverter setting parameter adjustment method Mitsubishi inverter setting parameter adjustment method

Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation. ...

The interaction between the PLC and the touch screen is consistent - Mitsubishi The interaction between the PLC and the touch screen is consistent - Mitsubishi

When the contact screen is connected with the PLC, in fact, the memory of the PLC is used, (the contact screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the contact screen and the PLC communication is generally a master/slave relationship, that is, the contact screen reads data from the PLC, and after making a judgment, it is displayed in the display ...

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

Mitsubishi Electric CNC numerical control system grounding specification Mitsubishi Electric CNC numerical control system grounding specification

What is the effect of machine tool grounding? 1. Insist that the machine shell and the ground insist on the same voltage. 2. In the event of abnormal external voltage or leakage, the maintenance personnel and the machine tool will not be damaged electrically. 3. Avoid damage to CNC equipment caused by external voltages such as surges. 4. ...

Mitsubishi PLC command negation, empty operation and END, etc Mitsubishi PLC command negation, empty operation and END, etc

Introduction to Mitsubishi PLC directives such as negation, air operation and END The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...

Mitsubishi FX series PLC master control command Mitsubishi FX series PLC master control command

The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs. Master Control Command (MC/MCR) (1) MC (Master Control Command) for common tandem contacts ...

PLC control system daily maintenance process - Mitsubishi PLC control system daily maintenance process - Mitsubishi

After overhauling and confirming that all connections of the system are accurate, power on the relevant modules until the card indicator is normal. The initiation process of the system after the scheduled repair is as follows: (1) Power supply. Open power supply equipment (including throwing up...

The difference between Mitsubishi PLC source type and leak type The difference between Mitsubishi PLC source type and leak type

Mitsubishi PLC split source type (PNP) or drain type (NPN), here are their differences 1: Leakage logic: When the current flows out of the signal input terminal, the signal becomes ON, which is leakage logic. The current flows through the terminals and has the output characteristics of an NPN transistor. 2: Source logic: When ...

Mitsubishi servo motor realizes positioning function Mitsubishi servo motor realizes positioning function

The motion control command of the PLC realizes the perfect positioning function. Briefly describe the Mitsubishi PLC positioning instructions, which can be divided into origin regression instructions DSZR, ZRN, positioning instructions PLSY, PLSR, DRVI, DRVA, variable speed operation PLSV.3 In the meantime, PLSY and PLSR are pulse output instructions, and their positioning functions are relatively ...

The inverter completes the multi-speed function - Mitsubishi The inverter completes the multi-speed function - Mitsubishi

The inverter can be preset with a number of different speed points, and then complete the scheduling of multiple speed stages. The specific completion method is as follows: You can set a number of different speed points in the VFD, and you can generally set the maximum speed, minimum speed, and several center speed points. According to the needs, choose ...

The choice of industrial tablet case – Mitsubishi The choice of industrial tablet case – Mitsubishi

Tablet PC can often be seen in today's daily life, it can be brought stronger, but also more popular with us, industrial tablet PC is gradually widespread, because industrial use will cause Tablet PC is very simple damage, so generally will use maintenance covers, so ...

Mitsubishi PLC login password setting operation Mitsubishi PLC login password setting operation

Method 1 1. Hit the PLC from RUN to STOP Mitsubishi's PLC has a special method of setting landing keywords, and it is necessary to ensure that the PLC is in a state of shutdown in order to successfully write the landing keywords. In the run running condition, the performance of the write will appear "Unable to ...

Mitsubishi PLCFX3U positioning control Mitsubishi PLCFX3U positioning control

Origin regression command with DOG lookup function Mitsubishi PLCFX3U origin regression command with DOG lookup function: DSZR. 1. The workbench runs in the direction of the value reduction of the current value register (generally runs in the opposite direction M8342 ...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

Confirmation and clearing of Mitsubishi inverter alarm history Confirmation and clearing of Mitsubishi inverter alarm history

When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...

Pay attention to the problem when choosing an inverter - Mitsubishi Electric Pay attention to the problem when choosing an inverter - Mitsubishi Electric

The current value of the motor is used as the basis for the selection of the inverter, and the rated power of the motor is only for reference. Compared with the general squirrel cage motor, the winding motor simply has the problem of overcurrent tripping, and the slightly larger capacity than the usual ...

Pay attention to the wiring of the Mitsubishi PLCI/O terminal Pay attention to the wiring of the Mitsubishi PLCI/O terminal

1. Enter the wiring (1) The input wiring should generally not exceed 30 meters. However, if the environmental disturbance is small and the voltage drop is not large, the input wiring can be appropriately longer. (2) The input/output lines cannot be separated by the same cable, and the input/output lines should be separated. (3) As far as possible, choose normally open ...

The wiring steps of the input and output circuits of the Mitsubishi PLC The wiring steps of the input and output circuits of the Mitsubishi PLC

The wiring diagram steps of the input and output circuit of Mitsubishi PLC, there are generally three types in the wiring diagram of the input and output of the PLC, one is DC 12-24V input, and there is output, so what about the external input? (1 ...

Mitsubishi PLC Step Instruction Instructions for use Mitsubishi PLC Step Instruction Instructions for use

1. Step Instruction (STL/RET) Step instruction is an instruction that is specially planned for sequential control. In the field of industrial control, many control processes can be completed by sequential control, and the use of step instructions to complete sequential control is not only convenient to complete, but also easy to read and modify. There are two in the FX2N ...

Mitsubishi PLC controls the control method of the inverter Mitsubishi PLC controls the control method of the inverter

1. Use the switching signal of PLC to control the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and SG input ports of the inverter. The PLC can control the inverter through the program.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top