When the contact screen is connected with the PLC, in fact, the memory of the PLC is used, (the contact screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the contact screen and the PLC communication is generally a master/slave relationship, that is, the contact screen reads the data from the PLC, and the judgment is displayed after the judgment, the contact screen and the PLC communication is generally not a separate communication module, and the PLC generally reads and integrates the port of communication with the contact screen, but this depends on the type of contact screen and PLC, Specifically, after the contact screen and PLC type are selected, it can be solved by checking the echo materials

                            The interaction between the PLC and the touch screen is consistent - Mitsubishi

Communication between the touch screen and the PLC is not difficult. The main result of the connection between the contact screen and the PLC is that the hardware such as buttons and indicator lights are omitted. The PLC does not require any separate functional modules. You only need to make an internal button (middle bit M) on the PLC control program, and the contact button configured on the contact screen corresponds to the middle bit.

Connection method between PLC and contact screen:

Way:

The GP37W2 of Proface is connected to the programming port of the PLC

The PLC has added an FX1N-422BD module to connect the modules

Eview's MT4300L touch screen (both ports COM0COM1 are capable)

More on that
Mitsubishi PLC's six programming languages Mitsubishi PLC's six programming languages

(1) Ladder diagram Programming language is traditionally called a ladder diagram. The ladder diagram follows the method of relay control circuit, and it can also be said that the ladder programming language is simplified from the symbol evolution on the basis of the logic control of relays and contactors commonly used in electrical control systems.

Mitsubishi AnS series analog module bias and gain applications Mitsubishi AnS series analog module bias and gain applications

In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...

Self-locking function of servo motor - Mitsubishi Self-locking function of servo motor - Mitsubishi

Press the abort button SB1, the contactor KM coil is de-energized, and the auxiliary normally open contact of the KM connected in parallel with SB2 is disconnected to ensure that the KM coil continues to lose power after the button SB1 is released, and the main contact of the KM connected in series in the motor circuit is continuously disconnected and the motor stops. Auxiliary to the KM in parallel with SB2 ...

Find PLC fault method – Mitsubishi PLC Find PLC fault method – Mitsubishi PLC

PLC is an industrial small computer, it has a problem, the first thing to clean up is the PLC ontology problem is still a peripheral problem, if there is a problem with the PLC ontology, often the ERR light is on, maybe the red light is flashing, the normal situation is generally RUN running green light, if it is the ontology to produce this kind of problem, ...

Which components in the Mitsubishi inverter need to be replaced regularly Which components in the Mitsubishi inverter need to be replaced regularly

Mitsubishi inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, in a certain period of time will deteriorate, thus reducing the characteristics of the inverter, is ...

Mitsubishi Electric appeared at the 2021 China Smart Expo Mitsubishi Electric appeared at the 2021 China Smart Expo

From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...

Mitsubishi PLC ladder programming method Mitsubishi PLC ladder programming method

Ladder concept: It is a ladder pattern composed of graphical symbols that indicate the programming elements inside the PLC. Rules for writing ladders: Suitable for the left bus, finally the right bus The contacts should be drawn on the horizontal line, not ...

Analysis of PLC and inverter connection problems - Mitsubishi Analysis of PLC and inverter connection problems - Mitsubishi

When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1. PLC switch command signal input Inverter input ...

Mitsubishi PLC control system electroplating production line design Mitsubishi PLC control system electroplating production line design

Planning PLC control system control requirements for electroplating production line: 1) SQ1-SQ4 is the driving advance and retreat limit switch, and SQ5-SQ6 is the upper and lower limit switches. 2) The workpiece is lifted to SQ5 to stop, and the car is driven to SQ1 to stop.

The difference between a Mitsubishi servo motor and a stepper motor The difference between a Mitsubishi servo motor and a stepper motor

First, the control accuracy is different The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors that have a smaller step angle after being subdivided. Communicate the control of servo motor ...

Methods for shortening the scanning cycle of PLC programs – Mitsubishi Methods for shortening the scanning cycle of PLC programs – Mitsubishi

1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers. 2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S; 3. Try to prevent the transformation of data types, ...

Characteristics of servos and advantages of Mitsubishi servos Characteristics of servos and advantages of Mitsubishi servos

The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.

Mitsubishi servo motor types and advantages Mitsubishi servo motor types and advantages

1. DC servo The structure is simple and easy to operate. However, considering the actual operation, the DC servo motor has introduced mechanical equipment for reversing installation, which increases the cost, has many problems, and is inconvenient to maintain, and often interferes with the production and manufacturing due to the sparks of carbon brushes, and electromagnetic interference will occur. Combine...

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

Mitsubishi servo about the selection of robot methods Mitsubishi servo about the selection of robot methods

When evaluating which process is suitable for which approach in the production environment, it is important to carefully consider the problem you want to deal with and consider all the costs that the robot can save: cutting waste, improving efficiency, improving yield, improving safety, or reducing labor costs. These costs ...

Mitsubishi inverter FR-A800 series selection Mitsubishi inverter FR-A800 series selection

Q: When will the CS84 series inverter be selected? A: CS80 series inverter belongs to the diversified function of small intelligent inverter, covering excitation control and general flux vector control, the volume is 57% of the same model, very fast, in some general functions can be used in this model ...

Introduction of Mitsubishi PLC series Introduction of Mitsubishi PLC series

1. Main substrate There are a variety of models such as Q32SB, Q33SB, Q35SB, Q33B, Q35B, Q38B, Q312B and other main substrates for Q series PLC, and the meaning of the model is as follows: In the meantime, the "S" stands for ultra-thin main substrate, and only Q61SP power modules can be used, and they cannot be ...

The Mitsubishi PLC FX2N is connected to a computer through the group Taiwang The Mitsubishi PLC FX2N is connected to a computer through the group Taiwang

In the PLC control system, the content that needs to be displayed mainly includes timer value, counter value and data register value, and the data display method can be summarized into two fundamental types: one is based on the PLC data communication interface, such as RS-232, RS-485/422, and the display device also has such an interface.

Inverter overload fault factor - Mitsubishi inverter Inverter overload fault factor - Mitsubishi inverter

1) The mechanical load is too heavy The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383