1. The inverter must be selected correctly.
2. Read the product manual carefully, and wiring, installation and use in accordance with the requirements of the manual.
3. The inverter device should be reliably grounded, and the radio frequency interference should be suppressed to prevent the inverter from causing electric shock due to leakage.
4. When the speed of the motor is controlled by the inverter, the temperature rise and noise of the motor will be higher than that of the grid power (power frequency); When running at low speed, due to the low speed of the motor blades, attention should be paid to ventilation and cooling and appropriate load reduction, so as to avoid the temperature rise of the motor exceeding the allowable value.
5. The impedance of the power supply line should not be too small. When the capacity of the distribution transformer is greater than 500KVA or the capacity of the distribution transformer is greater than 10 times the capacity of the inverter, or when the inverter is connected to the distribution transformer very closely, due to the small impedance of the circuit, a large surge will be generated on the inverter instantly, which will damage the rectifier elements of the inverter. When the line impedance is too small, an AC reactor should be installed between the grid and the inverter.
6. When the three-phase voltage unbalance rate of the power grid is greater than 3%, the peak value of the input current of the inverter is very large, which will cause the inverter and the connection to overheat or damage the electronic components, and the AC reactor needs to be installed. In particular, when the transformer is V-shaped, it is more serious, in addition to installing a reactor on the AC side, it is also necessary to install a DC reactor on the DC side.
7. Do not install too large capacitors on the incoming side because of the increase of power factor, nor can you install capacitors between the motor and the inverter, otherwise the impedance of the line will decrease, produce overcurrent and damage the inverter
8. The outlet side of the inverter can not be connected in parallel to compensate for the capacitor, nor can the capacitor be paralleled in order to reduce the high-order harmonics of the output voltage of the inverter, otherwise the inverter may be damaged, in order to reduce the harmonics. Reactors can be connected in series.
9. The start and stop of the motor with the speed regulation of the inverter cannot be directly operated by the circuit breaker and contactor, but the control terminal of the inverter should be used to operate, otherwise the inverter will be out of control and may cause serious consequences
10. It is generally not advisable to install an AC contactor between the inverter and the motor, so as to avoid overvoltage and damage to the inverter between the interrupts. If additional installation is required, the output contactor should be closed before the inverter is operational.
|
More on that
|
Analysis of the fault code of Megmeet welder
1. E1: indicates sensor failure. In this case, it is necessary to check whether the sensors of Megmeet are damaged or whether the wiring is loose.
2. E2: Indicates overweight load. At this point, it is necessary to check whether the load of Megmeet exceeds the set maximum load.
3. E3: Indicates battery ...
|
|
What are the characteristics of Megmeet PLC - PLC working process?
(1) The PLC adopts the working mode of centralized sampling and centralized output, which reduces the influence of external interference.
(2) The working process of PLC is the process of cyclic scanning, and the length of cyclic scanning time depends on the speed of instruction execution, the length of the user program and other factors.
(3) Output ...
|
|
Megmeet PLC common faults
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
Megmeet PLC - common causes and treatment methods of PLC failures
Peripheral circuit component failure
This type of failure often occurs in the failure of the PLC after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working.
The input circuit is PLC to accept switching quantities, analog quantities, etc.
|
|
Megmeet inverter - classification and introduction of high-voltage inverter
There are many types of high-voltage inverters, and their classification methods are also diverse. According to whether there is a DC part in the intermediate link, it can be divided into AC inverter and AC AC inverter; According to the nature of the DC part, it can be divided into current type and voltage type inverter; According to whether there is an intermediate low-voltage circuit, it can be divided into high...
|
|
Megmeet PLC - Introduction to the basic structure of PLC controller
1. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...
|
|
Megmeet inverter - a common measure for anti-interference of high-voltage inverters
(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference.
(2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...
|
|
Megmeet inverter - the selection principle and precautions of the inverter
1. Select the inverter according to the load characteristics
A: Fans and pumps are the most common loads: the requirements for the inverter are the simplest, as long as the inverter capacity is equal to the capacity of the motor (air compressors, deep water pumps, sediment pumps, and fast-changing music fountains need to increase their capacity).
...
|
|
Megmeet drives – what are the components of a drive?
The inverter is composed of a main circuit, a rectifier, a flat wave circuit, and an inverter.
1) Main circuit:
The main circuit is the power conversion part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the DC ...
|
|
The principle and characteristics of Megmeet tungsten argon arc welding and resistance welding
3) Tungsten argon arc welding (TIG)
Non-melting electrode gas arc welding, TIG welding, English is Tungsten Inert Gas (abbreviated TIG), also known as Gas Tungsten Arc Welding (abbreviated GTAW)
The principle is: TIG welding is in argon and other inert gases.
|
|
Megmeet PLC – the three programming languages of PLC
1. The ladder diagram language is the most commonly used programming language in PLC programming. The CPU reads physical input into a memory table, often referred to as an "input table". The form is evaluated for use in the procedure. Different platforms, using different types of registers; In each scan cycle, follow from left to right, ...
|
|
Megmeet inverter - precautions for inverters at high temperatures
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately;
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C;
3. Summer ...
|
|
Megmeet inverter - the basic method and steps of inverter commissioning
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display of the inverter window is normal, if it is incorrect, it should be reset, otherwise it should be ...
|
|
Megmeet inverter - introduction to the classification of inverters
1. Classified according to the input voltage level
According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.
|
|
Megmeet welding machine - failure and maintenance method of DC welding machine
1. Fault phenomenon: light voltage abnormal indicator
Cause: Due to the slow start-up action, the switch contact is not synchronized.
Solution: You can turn the device off and on again.
2. Fault phenomenon: the fan does not rotate, and the abnormal voltage indicator light is lit together
Causes ...
|
|
Megmeet welding machine - Classification and difference of laser spot welding machine
Laser spot welding machine, also known as resistance welding machine, is usually divided into three categories according to the nature of the welding power source: 1. AC spot welding machine; 2. Energy storage spot welding machine; 3. DC spot welding machine.
1. AC spot welding machine
Precision AC spot welding machine generally refers to the spot welding machine with a power of less than 16KVA.
|
|
Megmeet welding machine - an introduction to the advantages and disadvantages of resistance welding
Advantages of resistance welding:
1。 When a nugget is formed, it is always surrounded by a ring of plastic, the molten metal is isolated from the air, and the metallurgical process is simple
2。 The heating time is short, the heat is concentrated, the heat affected zone is small, and the deformation and stress are small. In general, there is no need to arrange calibration and heat after welding.
|
|
Megmeet PLC - What are the features of the PLC program?
1. Correctness (low debugging cost)
First of all, the PLC program must be able to work correctly to meet the requirements of the actual control process. This is the essence of the PLC program, and if you don't do that, nothing else makes sense.
2. Reliability (low maintenance cost)
Not only to ...
|
|
Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use
Zhuzhou Lihui Technology Co., Ltd., a subsidiary of Megmit, has put into use a new production line of PEU intelligent production of new energy cars, leading the wave of intelligent production of PEU in the key "three electric" components of domestic new energy cars.
Zhuzhou Lihui Technology Co., Ltd. production workshop, a new ...
|
|
Megmeet inverter - the speed regulation method of high-voltage inverter
1. Hydraulic coupling method. That is, a hydraulic coupling device is inserted between the motor and the load in series, and the size of the coupling force between the motor and the load is adjusted by the height of the liquid level, so as to realize the speed adjustment of the load;
2. Cascade speed regulation. Tandem speed regulation must use a wound asynchronous motor, and the rotor ...
|
|