Key features of the RLC thermostat:

Create Date: 2024-8-30 12:03:23|Source: RKC

Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;

The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;

Fuzzy theory combined with traditional PD methods, control fast and stable, advanced tuning scheme,

Outputs selectable: cut-off contacts, logic levels, thyristor single-phase or three-phase zero-crossing or phase-shifting trigger anti-flush or transshipment pulses, analog. Two definable alarm point outputs are also included.

Key features of the RLC thermostat:

More on that
Where you need to pay attention to the wiring of the RRKC thermostat Where you need to pay attention to the wiring of the RRKC thermostat

1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. 4. Instrument power cord ...

What should be paid attention to when installing RRKC thermostats - pop-up thermostats What should be paid attention to when installing RRKC thermostats - pop-up thermostats

1. The use environment of the sudden jump thermostat should avoid stains and moisture, otherwise it will affect the electrical performance of the product, and the thermostat must be used in a working environment with a relative humidity of ≤ 90% and no contact with corrosive and flammable mediums. For use in wet environments or submerged liquids, the thermostat ...

RLC thermostat - introduction to the performance characteristics of intelligent digital display controller RLC thermostat - introduction to the performance characteristics of intelligent digital display controller

1. The special integrated instrument chip has more reliable anti-interference and stability. 2. Signal input, which can be matched with commonly used thermal signals through menu settings. 3. The display range, transmission output range, alarm value and alarm mode can be modified online. 4. Soft ...

Overview of the RLC thermostat Overview of the RLC thermostat

CH and CD series intelligent temperature controller is a multi-functional adjustment instrument with special microprocessing, which adopts switching power supply and surface mount technology (SMT), so the instrument is delicate and compact, and the performance is reliable. The unique self-diagnosis function, self-tuning function and intelligent control function make it possible for the operator to pass the ...

RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement

1. Select the appropriate level gauge First of all, it is necessary to choose the appropriate level gauge. The following factors should be taken into account in the selection of a level gauge: Measure the properties of the medium: e.g., temperature, pressure, viscosity, corrosiveness, etc. Measuring range: i.e. the height range of the liquid ...

RKC Thermostat – Teach you how to choose a thermostat RKC Thermostat – Teach you how to choose a thermostat

(1) Size selection When replacing the thermostat, choose according to the original size; The newly added thermostat should take into account the overall coordination of the cabinet installed, too large to fit, too small to see the display, the same function of the thermostat, the price of large volume will be more expensive, small size may function expansion...

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

RLC Thermostat – The reason why the temperature control meter shows HHH RLC Thermostat – The reason why the temperature control meter shows HHH

The reasons why the temperature control table shows HHH are as follows: 1. The thermocouple signal line is reversed, or short. 2. If the temperature control meter is in normal use before, it is recommended to check whether the signal line of the thermocouple is broken. 3. The wire inside the thermocouple is broken. 4 ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

RRKC thermostat - common faults and solutions of stand-alone thermostats RRKC thermostat - common faults and solutions of stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

RKC thermostat - how to prevent freezing and heat preservation of instruments in winter? RKC thermostat - how to prevent freezing and heat preservation of instruments in winter?

In winter, the surface of the power plant's measuring instruments is frozen and condensed, which can lead to poisoning, fire and even explosion. Therefore, the cold and freeze protection of the appearance of the instrument is particularly important. First, the selection method (1) Choose the appearance with insulation device. According to the category of appearance ...

RK Thermostat - The working principle and device precautions of liquid expansion thermostat RK Thermostat - The working principle and device precautions of liquid expansion thermostat

How liquid expansion thermostats work Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...

What should I pay attention to when setting up my RKC thermostat? What should I pay attention to when setting up my RKC thermostat?

Wiring Warning: If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents: In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks. Power supply ...

RKC Level Gauge – Four mounting methods for buoy level gauges RKC Level Gauge – Four mounting methods for buoy level gauges

1. The buoy level gauge is welded and installed under the guide wire At the bottom of the container, determine the position according to the requirements of the movement direction of the level gauge buoy, and weld or rivet the support under the fixed guide wire. 2. Buoy level gauge ruler installation 1. The connecting part of the ruler should be flat.

Difference Between Thermocouple and RTD Difference Between Thermocouple and RTD

In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different. This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.

RRC thermostat - how to adjust the smart thermostat RRC thermostat - how to adjust the smart thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...

Introduction to the types of alarms for RKC thermostats Introduction to the types of alarms for RKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

RKC Level Gauge – Key points for using a float level gauge RKC Level Gauge – Key points for using a float level gauge

1. The level gauge is adjusted normally, and it is found that the float is "absorbed" for a period of time in a certain position after it is put into use. This is mainly caused by the level gauge passing through the steel platform device and being spaced too close to the steel plate. Therefore, it is necessary to pay special attention to the level gauge to connect the pipe wall with the steel platform device.

RKC Thermostat - How to Choose a Hot Spot Couple? RKC Thermostat - How to Choose a Hot Spot Couple?

The selection of thermocouples should be based on comprehensive considerations such as the scale of the operating temperature, the required accuracy, the atmosphere of the application, the performance of the measurement target, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement scale 1) The operating temperature is 1300-1800 °C, and the accuracy is required to be more accurate than ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top