The relationship between torque and performance of Mitsubishi servo motors

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. Additional torque

The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor.

2. Starting torque

The torque generated by the motor at the moment when a voltage is applied to the motor in the aborted condition is called the starting torque. The starting torque characterizes the starting ability of the motor, which is related to the starting method (such as step-down starting, communication servo motor frequency conversion speed regulation starting, winding motor series resistance starting, etc.).

For the directly started squirrel cage motor, the starting torque is generally 0.8-2.2 times of the additional torque. In general, the starting torque should be more than 1.25 times the additional torque, and the corresponding starting current should be 5-6 times the additional current.

Regarding the large DC servo motor, the starting torque is particularly large, so the starting current is also very large, so the large Guangzhou DC servo motor should not be started directly, and the voltage should be reduced. The exception is small Shenzhen DC servo motors and permanent magnet servo motors.

                               The relationship between torque and performance of Mitsubishi servo motors

3. Large torque

*High torque is the point where the torque stabilization zone of the motor is bordered by the unstable zone. If the load torque is greater than the maximum torque, the output torque of the motor will become smaller and enter the stalled rotor condition. At this moment, the current will be very high, and the motor will be burned out as a result.

4. Stalled torque

After the Japan servo motor enters the stalled rotation condition, the speed is zero, and the torque that the motor can output is the stalled torque.

5. The relationship between torque under different conditions

* The large torque is greater than the extra torque, but the stalled torque of the asynchronous motor may be greater than the * large torque or less than the additional torque, the former is due to the different motor parameters of the stalled rotor condition and the * large torque condition, and the latter is planned and confirmed according to the actual working conditions.

After the above introduction, when we use the motor, we should reasonably adjust the motor torque according to the operation status at that time.

Shenzhen Servo Huakexing is the general agent of Fuji servo motor, which can provide Fuji servo motor, Japan servo drive, Fuji servo motor price consultation, Fuji servo motor selection and Japan Fuji servo models stock supply.

More on that
Mitsubishi PLCFX2NCPU plate fault solution Mitsubishi PLCFX2NCPU plate fault solution

Customer's description of the problem: Mitsubishi FX2N-32MR-001, the PLC running light does not light up after powering on, and the alarm light is always on (hardware problem) Inspection and repair: turn on the power supply, power on the PLC, according to the detection process, the PLC is in the POWER...

Mitsubishi MELSEC iQ-F makes IoT a simple one Mitsubishi MELSEC iQ-F makes IoT a simple one

The MELSEC iQ-F series of small PLCs completes the high-speed system bus, supports a variety of networks, enriches the built-in functions, and makes it more convenient to use. From stand-alone use to network-based system proposals, we strongly support the needs of customers for "cutting-edge products in the manufacturing industry". Using the MELSEC iQ-F...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Introduction to the names and effects of capacitors in different circuits Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...

Mitsubishi PLC selection 5 elements Mitsubishi PLC selection 5 elements

Mitsubishi PLC selection - element 1: IO points The number of ZUI IOs that can be accessed by the Mitsubishi PLC control system. Mitsubishi PLC FX series now commonly used basic unit host is: FX1SFX1N, FX1NC, FX2N, FX2NC, FX3U. FX3UCFX3G, FX5U, 9 series. ...

Special function module of the Mitsubishi PLC FX series Special function module of the Mitsubishi PLC FX series

The communication module of PLC is used to complete the communication with other PLCs, other intelligent control equipment or computers. The following is a brief introduction to the FX series communication function shields, adapters and communication modules. (1) Communication expansion ...

Precautions related to transportation control of lithium batteries - Mitsubishi Precautions related to transportation control of lithium batteries - Mitsubishi

This Skills Brief introduces the United Nations requirements for lithium battery shipment controls and United States guidelines for lithium battery shipment controls. In addition, the content shown in this skill newsletter will be discontinued as of March 2020. ...

Introduction to Mitsubishi PLC Modbus communication and address allocation Introduction to Mitsubishi PLC Modbus communication and address allocation

When using Modbus communication in Mitsubishi PLCs, it is necessary to understand the address allocation of different register types. The following are the common types of Mitsubishi PLC Modbus addresses and their corresponding functions: 1. Coil Register: ...

Mitsubishi Electric CNC numerical control system grounding specification Mitsubishi Electric CNC numerical control system grounding specification

What is the effect of machine tool grounding? 1. Insist that the machine shell and the ground insist on the same voltage. 2. In the event of abnormal external voltage or leakage, the maintenance personnel and the machine tool will not be damaged electrically. 3. Avoid damage to CNC equipment caused by external voltages such as surges. 4. ...

Features of Mitsubishi PLC commonly used models Features of Mitsubishi PLC commonly used models

FX Series PLC: FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in specification mode. In the meantime, the FX series 5U is suitable for any industry, and is used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

The matching relationship between the inverter and the motor - Mitsubishi The matching relationship between the inverter and the motor - Mitsubishi

It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...

Mitsubishi FR-E540 inverter parameter settings Mitsubishi FR-E540 inverter parameter settings

1. Press the mode button continuously until you enter the parameter writing state, and the LED display is: Pr.O 2. Press the upper button to adjust the parameter to the Pr.34O parameter. 3. Press SET, the LED displays the initial value of Pr.340, press ...

Inverter overload fault factor - Mitsubishi inverter Inverter overload fault factor - Mitsubishi inverter

1) The mechanical load is too heavy The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...

There are three major classifications of inverters - Mitsubishi inverters There are three major classifications of inverters - Mitsubishi inverters

There are several ways to classify frequency converters: According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; In accordance with the ...

Mitsubishi servo system failure problem Mitsubishi servo system failure problem

The origin position is incorrect, and the encoder debugs/zeros the bit Replacement bearings, bearing groove wear, rotor cracking, shaft cracking Gear groove wear The magnet bursts steel, the magnet falls, gets stuck and doesn't move Encoder wear, code ...

Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles

TOKYO, March 12, 2020 - Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a compact Light Detection and Ranging (LiDAR) solution that integrates microelectromechanical systems (MEMS) that enable ultra-wide horizontal scanning angles in the self-...

How to configure the mechanical torque period of the inverter - Mitsubishi inverter How to configure the mechanical torque period of the inverter - Mitsubishi inverter

1. The starting torque that makes the mechanical equipment roll from a standstill state is usually positive, and generally larger than the torque required to maintain constant velocity movement, such as most feeders, material conveyors, mixers, mixers, etc., it may reach the additional torque of the Yuan Yuan Yuan Yu Yao Yuan Yuan ...

Mitsubishi PLCFX3U positioning control Mitsubishi PLCFX3U positioning control

Origin regression command with DOG lookup function Mitsubishi PLCFX3U origin regression command with DOG lookup function: DSZR. 1. The workbench runs in the direction of the value reduction of the current value register (generally runs in the opposite direction M8342 ...

Mitsubishi Electric appeared at the 2021 China Smart Expo Mitsubishi Electric appeared at the 2021 China Smart Expo

From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...

Mitsubishi PLC Explanation Notes on the Final Statement Mitsubishi PLC Explanation Notes on the Final Statement

If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...

The protection function of the inverter to the motor - Mitsubishi The protection function of the inverter to the motor - Mitsubishi

The inverter is the control equipment for the operation of the motor, and it has a certain maintenance function for the motor. Most of the inverter appliances have functions such as overvoltage, overcurrent, undervoltage and overload maintenance. Overcurrent maintenance function. In any link of motor acceleration, deceleration and constant speed operation, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top