Mitsubishi FR-E540 inverter parameter settings

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. Press the mode button continuously until you enter the parameter writing state, and the LED display is: Pr.O

                               Mitsubishi FR-E540 inverter parameter settings

2. Press the upper button to adjust the parameter to the Pr.34O parameter.

3. Press SET, the LED displays the initial value of Pr.340, press the upper button to adjust the value of Pr.34O to 2.

4. Continue to press the SET button until Pr.34O is shiny, and then release the button.

5. Press the MODE button continuously until the parameter setting state is returned, and the LED display is Pr.O.

6. Adjust Pr.79 to 1.

7. Press the MODE button continuously until the frequency display status is returned, and the LED display is 0.

8. The parameter setting is completed.

More on that
Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM

Power semiconductor module for 40kW class commercial air conditioner Expansion of the "6th Generation 1200V Large DIPIPM" product lineup Mitsubishi Electric Corporation will sell the power of inverters that drive commercial air conditioners and other products on August 30.

Precautions for the use of Mitsubishi servo motor with brake Precautions for the use of Mitsubishi servo motor with brake

1. Occasions with brake servo motors: The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...

Mitsubishi inverter basic questions and answers Mitsubishi inverter basic questions and answers

1. Question: What is the type of RS485 to RS232C converter used by Mitsubishi inverter for communication? Solution: FA-T-RS40* Mitsubishi inverter is available. 2. Question: Mitsubishi inverter frequency external potentiometer is given, and the external potential recommended to be used ...

Mitsubishi inverter OC causes the failure Mitsubishi inverter OC causes the failure

1. The ERR problem is an under-voltage problem, which is usually caused by the problem of voltage detection loop resistance or wiring, rather than the actual input voltage showing undervoltage. Most of the OC problems of the A200 series are caused by the damage of the drive circuit, and its drive circuit ...

Malfunction caused by capacitance between PLC input lines – Mitsubishi Malfunction caused by capacitance between PLC input lines – Mitsubishi

There is a capacitance between the wires of the cable, and a qualified cable can limit this capacitance to a certain size. It is a qualified cable, when the cable length exceeds a certain length, the capacitance value between the lines will also exceed the required value, when the cable is used for PLC input, the capacitance between the lines will be ...

Mitsubishi PLC floating-point number comparison and arithmetic instruction usage Mitsubishi PLC floating-point number comparison and arithmetic instruction usage

The floating-point arithmetic instruction (FNC110-FNC1320) is used to process floating-point numbers, which are 32 digits and contain 13 instructions such as floating-point number comparison, transformation, four-rule operation, open-squared operation and trigonometric function. All floating-point processing instructions are 32-bit instructions, and when used ...

Mitsubishi PLC and computer communication setup method Mitsubishi PLC and computer communication setup method

After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings". 1. Connect the Mitsubishi PLC to the computer first. 2. Right-click on "My Computer" and select "Handle"...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles. ...

Mitsubishi GM AC Servo MR-JE Mitsubishi GM AC Servo MR-JE

One-click adjustments Servo adjustment can be completed with one-button operation without the need for a computer. In addition, the oscillation button control and robust filter can be automatically adjusted. Instantaneous stop tolerance increases It is equipped with an instantaneous stop TOUGH DRIVE function and a large capacitance ft main circuit capacitor. ...

Inverter life extension method - Mitsubishi Inverter life extension method - Mitsubishi

First, the frequency converter should not be installed on the equipment with a sensation, because the main circuit connection screw in the frequency converter is simply loose, and many frequency converters are damaged due to this reason. Second, the wiring problem: the input end of the inverter is connected to an air The initial maintenance current should not be too large, ...

Mitsubishi PLC control inverter method Mitsubishi PLC control inverter method

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

Mitsubishi servo motor types and advantages Mitsubishi servo motor types and advantages

1. DC servo The structure is simple and easy to operate. However, considering the actual operation, the DC servo motor has introduced mechanical equipment for reversing installation, which increases the cost, has many problems, and is inconvenient to maintain, and often interferes with the production and manufacturing due to the sparks of carbon brushes, and electromagnetic interference will occur. Combine...

The matching relationship between the inverter and the motor - Mitsubishi The matching relationship between the inverter and the motor - Mitsubishi

It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...

Mitsubishi inverter capacity selection points Mitsubishi inverter capacity selection points

The capacity (non-functional) of the Mitsubishi inverter of the drive motor can be understood from the change in energy activity determined by the operating method. 1. When operating at speed or constant speed The efficiency of the inverter is the output current, which is the ...

Mitsubishi PLC password protection settings Mitsubishi PLC password protection settings

In GX Works3, there are three types of security settings: block password, security key, and file password. The block password is for the program to prevent others from reading and writing changes, only for the program; The file password is for the PLC to prevent others from reading and writing changes. Security keys are both capable of ...

Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles

TOKYO, March 12, 2020 - Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a compact Light Detection and Ranging (LiDAR) solution that integrates microelectromechanical systems (MEMS) that enable ultra-wide horizontal scanning angles in the self-...

The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules

The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment. ...

The reason why the computer programming software and the Mitsubishi PLC cannot communicate The reason why the computer programming software and the Mitsubishi PLC cannot communicate

What is the reason why the programming software on the computer and the Mitsubishi PLC cannot communicate? How do I set the port of the communication line? There are several reasons why communication may not be available: 1. It may be that the PLC is not energized; 2. Programming software to create ...

Mitsubishi PLC control inverter method Mitsubishi PLC control inverter method

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

Mitsubishi PLC remote fault diagnosis connection Mitsubishi PLC remote fault diagnosis connection

Mitsubishi PLC is widely used in digital control systems. At present, equipment long-distance control plays an important role in long-distance data collection, PLC long-distance fault diagnosis, and PLC long-distance programming. This article takes the long-distance control of Mitsubishi PLC as an example, and after the HiNet intelligent gateway of Huachen Zhitong ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top