An introduction to the types of data inside the Mitsubishi FX series

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following forms in terms of structure or number system.

                               An introduction to the types of data inside the Mitsubishi FX series

(1) Decimal number

Decimal numbers are also known as word data in PLC. It is primarily present at the set value K of timers and counters; Auxiliary relays, timers, counters, status relays, etc.; timer and counter time value, etc.

(2) Binary numbers

Decimal numbers, octal numbers, hexadecimal numbers, and BCD codes all exist in the form of binary numbers in the PLC. However, when the system operation monitoring is displayed using peripheral devices, it will be restored to the original number system. A binary number is also known as digit data in a PLC. It is mainly found in the contacts and coils of various relays, timers, and counters.

(3) Octal numbers

The address numbers of the input relays and output relays of the FX series PLC are octal.

(4) Hexadecimal numbers

Hexadecimal numbers are used to use operands or actions in instructions.

(5) BCD code

The BCD code is a four-digit binary number that represents its one-digit decimal number. The decimal number in the PLC is often presented in the form of BCD code, and it is also often used in the digital switch in the form of BCD output or the display control of the seven-segment code.

(6) Constants K, H

Constants are an integral part of PLC's internal timers, counters, and usage instructions. The constant K is used to indicate the decimal number, the scale of the 16-bit constant is -32768-+32767, and the scale of the 32-bit constant is -2147483648-+2147483647.

The constant H is used to indicate the hexadecimal number, which includes 16 digits 0-9 and A-F, with the scale of the 16-bit constant being 0-FFFF and the scale of the 32-bit constant being 0-FFFFFFFF.
More on that
Mitsubishi Electric begins research and development of a Mars satellite probe probe Mitsubishi Electric begins research and development of a Mars satellite probe probe

TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...

Mitsubishi PLC selection 5 elements Mitsubishi PLC selection 5 elements

Mitsubishi PLC selection - element 1: IO points The number of ZUI IOs that can be accessed by the Mitsubishi PLC control system. Mitsubishi PLC FX series now commonly used basic unit host is: FX1SFX1N, FX1NC, FX2N, FX2NC, FX3U. FX3UCFX3G, FX5U, 9 series. ...

Mitsubishi PLC control inverter method Mitsubishi PLC control inverter method

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

The difference between the performance of Mitsubishi servo motor and stepper motor The difference between the performance of Mitsubishi servo motor and stepper motor

First, the control accuracy is different The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors with smaller step angles after subdivision. Communicate the control of servo motor ...

Introduction to Mitsubishi Data Backup and Recovery Introduction to Mitsubishi Data Backup and Recovery

In the case of data backup and restoration, the method of batch backup function and the method of individual file input and output function can be used. The following devices can be used for batch backup/rehabilitation. Memory card (front SD card), DS (display unit back SD card), USB memory ...

Mitsubishi inverter parameter setting operation Mitsubishi inverter parameter setting operation

Mitsubishi inverter has many setting parameters, each parameter has a certain selection range, and the use of individual parameters is often improper, resulting in the inverter can not operate normally. Let's take a look at the Mitsubishi inverter parameter setting operation. ...

Mitsubishi PLC has a built-in time adjustment step Mitsubishi PLC has a built-in time adjustment step

1. TWR (Time Write) command Instructions to write time presets to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

Mitsubishi touch screen GT10 series models and their features Mitsubishi touch screen GT10 series models and their features

GT1020 touch screen ● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches ●3-color LED backlight for added visibility ●High brightness liquid crystal, clear under light ● Resolution 160×64, standard memory 512K ●Inside ...

Mitsubishi Electric instruction format Mitsubishi Electric instruction format

(1) Arbitrary axis AC command (G140) G140 Instruction Address = Axis Address Instruction Address = Axis Address ... ; Command Address: Arbitrary Axis AC Command (G140) After that, specify the 1-character address set by the parameter (#12071-#12078) to be used for moving commands, etc.

Three common communication methods of PLC - Mitsubishi Three common communication methods of PLC - Mitsubishi

A PLC network consists of multiple subnets. The communication process of each subnet is determined by the communication protocol. The communication method is the core content of the communication protocol. The means of communication include visit control and data transmission. What are the three common communication methods of PLC? ...

Precautions for the use of Mitsubishi L series PLC terminal cover Precautions for the use of Mitsubishi L series PLC terminal cover

Mitsubishi L series PLC is the same as Q series PLC is a modular PLC, in the specific engineering application, users according to the actual needs of the CPU, power supply, input and output and other special function modules for combination. However, there is a difference between the L series PLC and the Q series PLC in terms of hardware composition.

Mitsubishi PLC keeps the circuit written Mitsubishi PLC keeps the circuit written

There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The holding circuit means that when the external input switch is a button, it can press the button through the holding circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit. ...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

Mitsubishi FX5U series PLC advantages Mitsubishi FX5U series PLC advantages

1. CPU function As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB. 2. Built-in analog input and output (alarm output by the way) Built-in 12-bit 2-channel analog input ...

Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM

Power semiconductor module for 40kW class commercial air conditioner Expansion of the "6th Generation 1200V Large DIPIPM" product lineup Mitsubishi Electric Corporation will sell the power of inverters that drive commercial air conditioners and other products on August 30.

How to configure the mechanical torque period of the inverter - Mitsubishi inverter How to configure the mechanical torque period of the inverter - Mitsubishi inverter

1. The starting torque that makes the mechanical equipment roll from a standstill state is usually positive, and generally larger than the torque required to maintain constant velocity movement, such as most feeders, material conveyors, mixers, mixers, etc., it may reach the additional torque of the Yuan Yuan Yuan Yu Yao Yuan Yuan ...

Classification of Mitsubishi touch screens Classification of Mitsubishi touch screens

At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors. 1. Resistive contact screen The screen body of the resistive contact screen ...

The basic composition of Mitsubishi PLC The basic composition of Mitsubishi PLC

Mitsubishi PLC is composed of power module, CPU module, input module, output module and substrate. Power module: Provides DC5V power supply for each module on the substrate. CPU module: It is the heart of the PLC. The CPU module consists of ...

Mitsubishi PLC commonly used model features Mitsubishi PLC commonly used model features

FX Series PLC: The FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in standard mode. In the meantime, the FX series 5U is suitable for any industry, and is widely used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

Mitsubishi PLC Explanation Notes on the Final Statement Mitsubishi PLC Explanation Notes on the Final Statement

If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top