The bus duct is made of high-quality T2 electrolytic copper as the transmission conductor, which has high purity, high conductivity, low loss and small heating, which is very suitable for industrial and mining enterprises that need to operate with large current loads, but the device of the bus duct produced by Jinzhan Electric must be fixed devices, therefore, it is only suitable for the use of fixed places, and the power cable of the silicone rubber inverter used in the traditional coal mine underground has the following technical characteristics:
High temperature resistance: The cable can reach 180°C for long-term use and 350°C during short circuit.
Physical and mechanical function: the selection of high-strength tear-resistant silicone rubber materials, the tensile strength before aging ≥ 8.5, the crack elongation ≥ 400%, the tensile strength after aging ≥ 6.5, the crack elongation ≥ 250%, and the mechanical function of the product is greatly improved. The busway is fixed, and although the single-section busway is not malleable, it can be assembled and combined to complete long-distance transmission.
Electrical function: It has excellent electrical insulation function, even when the temperature and frequency change or moisture, the electrical insulation function remains stable, in addition, its corona resistance and arc resistance function is good, and the insulation layer can withstand 2-3 times the peak voltage of the system caused by the high harmonic reflection of the frequency conversion system.
Reduce noise and reduce malfunction: The cable structure is compact and the electrical safety is high, which can reduce the adverse effects of high harmonics in the output of the inverter, reduce the noise of the motor, supply overcurrent misoperation maintenance, and improve the torque efficiency of the motor.
Reducing power loss: Divide a traditional neutral wire into three phases, and the three phases induce the directional voltage, integrate the elements of potential imbalance, ensure the consistency of the electric field phase, and the electric field is balanced again to reduce the power loss. Although the price of bus duct is low, the high-quality insulating film is selected in the product, which ensures the stability and reliability of the whole equipment under the premise of compact structure and volume reduction.
Reduction of electromagnetic radiation: Shielding is a method of completing electromagnetic compatibility and reducing electromagnetic radiation. The copper wire is thinly wound and the copper strip is wrapped with a metal shield, and the shielding surface area coverage is 100%, which effectively intercepts the electromagnetic noise propagation path composed of electrostatic coupling, inductive coupling or alternating electromagnetic field coupling through space, separates the ground wire system of the two parts of the circuit, and blocks the possibility of coupling through impedance.
Flexibility: Silicone rubber has special surface self-lubrication and high flexibility, operating in the harsh environment of high temperature and low temperature, the electrical and mechanical functions of the cable are less affected by the change of bending radius and bending frequency.
Acid and alkali resistance: silicone rubber corrosion resistance function is also good, about low concentration of acid, alkali, salt tolerance function is better, such as 10% sulfuric acid in room temperature impregnation for 7 days, volume and component changes are less than 1%, tensile force and cracking elongation basically unchanged.
Environmental protection: Same as bus duct, silicone rubber is harmless and odorless, and is an environmental protection material. The traditional busway shell is made of aluminum alloy material, which is simple, strong and high, saves costs, and can greatly extend the service life of the busway.
|
More on that
|
The Wiener bus is a Siemens 3 VA1 and 3 VA2 adapter
Wiener has developed a new series of 3 VA1 circuit breakers equipped with ® busbar adapters from Siemens in the 160 system with a compact range of 30.
The safety articulation of the circuit breaker is the internal right of the tension spring device base and high-performance rails.
...
|
|
Cooling method for dense busway – Wiener
If the temperature of the dense busway is too high, a fault will occur. For the sake of insurance, it is necessary to know the heat dissipation method of the densely packed busway to prevent the impact of excessive temperature on the busway.
Low-voltage transmission line conductors, wires, cables, branch dense busway, exposed conductive poles, punctured ...
|
|
Specific optimization application of ship unloader bus system - Wiener
1. Bus system 1
The bus adapter used in bus system 1 is more miscellaneous, and -Q1 selects a bus type blocking switch that can be directly attached to the bus; -Q11 is a 3VL2 switch, select an appropriate universal adapter to hook up to the bus; The 3-pole switch-Q12——-Q15 is less than 63A, but ...
|
|
Ship unloader distribution cabinet convergence mode - Wiener
In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.
|
|
Uses and characteristics of detached closed busbar - Wiener
Closing busbars include out-of-phase shut-off buss, co-box (including co-box phase isolation) shut-off busbars and cable busbars, which are used for power plants, substations, industrial and civil power supply leads.
Phase-off busbar
1. Usefulness
Out of phase ...
|
|
Wiener busbar system PT disconnection treatment
The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...
|
|
Busbar system reverse operation – Wiener
(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this time, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a small size, so that when there is a problem with the bus, the bus tie circuit breaker can be quickly tripped, cut off...
|
|
Characteristics of single bus wiring in the switchgear - Wiener
In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to gather, distribute, and transmit electrical energy. The connection methods of the bus bar are ...
|
|
The role of the busbar in the excitation system – Wiener
The bus PT is used to measure the bus voltage on the high-voltage side of the main transformer, and is used to assist in grid connection. Before starting the synchronous grid connection, the excitation system actively adjusts the terminal voltage according to the bus voltage measured by the bus PT, so that the voltage on both sides of the grid-connected switch is basically equal, which is convenient for the same period of grid connection.
...
|
|
The difference between the busbar system and the traditional wiring
The advantages of the busbar system are:
1. The Wiener bus system adopts the bus bar non-perforation connection technology, and the electrical components are firmly connected to the busbar;
2. It saves the device space, saves the redundant wiring, saves the device time and labor;
3. The busbar ...
|
|
The Hazards of Arc Light – Wiener Busbar System
The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects:
(1) The arc temperature is 2 times the appropriate solar temperature, and the large ...
|
|
Precautions for terminal block wiring - Wiener
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.
2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
|
|
The importance of busbar systems in low-voltage switchgear
One of the characteristics of low-voltage switchgear is the multi-functional busbar system.
The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical equipment. The role of the bus is to, sub-...
|
|
Ferromagnetic resonance occurs in the busbar system – Vernal
The ferromagnetic resonance of the bus system is divided into parallel ferromagnetic resonance and series ferromagnetic resonance. Parallel ferromagnetic resonance refers to the resonance of the ground capacitance of the bus system and the nonlinear inductance of the bus electromagnetic voltage transformer (primary neutral grounding) in the neutral point ungrounded system or small current grounding system.
|
|
Low-voltage cabinet for capacitance compensation – Wienal
Capacitor compensation is indispensable in low-voltage cabinets, so what is the effect of capacitor compensation. The meaning of this is that it acts as a capacitor. Let's take a look at the principle of capacitor compensation first, when the capacitor is compensated, the capacitor and the load are connected in parallel, and the capacitor is like a bin. When the load increases, the power supply has internal resistance, so that ...
|
|
Wiener Electric's busbar system escorts the operation of textile machinery equipment
According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...
|
|
Advantages of busbar mounted electrical equipment - Wiener
The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason why we pay attention to it.
First of all, this small electrical appliance set ...
|
|
Scenarios for the use of various types of busbars - Vernal
1. The bus bar is divided into hard bus bar and soft bus bar.
2. According to different shapes, hard busbars can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars, etc.
3. Rectangular busbar is a commonly used busbar. According to its material ...
|
|
The innovation of Wiener 185Power in the low-voltage main distribution system
The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...
|
|
Difference Between Busbar and Cable in Power System – Wiener
Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.
|
|