Q11: What is the maximum number of connecting rods for the rear mounting of P1 and P3?
A: Up to 4 sections can be added, each section is 25mm.
Q12: Does the P switch with SVB in the model come with PE grounding and N-wire terminals?
A: P-switch models with SVB are equipped with PE grounding and N-terminal as standard.
Q13: Can the N-pole attachment and auxiliary contact of the P1 and P3 switches be installed at the same time?
A: 1 standard auxiliary and 1 N-pole module can be installed at the same time.
Q14: Can the ON/OFF switch with a small black handle be replaced with a large padlock handle?
A: Yes. If the customer has previously ordered an ON/OFF switch without the SVB or SVB-SW lettering, the padlock function can also be implemented later by purchasing a separate SVB or SVB-SW handle.
Q15: What is the maximum current of the surface mounted switch?
A: Surface mount is a complete set of products with IP65 protection level mounting box. Its P switch can be up to P3-100, and some T switches can be T8 (275A). For specifications above these currents, the customer must individually select the appropriate cabinet for surface mounting.
Q16: What is the difference between TM switch and T switch?
A: Both are cam switches. Compared with the miniaturization, TM is used to control smaller capacity load circuits, which is small in size and saves more installation space. In addition to the traditional thumb handle operation, the TM series can also be operated with a key head.
Q17: Is there a sign plate for the standard model of T/P switch in Chinese?
A: No. Only: German, English, French, Italian, Portuguese, Spanish and Sweden, etc., other languages need to be customized, or choose blank logo products, by the customer DIY.
Q18: Does Eaton have a P switch for distribution cabinet mounting?
A: Yes. Eaton has the P1 and P3 series of switchboard mounts with extension rods for currents up to 100A. Metal extension rods are available in lengths suitable for 400mm and 600mm cabinet depths. The operating handle is available in SVB series and K series, which can be flexibly selected.
Q19: What is the IP65 protection level of T/P?
A: The IP65 protection level promised by Eaton, except for the surface mounting method with the box, refers to the protection level that can be achieved on the front side of the switch after the specified installation, not all directions. For surface mounting, when the customer opens the knock-out hole of the box to open the wiring, the corresponding protection level of the glander must be installed to meet the standard.
Q20: What is the scope of product certification for T/P switches?
A: There is no 5-hole specification, there is a 6-hole specification.
Q21: Can the mounting bracket M22-A4 be compatible with the single head of the M22 button and indicator light?
A: As a global production line, T/P switches have all the international mainstream certifications. Such as: CE, VDE, UL, CSA, CCC and all kinds of ship inspection certifications.
|
More on that
|
Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply
Generation and transmission of electromagnetic interference
There are two ways of electromagnetic interference transmission: one is conducted transmission and the other is radiated transmission. Conducted transmission is a complete circuit connection between the interference source and the sensitive equipment, and the interference signal is transmitted to the receiver along the connected circuit.
|
|
Tianyi switch - maintenance of disconnector switch
1) Clean the dust on the surface of the porcelain, check whether the surface of the porcelain is glazed or damaged, whether there are cracks and flashover marks, and whether the iron and porcelain joints of the insulator are firm. If the damage is severe, it should be replaced;
2) Wipe the oil stains on the blades, contacts or fingers with gasoline and check the contact ...
|
|
Tianyi button indicator - button indicator induction circuit fault and solution
First, the reason for the fault of the induction circuit of the switch button indicator
1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light.
2. Sense ...
|
|
Tianyi switch - the reason why the air switch trips and cannot be pushed
1. What is the reason why the empty trip cannot be pushed?
1. If the air opening itself is faulty or damaged, the air opening should be replaced with a new one.
2. If the line is caused by a short circuit, the line should be found first, and then reconnected.
|
|
Tianyi switch - the difference between high-voltage load switch and high-voltage circuit breaker
1. The high-voltage load switch can be used as a load switch, which has the effect of self-extinguishing arc, but its breaking volume is very small and very limited.
2. The high-voltage isolation switch generally cannot be used as a load switch. There is no arc extinguishing cover in the structure, and there are also disconnectors that can switch loads on and off, but the structure is different from load switches ...
|
|
What should be paid attention to in the design of Tianyi switch - switching power supply?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
Tianyi switch - the use of dual power transfer switch
1. Install the dual power transfer switch with the power supply to ensure the correct access of the power supply.
2. Adjust the handle of the dual power transfer switch to the "automatic" position, so that the power supply will automatically detect the state of the other power supply, when one of the power supplies fails, the other power supply will ...
|
|
Tianyi switch - classification and application of dual power transfer switch
The dual-power automatic transfer switch is mainly used in the emergency power supply system, which automatically switches the load circuit from one power supply to another (standby) power supply switching appliance to ensure the continuous and reliable operation of important loads. Therefore, the dual-power automatic transfer switch is often used in important places of electricity consumption.
|
|
Tianyi switch - the switching mode of dual power transfer switch
Conversion conditions: The purpose of requiring dual power supplies is to complete the automatic and reliable conversion of dual power supplies under "specific" circumstances. This "specific condition" is the conversion premise of the dual power supply, or the conversion condition, which is the primary consideration for choosing the dual power supply.
A. In the event of a power failure ...
|
|
Tianyi switch - the classification of dual power transfer switches
It is mainly divided into ATS and STS.
STS static toggle switch
STS (Static Transfer Switch), also known as static transfer switch. The STS automatically switches to the second channel to supply power to the load after the first channel fails.
|
|
Tianyi switch - the difference between C type and D type of air switch
The meaning is different, the scope of application is different, and the role is different.
Air opening C represents the current, and the D model represents the power. The scope of use is different. If it is a household electricity, the air switch of the C model is generally chosen. The role is different. Type C it is used for home lighting use, Type D is suitable for ...
|
|
Tianyi switch - what is the function of high-voltage load switch
1. It can isolate the power supply, with a significant disconnection point, and is mostly used for fixed high-voltage devices;
2. It has arc extinguishing equipment and a certain opening and closing rate, and can pass through the normal working current and the specified short-circuit circuit in the case of closing;
3. It is forbidden to connect and cut off the circuit with load, ...
|
|
Tianyi switch - switching power supply failure and maintenance method
1. No output, the fuse is normal This phenomenon indicates that the switching power supply is not working or has entered the protection state. First of all, it is necessary to measure whether the starting pin of the power control chip has a starting voltage, if there is no starting voltage or the starting voltage is too low, it is necessary to check whether the starting resistance and the external components of the starting pin are ...
|
|
Tianyi switch - the role of low-voltage isolation switch
1. Through the isolation switch, it plays a good insulating role, so that the whole circuit can be safe and secure, and the maintenance personnel or staff also have enough ability to repair the circuit.
2. At the same time, the low-voltage isolation switch can also change the operation mode of the circuit, which is used in the power plant or gas plant.
|
|
The main features of VTeam X42 series limit switches
Uses: X42 series limit switches can be widely used in various types of mechanical equipment, automatic assembly lines and other light and medium load occasions, can detect the object action state, such as presence and absence, movement position, end of stroke, etc.
Overview: The switch is mainly composed of switch operating parts, ...
|
|
Tianyi switch - the classification of proximity switches and their introduction
(1) Eddy current proximity switch
This type of switch is sometimes called an inductive proximity switch. It is the use of conductive objects when they are close to the proximity switch to produce eddy currents inside the object. This eddy current reacts to the proximity switch, causing the internal circuit parameters of the switch to change, so as to identify the presence or absence of ...
|
|
Tianyi switch - the use conditions and applicable places of low-voltage isolation switch
1. The basic conditions for the use of low-voltage isolation switches
(1) The altitude does not exceed 1000 meters;
(2) The ambient temperature is not higher than +40°C and not lower than -40°C;
(3) The relative humidity is not more than 85% (relative to +20±5°C).
2. The low-voltage isolation switch is not suitable for the following ...
|
|
Tianyi switch - 9 tests and methods for switching power supply
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Tianyi switch - the use and function of air switch
What are the uses of air switches
1. The air switch is an important electrical appliance in the low-voltage distribution network and power drive system, which integrates control and a variety of protection functions. In addition to completing contact and breaking circuits, it can also generate short circuits to circuits or electrical equipment. Severe...
|
|
Tianyi switch - the installation method of the limit switch
1. First open all the packages of the newly bought limit switch, confirm that the parts in each package are not missing and complete, and then discharge all the parts in turn.
2. Then open the body part of the limit switch, as long as you loosen the screws with a screwdriver.
|
|