Uses: X42 series limit switches can be widely used in various types of mechanical equipment, automatic assembly lines and other light and medium load occasions, can detect the object action state, such as presence and absence, movement position, end of stroke, etc.
Overview: The switch is mainly composed of three parts: switch operating parts, transmission parts and contact box. All switch contacts are double break contacts and their normally closed contacts are affirmatively open. According to the mechanical principle of contact opening and disconnecting, it can be divided into two types: peristaltic type (H) and quick action type (S). The technical specifications of X42 series limit switches fully meet the indicators of international electrical standards. The high performance of the switch in terms of mechanical life, protection level, electrical performance, switching time accuracy and repeatability ensures the safety of the machine and equipment.
Durable: The X42 series limit switch housing is made of high-performance reinforced flame retardant nylon, which has strong impact resistance, and all switch rocker arms are treated with anti-rust treatment for durability.
High protection level: Different industrial environments require limit switches to have high protection performance, X42 series limit switches have a protection level of IP65, which can be used normally under various harsh environmental conditions.
Easy to install: The X42 series limit switch can be fixed on the machine equipment with two screws, which is very easy to install.
Flexible and maneuverable: A series has 12 kinds of actuators, which can meet the needs of users in different occasions, and all actuators can be rotated 90 degrees in four directions. The maximum deflection of the swing arm is 270 degrees, and the swing arm and the rotating shaft are toothed and occlusive, and the angle can be adjusted by 10 degrees.
Long life: X42 series limit switch has the characteristics of long life, the mechanical life of the switch can reach 5 million times, and the electrical life can be greater than 500,000 times.
High precision: X42 series limit switch has high round-trip accuracy and switching time accuracy.
Double Break Contacts: All switch contacts are double break contacts, the contact material is made of silver alloy, and the circuit isolation between the contacts ensures that the product has high safety performance.
Convenient wiring: the switch box cover is locked by the clamping mechanism, no need to fix the screws, and only one action is needed to open the box cover or close the box cover when wiring, which is simple and convenient
|
More on that
|
Tianyi switch - the difference between high-voltage load switch and high-voltage circuit breaker
1. The high-voltage load switch can be used as a load switch, which has the effect of self-extinguishing arc, but its breaking volume is very small and very limited.
2. The high-voltage isolation switch generally cannot be used as a load switch. There is no arc extinguishing cover in the structure, and there are also disconnectors that can switch loads on and off, but the structure is different from load switches ...
|
|
Tianyi Button Signal Light - Color Classification of Signal Indicator and Its Meaning
(1) Green (HG, GL)
What it means: stands for Safety, Normal, Readiness (i.e., an indication under safe operating conditions or the readiness of a mechanical device to start).
Function: It is often used to indicate the state of equipment ready to start, all auxiliary components are in a state of preparation for operation, and various parts ...
|
|
Tianyi switch - the classification of dual power transfer switches
It is mainly divided into ATS and STS.
STS static toggle switch
STS (Static Transfer Switch), also known as static transfer switch. The STS automatically switches to the second channel to supply power to the load after the first channel fails.
|
|
Tianyi switch - the classification of proximity switches and their introduction
(1) Eddy current proximity switch
This type of switch is sometimes called an inductive proximity switch. It is the use of conductive objects when they are close to the proximity switch to produce eddy currents inside the object. This eddy current reacts to the proximity switch, causing the internal circuit parameters of the switch to change, so as to identify the presence or absence of ...
|
|
Tianyi button signal light - how to choose and use the button indicator light
How to use the indicator color correctly?
1. The indicator light (also known as the signal light) is mainly used to attract the attention of the operator or instruct the operator to carry out a certain operation in the way of bright indication, and as an indication that a certain state or instruction is being executed or has been executed.
2. General ...
|
|
Tianyi switch - dual power supply automatic transfer switch normal working conditions
1) Ambient air temperature: The upper limit of ambient air temperature is +40°C, the lower limit of ambient air temperature is -5°C, and the average value of ambient air temperature for 24h does not exceed +35°C
2) Altitude: The altitude of the installation site does not exceed 2000m.
3) Atmospheric conditions: Atmospheric relative humidity in the surrounding air ...
|
|
Tianyi switch button - the color meaning of the button and indicator light and the place of use
1. Buttons
1. Red
Operation in hazardous situations. It is often used for emergency stops
Stop and break. It is often used to stop all machines, stop one or more motors, stop a certain part of a piece of equipment, make the electrical components lose power, and have a stop function reset button.
...
|
|
Tianyi switch - introduction to the characteristics of high-voltage load switch
1. It can isolate the power supply, have obvious disconnection points, and is mostly used for fixed high-voltage equipment.
2. It has an arc extinguishing device and a certain opening and closing speed, and can pass the normal working current and the specified short-circuit circuit in the closing state.
3. It is strictly forbidden to turn on and off the circuit with load.
|
|
Tianyi switch - the performance and main features of dual power automatic transfer switch
performance
1. Adopt double-row composite contacts, cross-connected mechanisms, micro-motor pre-energy storage and micro-electronic control technology, basically achieve zero arcing (no arc extinguishing cover);
2. Adopt reliable mechanical interlocking and electrical interlocking technology;
3. Adopt zero-crossing technology;
4、 ...
|
|
What should be paid attention to in the design of Tianyi switch - switching power supply?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
Tianyi switch - an introduction to the common types of low-voltage switches
1. Frame circuit breaker (universal type) - ACB:
Rated current: In principle, frame circuit breakers are required for rated currents above 630A, and molded case circuit breakers are generally below 630A. It can be seen that the rated current of the frame circuit breaker is much larger, generally 630A-6300A. In addition in segments can ...
|
|
Tianyi switch - the main accessory of the air switch
Internal accessories
Auxiliary contact: The auxiliary contact is the contact mechanically linked by the main circuit of the circuit breaker, which is mainly used for the display of the circuit breaker opening and closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, to ...
|
|
Tianyi switch - the role of air switch
1. The air switch is an important electrical appliance in the low-voltage distribution network and power drive system, which integrates control and a variety of protection functions. In addition to completing contact and breaking circuits, it can also generate short circuits to circuits or electrical equipment. Protection against severe overloads and undervoltages, etc.
|
|
Tianyi switch - the operation precautions of the disconnector switch
(1) Before operation, check that the circuit breaker (switch) is in the opening position accordingly to prevent the isolation switch from being pulled and closed with load.
(2) There is a locking device to prevent misoperation between the knife switch, the grounding knife switch and the switch, and the reverse operation must be carried out in order. If it is locked and cannot be operated, ...
|
|
Overview of limit switches and their functions - Tianyi limit switches
An overview of limit switches
Limit switch is a kind of mechanical orientation and electronic control interface, the mechanical action into electrical signals, is suitable for industrial environment of a common electromechanical and electrical components, through the contact way to detect the object, the existence and so on. It is possible to control the device's ...
|
|
Tianyi switch - how to select the switch?
1. Use less plastic switches
The switch is composed of a panel, a current carrier, a nozzle and a base, etc., and a good switch is mostly made of stainless steel inlay, which is safe and anti-electric shock. On the contrary, most of the inferior switches are made of plastic, although they are insulated, they are prone to leakage and flammability, and potential safety hazards will occur.
2 ...
|
|
Tianyi switch - routine detection of air switch
The socket, lamp head, kitchen, bathroom, refrigerator, air conditioner of each route should be put out separately, and each route should have a separate air switch, high-power rooms, such as kitchens and bathrooms, the line of more than 4 square millimeters should reach 20A, and the general lamp head line should only be 16A, and each line ...
|
|
Tianyi switch - maintenance of disconnector switch
1) Clean the dust on the surface of the porcelain, check whether the surface of the porcelain is glazed or damaged, whether there are cracks and flashover marks, and whether the iron and porcelain joints of the insulator are firm. If the damage is severe, it should be replaced;
2) Wipe the oil stains on the blades, contacts or fingers with gasoline and check the contact ...
|
|
Tianyi switch - the principle of electromagnetic interference generation and three control technologies of switching power supply
Generation and transmission of electromagnetic interference
There are two ways of electromagnetic interference transmission: one is conducted transmission and the other is radiated transmission. Conducted transmission is a complete circuit connection between the interference source and the sensitive equipment, and the interference signal is transmitted to the receiver along the connected circuit.
|
|
Tianyi switch - the characteristics and classification of load isolation switch
First, the characteristics of the load switch
A load switch is a switchgear between a circuit breaker and an isolation switch. It has a simple arc extinguishing device, which can cut off the rated load current and a certain overload current, but cannot cut off the short-circuit current
Second, the classification of load switches
According to the operating voltage ...
|
|