1. Install the dual power transfer switch with the power supply to ensure the correct access of the power supply.

2. Adjust the handle of the dual power transfer switch to the "automatic" position, so that the power supply will automatically detect the state of the other power supply, and when one of the power supplies fails, the other power supply will automatically replenish the power supply.

3. If you want to switch the power supply manually, adjust the handle to the "manual" position, and then adjust the handle to the "A" or "B" position to realize the power switching.

4. If you don't need to use the dual power transfer switch, you can adjust the handle to the "OFF" position, so that you can disconnect the connection between the dual power transfer switch and the power supply.
Tianyi switch - the use of dual power transfer switch

More on that
Tianyi button indicator - button indicator induction circuit fault and solution Tianyi button indicator - button indicator induction circuit fault and solution

First, the reason for the fault of the induction circuit of the switch button indicator 1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light. 2. Sense ...

Tianyi switch - introduction to the types and characteristics of limit switches Tianyi switch - introduction to the types and characteristics of limit switches

Conventional domestic travel switch LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.

Tianyi switch - the difference between switching power supply and linear power supply Tianyi switch - the difference between switching power supply and linear power supply

(1) The cost of linear power supply is higher than that of switching power supply at a certain output power point. Therefore, with the development and innovation of power electronics technology, the switching power supply technology continues to break through and innovate.

Tianyi switch - dual power supply automatic transfer switch operating procedures Tianyi switch - dual power supply automatic transfer switch operating procedures

1) When there is a power outage for any reason and the power cannot be restored in a short period of time, the backup power supply must be activated 1. Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet in the distribution room, and the mains power supply cut-off of the dual power switching box), and pull the double-cast anti-reverse switch to the side of the self-provided power supply to ensure that the power supply is protected.

Tianyi switch - the operation precautions of the disconnector switch Tianyi switch - the operation precautions of the disconnector switch

(1) Before operation, check that the circuit breaker (switch) is in the opening position accordingly to prevent the isolation switch from being pulled and closed with load. (2) There is a locking device to prevent misoperation between the knife switch, the grounding knife switch and the switch, and the reverse operation must be carried out in order. If it is locked and cannot be operated, ...

Tianyi switch - maintenance of disconnector switch Tianyi switch - maintenance of disconnector switch

1) Clean the dust on the surface of the porcelain, check whether the surface of the porcelain is glazed or damaged, whether there are cracks and flashover marks, and whether the iron and porcelain joints of the insulator are firm. If the damage is severe, it should be replaced; 2) Wipe the oil stains on the blades, contacts or fingers with gasoline and check the contact ...

Tianyi switch - the performance and main features of dual power automatic transfer switch Tianyi switch - the performance and main features of dual power automatic transfer switch

performance 1. Adopt double-row composite contacts, cross-connected mechanisms, micro-motor pre-energy storage and micro-electronic control technology, basically achieve zero arcing (no arc extinguishing cover); 2. Adopt reliable mechanical interlocking and electrical interlocking technology; 3. Adopt zero-crossing technology; 4、 ...

Tianyi switch - the difference between disconnector and circuit breaker Tianyi switch - the difference between disconnector and circuit breaker

1. The circuit breaker is equipped with an arc extinguishing device, so the circuit breaker can be operated with load, but it cannot operate the current of the load. The disconnector does not have an arc extinguishing device, and it can operate places where the load current is less than 5A, but it is generally not suitable for operation with load. 2. And the circuit breaker ...

Tianyi switch - classification and application of dual power transfer switch Tianyi switch - classification and application of dual power transfer switch

The dual-power automatic transfer switch is mainly used in the emergency power supply system, which automatically switches the load circuit from one power supply to another (standby) power supply switching appliance to ensure the continuous and reliable operation of important loads. Therefore, the dual-power automatic transfer switch is often used in important places of electricity consumption.

VTeam switch – how to operate a linear DC power supply correctly VTeam switch – how to operate a linear DC power supply correctly

1) Voltage Setting: Turn on the DC switch, adjust the voltage knob to adjust the voltage reading to the desired operating power connection. If you need to lower the voltage, turn the potentiometer slowly so that the drip rate of the voltmeter is compatible with the speed of the manual adjustment knob. 2) Constant Current Setting: Connect ...

Tianyi switch - the precautions required for the operation of dual power automatic transfer switch Tianyi switch - the precautions required for the operation of dual power automatic transfer switch

1. When closing, first of all, attention should be paid to check that the circuit breaker that can be connected to the dual-power automatic transfer switch is indeed in the opening position, and then quickly operate the risk isolation switch to close it (whether the enterprise adopts manual management agency or leveraged financial institution personnel operation), but ...

Tianyi switch - the use and function of air switch Tianyi switch - the use and function of air switch

What are the uses of air switches 1. The air switch is an important electrical appliance in the low-voltage distribution network and power drive system, which integrates control and a variety of protection functions. In addition to completing contact and breaking circuits, it can also generate short circuits to circuits or electrical equipment. Severe...

Tianyi switch - the method of adjusting the current of Tianyi switch Tianyi switch - the method of adjusting the current of Tianyi switch

1. Change the reference current of the feedback module Regulating the reference current is the most basic way to regulate the output current of a switching power supply, and it can usually be achieved by rotating a potentiometer or toggling a switch. Changing the reference current allows the magnitude of the feedback current to be compared with it, so as to control the switch ...

Tianyi switch - the role of the disconnector switch Tianyi switch - the role of the disconnector switch

1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment. 2. According to the operation needs, change the line. 3. It can be used to divide and combine small currents in the line, ...

Tianyi switch - the selection principle of air switch Tianyi switch - the selection principle of air switch

1. Determine the type and protection form of the circuit breaker according to the requirements of the line for protection - determine the selection of frame type, device type or current limiting type. 2. The rated voltage UN of the circuit breaker should be equal to or greater than the rated voltage of the protected line. 3. The rated voltage of the circuit breaker undervoltage tripper ...

Tianyi switch - routine detection of air switch Tianyi switch - routine detection of air switch

The socket, lamp head, kitchen, bathroom, refrigerator, air conditioner of each route should be put out separately, and each route should have a separate air switch, high-power rooms, such as kitchens and bathrooms, the line of more than 4 square millimeters should reach 20A, and the general lamp head line should only be 16A, and each line ...

Tianyi switch - introduction to the characteristics of high-voltage load switch Tianyi switch - introduction to the characteristics of high-voltage load switch

1. It can isolate the power supply, have obvious disconnection points, and is mostly used for fixed high-voltage equipment. 2. It has an arc extinguishing device and a certain opening and closing speed, and can pass the normal working current and the specified short-circuit circuit in the closing state. 3. It is strictly forbidden to turn on and off the circuit with load.

Tianyi switch - what are the functions of limit switches? Tianyi switch - what are the functions of limit switches?

1. Protection The most important role of the limit switch must be its protection effect, the limit switch is also known as the travel limit switch, which is mainly used to control the stroke of mechanical equipment and limit protection. In practice, the travel limit switch is installed in a pre-arranged position, and the travel limit switch is installed in a pre-arranged position.

Tianyi switch - introduction to the type of disconnector switch Tianyi switch - introduction to the type of disconnector switch

According to the different ways in which it is installed It can be divided into outdoor disconnector and indoor high-voltage disconnector. Outdoor disconnector refers to the disconnector that can withstand wind, rain, snow, filth, condensation, ice and heavy frost, etc., and is suitable for installation on terraces. According to the different structures of its insulating pillars ...

VTeam participated in the 9th China CNC Machine Tool Exhibition VTeam participated in the 9th China CNC Machine Tool Exhibition

During the "Twelfth Five-Year Plan" period, China deepened reform and opening up and accelerated the transformation of economic development mode. Transformation and upgrading is the only way for the sustainable development of the machine tool industry, and the top priority of the industry's transformation and upgrading is to enhance the market competitiveness of high-end CNC machine tools. Exhibitors will take advantage of the CCMT ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top