Tianyi switch - the installation method of the limit switch

Create Date: 2024-8-30 12:03:23|Source: TIANYI/TAYEE

1. First open all the packages of the newly bought limit switch, confirm that the parts in each package are not missing and complete, and then discharge all the parts in turn.

2. Then open the body part of the limit switch, as long as you loosen the screws with a screwdriver, you will see a metal baffle after opening, and you can pry it up with a flathead screwdriver.

3. Pry until a right-angle head can be stuffed in, the metal baffle must be raised, otherwise it will not be plugged in, after fixing the position, press the baffle back to its original position, and press it down directly with your thumb.

4. At the bottom of the installation, the outlet should be aligned with the card slot and plugged in, then the cover should be covered, and then a toothed gear plate should be installed on the right-angle head, and then the pole should be installed, and the screw should be tightened to complete the installation of a limit switch, and the sound of internal contact will be heard when the metal rod is dialed back and forth.
Tianyi switch - the installation method of the limit switch

More on that
Tianyi switch - dual power supply automatic transfer switch operating procedures Tianyi switch - dual power supply automatic transfer switch operating procedures

1) When there is a power outage for any reason and the power cannot be restored in a short period of time, the backup power supply must be activated 1. Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet in the distribution room, and the mains power supply cut-off of the dual power switching box), and pull the double-cast anti-reverse switch to the side of the self-provided power supply to ensure that the power supply is protected.

Tianyi switch - the difference between high-voltage load switch and circuit breaker Tianyi switch - the difference between high-voltage load switch and circuit breaker

1. The high-voltage load switch can be broken with load and has the function of self-extinguishing arc, but its breaking capacity is very small and limited. 2. The high-voltage isolation switch is generally not able to break with load, there is no arc extinguishing cover in the structure, and there is also an isolation switch that can break the load.

VTeam switch – how to operate a linear DC power supply correctly VTeam switch – how to operate a linear DC power supply correctly

1) Voltage Setting: Turn on the DC switch, adjust the voltage knob to adjust the voltage reading to the desired operating power connection. If you need to lower the voltage, turn the potentiometer slowly so that the drip rate of the voltmeter is compatible with the speed of the manual adjustment knob. 2) Constant Current Setting: Connect ...

Tianyi switch - the role of air switch Tianyi switch - the role of air switch

1. The air switch is an important electrical appliance in the low-voltage distribution network and power drive system, which integrates control and a variety of protection functions. In addition to completing contact and breaking circuits, it can also generate short circuits to circuits or electrical equipment. Protection against severe overloads and undervoltages, etc.

Tianyi switch - the principle and main purpose of transfer switch Tianyi switch - the principle and main purpose of transfer switch

1. Principle The contact system of the transfer switch consists of several moving contacts embedded in the insulated housing with a static contact base and a movable support. The moving contact is a double-break butt contact bridge, which turns the circuit on or off with the rotating shaft of the rotating shaft attached to different positions. Positioning...

Overview of limit switches and their functions - Tianyi limit switches Overview of limit switches and their functions - Tianyi limit switches

An overview of limit switches Limit switch is a kind of mechanical orientation and electronic control interface, the mechanical action into electrical signals, is suitable for industrial environment of a common electromechanical and electrical components, through the contact way to detect the object, the existence and so on. It is possible to control the device's ...

Model introduction of Tianyi cam switch Model introduction of Tianyi cam switch

LW42 series LW42 series cam switch and safety switch are another series of high-quality products announced by Shanghai Tianyi Electric Appliance Co., Ltd. to meet customer needs. Device function: personal safety is paramount, LW42 series cam switch and safety switch unique terminal plan ...

Tianyi switch - the difference between switching power supply and linear power supply Tianyi switch - the difference between switching power supply and linear power supply

(1) The cost of linear power supply is higher than that of switching power supply at a certain output power point. Therefore, with the development and innovation of power electronics technology, the switching power supply technology continues to break through and innovate.

What are the common problems of Tianyi switch - disconnector? What are the common problems of Tianyi switch - disconnector?

1. What are the common faults? Answer: The common faults of the disconnector are: (1) The contact part is overheated. (2) Porcelain insulation damage and flashover discharge. (3) Refuse to pull and close. (4) Wrong pulling and closing. 2. The overheating of the contact part of the disconnector during operation is caused by ...

Tianyi switch - how to choose the right industrial switching power supply? Tianyi switch - how to choose the right industrial switching power supply?

1. First of all, it is necessary to select the appropriate input voltage specification; 2. Choose the right power. In order to extend the service life of the power supply, it is necessary to select an additional type with 30% of the rated output power. 3. Consider the load characteristics. The load added is a motor, bulb or capacitive load, and the current at start-up ...

Tianyi switch - the air switch is always the reason for tripping Tianyi switch - the air switch is always the reason for tripping

1. The current value of the air switch is too low, and the load power is greater than the rated power of the air switch. 2. The load joint is not firm, and the joint is not compressed. 3. If there is a short circuit in the line, check whether the electrical plug is dry. 4. The line is aging and leaking, resulting in both the live wire and the neutral line.

Tianyi switch - precautions for high-voltage load switch Tianyi switch - precautions for high-voltage load switch

1. For vertical installation, the switch frame, closing mechanism, cable sheath, and protective steel pipe should be reliably grounded (not connected in series). 2. Before operation, several no-load opening and closing operations should be carried out, and each rotating part should be free of jamming, closing in place, and there should be enough safety distance after opening. ...

Tianyi switch - the precautions required for the operation of dual power automatic transfer switch Tianyi switch - the precautions required for the operation of dual power automatic transfer switch

1. When closing, first of all, attention should be paid to check that the circuit breaker that can be connected to the dual-power automatic transfer switch is indeed in the opening position, and then quickly operate the risk isolation switch to close it (whether the enterprise adopts manual management agency or leveraged financial institution personnel operation), but ...

Tianyi switch - the characteristics of low-voltage isolation switch Tianyi switch - the characteristics of low-voltage isolation switch

1. When overhauling electrical equipment, provide an electrical interval and a visible disconnection point to ensure the personal safety of maintenance personnel. 2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided or combined with load current and short circuit current.

Tianyi button indicator - button indicator induction circuit fault and solution Tianyi button indicator - button indicator induction circuit fault and solution

First, the reason for the fault of the induction circuit of the switch button indicator 1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light. 2. Sense ...

Tianyi switch - common faults and troubleshooting methods of low-voltage switches Tianyi switch - common faults and troubleshooting methods of low-voltage switches

1 The contact is overheated Contact heat is mainly caused by the current flowing through the contact, and there is power loss between the contacts (such as contact resistance loss, arc energy loss). It is normal for the contacts to heat up, but severe heat (overheating) is a malfunction. The main ...

Tianyi switch - a measure to reduce the ripple and noise voltage of the switching power supply Tianyi switch - a measure to reduce the ripple and noise voltage of the switching power supply

Reduces EMI interference The metal shell is used as a shield to reduce the interference of external electromagnetic field radiation. To reduce electromagnetic interference from the power line input, an EMI filter is added to the power supply input.   At the output, capacitors with good high-frequency performance and low ESR are used The use of polymer solids ...

Tianyi switch - precautions for switching power supply to regulate current Tianyi switch - precautions for switching power supply to regulate current

1. Pay attention to stability When adjusting the output current of the switching power supply, the stability of the circuit must be ensured, otherwise there will be current fluctuations, disturbances and other phenomena, which will affect the normal operation of electronic equipment. Therefore, it is necessary to perform a ...

Tianyi switch - the use conditions and applicable places of low-voltage isolation switch Tianyi switch - the use conditions and applicable places of low-voltage isolation switch

1. The basic conditions for the use of low-voltage isolation switches (1) The altitude does not exceed 1000 meters; (2) The ambient temperature is not higher than +40°C and not lower than -40°C; (3) The relative humidity is not more than 85% (relative to +20±5°C). 2. The low-voltage isolation switch is not suitable for the following ...

What should be paid attention to in the design of Tianyi switch - switching power supply? What should be paid attention to in the design of Tianyi switch - switching power supply?

1. Wiring The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top