Analysis of PLC and inverter connection problems - Mitsubishi
When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1. PLC switch command signal input
Inverter input ...
|
|
Mitsubishi PLC's method of controlling the inverter
1. Mitsubishi PLC's analog signal control inverter
Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...
|
|
Mitsubishi inverter overload fault judgment method
1. Check whether the three-phase electricity of the motor is balanced
(1) If the three-phase voltage of the motor is unbalanced, then check whether the three-phase voltage at the output end of the Mitsubishi inverter is balanced.
(2) If the three-phase voltage of the Mitsubishi inverter is also unbalanced, the problem is inside the Mitsubishi inverter, and it should be investigated.
|
|
Mitsubishi servo motor alarm code and processing skills
1. Mitsubishi servo drive alarm code AL31.1
Fault analysis: It is the motor overspeed alarm.
Cause analysis: 1. The frequency of a single pulse of the input command is too high;
2. The acceleration and deceleration time is too small, resulting in overshoot and too large;
3. Mitsubishi servo system is unstable;
4. Electricity ...
|
|
The weight conversion method of the Mitsubishi weigh module
Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...
|
|
Electronic gear ratio calculation for Mitsubishi servo motors
When calculating the electronic gear ratio of the Mitsubishi servo motor, the first thing to pay attention to is to check whether your Mitsubishi servo motor has been directly set to XX pulse one turn, if this parameter is not directly set, we can go through a simple formula to calculate the electronic gear ratio of the Mitsubishi servo motor.
...
|
|
Application of Mitsubishi FX PLC in speed measurement
[Example] a motor is equipped with an optical encoder (the optical encoder is coaxially installed with the motor), and the FX2N-32MT is used to measure the speed of the motor.
【Solution】
Because the photoelectric encoder is coaxially installed with the motor, the ...
|
|
MITSUBISHI COLLABORATIVE ROBOT MELFA ASSISTA
With the popularization of industrial robots in the production site, more and more Mitsubishi collaborative robots, Mitsubishi robots, MELFA ASSISTA, RV-5AS-D on-site issues need to be solved urgently, such as the need for more robot programming engineers, adding labor costs; The teaching is cluttered, and a large number of non-...
|
|
Troubleshooting methods for Mitsubishi overload
1. Check whether the motor is heated
If the temperature rise of the motor is not high, the first thing to check is whether the electronic thermal protection function of the Mitsubishi inverter is preset reasonably, if the Mitsubishi inverter still has margin, the preset value should be relaxed; For example, the allowable current of Mitsubishi inverter is now out of margin, not ...
|
|
The difference between the measurement of ordinary motors and inverter motors - Mitsubishi
1. The actual output waveform of the inverter is PWM wave, which contains carrier signals in addition to the fundamental wave. The carrier signal frequency is much higher than that of the fundamental wave, and it is a square wave signal, which contains a lot of higher harmonics, and the test system requires a higher sampling frequency and bandwidth.
...
|
|
Mitsubishi servo selection robot method
When evaluating which process is suitable for which process to use in the production environment, it is necessary to carefully consider the problem you want to solve and consider all the costs that the robot can save: reduce waste, improve power, improve yield, improve safety or reduce labor costs. These costs ...
|
|
Mitsubishi PLC FAQs
1. How to connect a PNP three-wire proximity switch to the input port of FX3U PLC.
Answer: The signal output termination of the PNP three-wire system close to the switch is connected to the input port of the PLC, such as X0, and the 0V end of the PNP type close switch to the 0V terminal on the PLC, and the S/S terminal and the 0V terminal ...
|
|
Mitsubishi servo drive system requirements
Servo drive system requirements
1. Wide speed regulation
2. High positioning accuracy
3. Satisfactory transmission rigidity and high speed stability
4. Fast response, no overshoot
In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...
|
|
There are three major classifications of inverters - Mitsubishi inverters
There are several ways to classify frequency converters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
In accordance with the ...
|
|
Mitsubishi servo motor method
1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...
|
|
Mitsubishi PLC's communication inspection method
When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port.
...
|
|
Mitsubishi FX1N switching power supply fault repair
Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged).
Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.
|
|
How to adjust the jitter phenomenon of Mitsubishi servo motor
(1) Prerequisites
Mitsubishi servo motors are able to improve the inertia of the motor by adjusting the gain, so as to adapt to the load, but the Mitsubishi servo motor is able to improve endlessly. Under normal circumstances, it is considered that it can withstand within 10-15 times of the additional inertia of the motor, and Mitsubishi reducer is required to be added in addition. We know ...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. Whereas...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation simulation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load on the motor shaft is less than 2.5Nm, ...
|