Pilz switches – how to install safety switches

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm.

2) The socket must be facing the switch panel direction left to the zero wire, the right to the live wire, the upper end of the three-hole grounding wire, and the box is not allowed to have exposed copper wires, three-phase sockets, and protective wires to the upper end.

3) The switch panel should be easy to use after installation. The same plane switch in the same room must be arranged on the same horizontal line and in the order most commonly used.

4) The wire behind the switch panel socket should be straightened out and placed in the bottom box in a wavy shape.

5) The wiring on the switch panel adopts the insertion crimping method, the wire end is stripped of the 10mm insulation layer, and the terminal hole is inserted and pressed with a bolt, if the terminal hole is large or the bolt is slightly shorter, the wire can not be compressed, the wire head can be stripped off and folded into a double wire insertion.

6) The switch panel should be installed in the live wire. When there are multiple switches on a panel, each switch should be wired separately, the wires on each switch should be threaded separately, and several switches should have several inlet pipes connected to the junction box. Turn off the light when you pull the switch up. When the rocker switch is installed, there is a red dot facing up, be careful not to install it in reverse, and press the lower half of the rocker to open.

7) Multiple sockets on a switch panel, some of which have been wired with edge pieces; Some sockets are split and need to be connected in parallel with a short wire. The live wire, the neutral wire and the ground wire in the socket should be connected according to the specified position and cannot be connected wrongly.

When installing the switch panel, press the connected wire and the wire connector in the junction box in the box, buckle the panel on the junction box, and fix the panel on the box with screws. When fixing, pay attention to the panel should be flat. It should not be skewed, and it should be tightly buckled on the wall, and there should be no gaps. After fixing the lower panel with screws, cover the decorative surface.
Pilz switches – how to install safety switches

More on that
What should I pay attention to when using Pilz safety switches in series? What should I pay attention to when using Pilz safety switches in series?

When using Pilz safety gate switches in series, the following points need to be noted: 1. The installation position of the switch must meet the design requirements of the safety gate control system to ensure that no accidents will occur during operation. 2. When connecting the circuit, it should be in accordance with the ...

Pilz: a product that can travel all over the world Pilz: a product that can travel all over the world

Whether Pilz products are to be used in Canada, Italy or China, Pilz customers do not have to worry about the required certifications.   The various quality marks on the products show that customers can rely on Pilz, for example in the modular safety relay myPNOZ: 1. By sticking ...

Peel magnetic relays – testing of relays Peel magnetic relays – testing of relays

(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open. (2) Coil resistance: multimeter R...

Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association

The "Safety Standardization" theme exhibition organized by the China Machinery Industry Safety and Health Association and the National Machinery Safety Standardization Technical Committee was unveiled at the China Yiwu International Commodities (Standards) Expo held from November 24 to 27, 2022. Automation specialist Pilz was invited to participate in the exhibition to demonstrate ...

PILZ WILL BE EXHIBITING AT THERMPROCESS 2023 PILZ WILL BE EXHIBITING AT THERMPROCESS 2023

From June 12 to June 16, 2023, Pilz will be present at the THERMPROCESS trade fair in Düsseldorf, Germany, at booth B10 in Hall 9. Germany Düsseldorf Thermprocess is Germany most important trade fair for industrial furnaces and heat treatment ...

Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5 Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5

PNOZ s5 belongs to the PNOZSigma family and is a safety relay with a time-delay function There are 8 terminal blocks on the top and bottom of the module, where: A1 and A2 are the terminal blocks of the module power supply; S11 and S12 are terminal blocks for a set of safety input channels; S21 and ...

An overview of Pilz safety switches, their advantages and application areas An overview of Pilz safety switches, their advantages and application areas

Optimal safety gate and position monitoring via safety switches Safety switch Safety switches can be used in a variety of applications: When the guards are opened, dangerous machine movements must be stopped and restarts must be prevented. These guards must be prevented from failing or being manipulated. ...

PILZ presents the new base module PNOZmulti2 – PNOZ m B0.1 PILZ presents the new base module PNOZmulti2 – PNOZ m B0.1

In terms of functionality and cost-effectiveness, it is more suitable for customer needs of small and medium-sized security applications. "Similarities and differences" between PNOZ m B0 and PNOZ m B0.1 Similar to PNOZ m B0, the base module body of PNOZ m B0.1 offers 20 safe digital inputs that can be freely combined.

Classification of Pilz safety relays Classification of Pilz safety relays

Safety relays from PNOZ – a classic In 1987, Pilz was a milestone in the development of the world's first emergency stop safety relay to protect people and machines. PNOZ has also become synonymous with safety relays and is used by customers all over the world. The full range ...

Pilz launches the maintenance system "Key in Pocket" Pilz launches the maintenance system "Key in Pocket"

The new maintenance system "key in pocket" from Pilz prevents the risk of unauthorised machine restarts and increases the safety of maintenance work. Digital maintenance assurance is based on the access authorization system PITreader, which ensures the safety of machinery and industrial information.

Pilz's second-generation safety radar system is born Pilz's second-generation safety radar system is born

Radar technology is ubiquitous in our lives, from the surveillance radar on the car to the safety radar on the industry, the purpose is to make the dangerous equipment have the ability to detect the surrounding moving objects, and effectively remind and brake when the moving objects are found to be approaching. The Pilz Safety Radar has been ...

Safety circuit requirements for Peel magnetic relays Safety circuit requirements for Peel magnetic relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the safety circuit of the machine, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm the safety of the transmission such as safety switches, light curtains, etc.

How Pilz safety relays are shorted to I10 points How Pilz safety relays are shorted to I10 points

Short-circuit method: when FD is displayed, it means that the safety loop is disconnected, at this time, the safety relay CC is disconnected, and the indicator light on the operation board is extinguished, first check whether the safety loop power supply fuse 1F1 (the 6th from the left in the lower row behind the control cabinet) is fused; Second, when the maintenance needs to be shorted, please ...

Maintenance method of Germany PILZ Peel magnetic relay Maintenance method of Germany PILZ Peel magnetic relay

Maintenance method: 1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Introduction and benefits of Pilmagnetic security locks Introduction and benefits of Pilmagnetic security locks

The use of safety locks If there are hazards in the equipment, such as moving levers, rotating mechanisms or even robots, in order to avoid damage to the operator, a safety gate system will be added to the protective cover (door). Safety door interlocking devices are widely used in the field of industrial safety. ...

Pilz: Here comes an alternative to tagout lockout Pilz: Here comes an alternative to tagout lockout

The repair and maintenance of industrial field equipment is inevitable, and the most embarrassing thing for field personnel is that the equipment is started while the person is still in the danger area. In this scenario, personnel are highly vulnerable to serious injuries from moving parts, harmful gases, harmful rays, and high temperatures. Listing...

Pilz: Safety in the production of lithium-ion batteries Pilz: Safety in the production of lithium-ion batteries

With the rapid rise of new energy vehicles, the lithium battery industry has also ushered in explosive growth. The production process of lithium battery is more complex, and the production process of different battery types is also different, but the manufacturing process is roughly the same, which is the front process (pole piece production), the middle ...

Pilz releases version 1.23 of the automation system PSS 4000 Pilz releases version 1.23 of the automation system PSS 4000

The automation system PSS 4000 from Pilz is the ideal solution for safe production. The automation system PSS 4000 can be individually configured to meet the actual requirements.   Version 1.23 of the PSS 4000 has been released, which includes the following important new features ...

Pilmagnetic switches – what are the requirements for a fixed safety switch? Pilmagnetic switches – what are the requirements for a fixed safety switch?

1. The fastener itself needs to be reliable and stable enough. 2. Need to rely on special tools to remove, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases they can be easily fitted with fingernails or on the go.

Pilz PSEN safety sensor technology Pilz PSEN safety sensor technology

In combination with the safety controller, safety sensor technology from PSEN gives you the protection you covered! . Contactless magnetic safety switch PSENmag Magnetic switches can be used to monitor the position of mobile guards and are also suitable for difficult to precisely guide doors, which are susceptible to strong shocks.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top