PILZ presents the new base module PNOZmulti2 – PNOZ m B0.1

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

In terms of functionality and cost-effectiveness, it is more suitable for customer needs of small and medium-sized security applications.

"Similarities and differences" between PNOZ m B0 and PNOZ m B0.1

Similar to PNOZ m B0, the base module body of PNOZ m B0.1 offers 20 safe digital inputs that can be freely combined, of which 8 safety input points can also be used as non-safe semiconductor outputs via software configuration. The body is capable of providing four safety semiconductor outputs, each up to ISO 13849-1 PL e and ISO 61508 SIL CL3. In addition, there are four test pulses on the main body that can be used to monitor the safety input loop, and these four test pulses can be configured as non-safety semiconductor outputs through software configuration. In terms of dimensions, PNOZ m B0.1 and PNOZ m B0 are identical. Chip-card removable program storage facilitates future hardware exchange. The backlit LCD display on the front shows the faults and status of the operating PNOZ m B0.1 module, as well as custom text that can be configured by the user software.
PILZ presents the new base module PNOZmulti2 – PNOZ m B0.1
  In contrast to PNOZ m B0, only one safe I/O module can be extended to the right side of the base module of PNOZ m B0.1 (not supported by the speed monitoring module), e.g. PNOZ m EF 16DI, PNOZ m EF 4DI4DOR, PNOZ m EF 2DOR, PNOZ m EF 4DI4DORD, PNOZ m EF 8DI4DO, PNOZ m EF 8DI2DOT. On the left, up to 4 safety connection modules, 1 fieldbus module, and 1 ETH or RS232 interface module can be expanded as required.

PNOZmulti Configurator is still available as PNOZmulti Configurator, but v11.0 onwards and can be used with all common security software function blocks. PNOZmulti Configurator is known to be very user-friendly, with a graphical interface, drag-and-drop mouse operation and menu-based selection, which makes it easy to implement professional security programming even without much programming experience. The extensive fieldbus interface modules enable PNOZ m B0.1 to easily exchange data with external third-party devices, and to easily access and display all types of diagnostic data from the safety system, which currently supports protocols such as Profibus, CANopen, CC-Link, EtherCAT, EtherNet/IP, Profinet and Powerlink.
PILZ presents the new base module PNOZmulti2 – PNOZ m B0.1
  The features of PNOZ m B0.1 at a glance

Only one safe I/O module can be expanded on the right, making it suitable for small and medium-sized applications

Commonly used safety functions such as emergency stop buttons, safety doors, safety light curtains, etc. can be monitored

The 45mm outline width saves the installation space of the electrical cabinet, and the built-in illuminated LCD screen increases the flexibility of diagnosis

The accompanying software tool PNOZmulti Configurator saves a lot of planning and engineering time thanks to its user-friendly interface, rich function blocks, graphical operation and menu-based selection

A wide range of third-party fieldbus interfaces are supported, such as Profinet, Ethernet/IP, EtherCAT, Profibus, etc

For users, the launch of the basic module PNOZ m B0.1 enriches the choice of safety controllers, and when the number of safety functions required by the device can be met using PNOZ m B0.1, the choice of PNOZ m B0.1 is obviously more cost-effective.

More on that
Characteristics and functions of Pilz safety door switches Characteristics and functions of Pilz safety door switches

Pilz safety relays, safety laser scanners, pilz modules, PSEN safety switches, encoders and safety gate gratings are the characteristics of pilz safety door switches in Germany. The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. ...

Pilmagnetic switches – what are the properties of safety switches? Pilmagnetic switches – what are the properties of safety switches?

The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...

Pilz: Safety control solution for SIL4 at rail level crossings Pilz: Safety control solution for SIL4 at rail level crossings

On fully enclosed rail transit lines, viaducts or tunnels are usually used to avoid the impact of rail lines on the distance, while on non-fully enclosed rail transit lines, the plane intersection between the railway and the distance, that is, level crossings, is more common. In the early stage, rail transit ...

Pilz: Visualisation solution based on PNOZmulti2 Pilz: Visualisation solution based on PNOZmulti2

Visualization solution PASvisu with OPC UA interface Pilz is expanding its web-based visualisation solution PASvisu: From the new version 1.3 onwards, the OPC UA interface can be connected to the small controller PNOZmulti and other control systems. Use...

Pilz at the Hannover Messe 2019 Pilz at the Hannover Messe 2019

Adhering to the motto "Weautomate.Safely." From April 1 to 5, 2019, Pilz will once again present innovative automation solutions at the Hannover Messe in Hall 9, Stand D17. As a safe automation ...

Peel magnetic relay - how to reset the safety relay alarm? Peel magnetic relay - how to reset the safety relay alarm?

1. Check the alarm cause of the relay, if there is a fault, reset the relay urgently, and replace the relay in time. 2. Check whether there is a protection alarm in the control system, if there is a protection alarm, the cause of the alarm will be eliminated, and the protection alarm system will be reset according to the corresponding steps. ...

Pilz: Guard locking and safety interlocks in functional safety Pilz: Guard locking and safety interlocks in functional safety

In machinery safety, if it is an access door that prevents entry into the hazardous movement area, it is usually necessary to use a safety interlock switch to realize the "linkage" between the access door and the movement of the hazardous equipment, and when the access door is opened, the dangerous movement stops. In some cases, it is also necessary to prevent the access door from being hit.

Pierre Switches – An introduction to the basics of safety switches Pierre Switches – An introduction to the basics of safety switches

Features of the safety door switch: The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...

Pilz - Presentation of the features of the safety relay PNOZ s60 Pilz - Presentation of the features of the safety relay PNOZ s60

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features. PNO ...

Pilz: IEC 62443 – Industrial Information Security Standard (Part II) Pilz: IEC 62443 – Industrial Information Security Standard (Part II)

In the context of industrial automation, the term "safety" refers to the functional safety of equipment, which means that people and the environment are protected from damage from foreseeable coercion from machines, and the residual risk is more or less always present, but the residual risk cannot exceed the acceptable level. Through the use of security relay ...

Pilz: Safe monitoring of cardboard feeds for packaging machines Pilz: Safe monitoring of cardboard feeds for packaging machines

Pilz supports manufacturers and operators of packaging machines in the implementation of packaging automation. As a well-known and trusted provider of machinery safety services to companies worldwide. Use the myPNOZ modular safety relays The first ...

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Top 5 reasons to choose myPNOZ from Pilz Top 5 reasons to choose myPNOZ from Pilz

Pilz's modular safety relay myPNOZ has received a lot of attention and acceptance since its introduction. It has been nominated for the Hermes Award, the Germany Innovation Award (GIA) and the Red Dot Design Award. This safety app, which can be customized and mass-produced according to user requirements, can be customized according to user requirements.

Peel magnetic relays – the characteristics and working principle of relays Peel magnetic relays – the characteristics and working principle of relays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the electrical appliances that make the output circuit to be controlled on or off can be divided into two categories: electrical quantity (such as current, voltage, frequency, power, etc.) relays and non-electric (such as temperature, pressure, speed, etc.) relays.

Pierz switches – what are the properties of safety switches? Pierz switches – what are the properties of safety switches?

The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...

Pilz: Determined by the harmonised service provider of EU standards Pilz: Determined by the harmonised service provider of EU standards

EU standards have no legal significance in themselves. However, it acquires legal status after publication in the Official Journal of the European Union or citation in domestic laws and regulations. The publication of these harmonized standards will result in a "presumption of conformity". As a result, users who adopt the standard can assume that their actions are in compliance with laws and directives. If it happens ...

Pierre Switches – Requirements for securing safety switches Pierre Switches – Requirements for securing safety switches

The fastener itself needs to be reliable and stable enough. It can be removed with specialized tools, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases these screws can be easily punched with nails or carry-on equipment.

Peel magnetic relay - how to remove the safety relay reset alarm Peel magnetic relay - how to remove the safety relay reset alarm

The safety relay disconnects the circuit in use, and at this time, the safety relay is broken, or the safety relay detects unsafe factors and disconnects the circuit, and it is necessary to make an accurate judgment. 1. If there is a potential safety hazard in the circuit, after eliminating the hidden danger, restart the safety relay, ...

Peel magnetic relay - the wiring method, function and application of time relay Peel magnetic relay - the wiring method, function and application of time relay

Wiring method of time relay 1. Control wiring You think of it as a DC relay. 3. 7 is used to connect to 12V control voltage; 2. 7 is used to connect to 24V control voltage. 7 of them are used as the negative electrode of direct current, which is connected to the neutral line when used. 2. Connect to a 220V live wire. 2 ...

Pilz: Machinery safety retrofit at the Heineken brewery Pilz: Machinery safety retrofit at the Heineken brewery

Brau Union is a beer production company from Austria that belongs to the famous beer brand Heineken Group, which supplies more than 5 million liters of beer per year. The company's largest brewery is in Wieselburg, which accounts for one-fifth of the year's beer supply. Within the Heineken Group, the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top