Pilmagnetic switches – what are the requirements for a fixed safety switch?

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

1. The fastener itself needs to be reliable and stable enough.

2. Need to rely on special tools to remove, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases they can be easily opened with fingernails or personal equipment.

3. Fasteners need to prevent themselves from loosening, and the necessity of elastic washers or screw glue should be considered when appropriate.

4. It is necessary to prevent damage caused by foreseeable external impacts, and judge the installation position according to the actual situation, such as the horizontal plane where people often walk and forklifts often pass.

5. The mechanical switch needs to be carried out within the specified operating range, especially for the mechanical deadbolt, its length is fixed, if the installation distance is not calculated, it is easy to cause physical damage to the switch if the operation is not calculated.

6. The safety door switch is not allowed to be used as a mechanical stop and mechanical stop for protection, and it is also to avoid damage to the switch body and operating head, reduce unnecessary physical impact as much as possible, and prevent safety failure and service life reduction.
Pilmagnetic switches – what are the requirements for a fixed safety switch?

More on that
Peel magnetic relay - the cause and solution of the fault of the high voltage relay Peel magnetic relay - the cause and solution of the fault of the high voltage relay

1. Some common faults of high-voltage relay coils 1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected. 2 ...

Pierre Switches – An introduction to the basics of safety switches Pierre Switches – An introduction to the basics of safety switches

Features of the safety door switch: The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...

Peel magnetic relays - characteristics and principles of use of safety relays Peel magnetic relays - characteristics and principles of use of safety relays

The fundamental characteristics of safety relays: Feature 1, can be used in some automatic control occasions: safety relay - a kind of equipment that can control safety, this equipment is very easy to use in the automatic control field. Generally, there are emergency stops or safety doors, as well as safety gratings and other input devices.

Pilz: It's easy to build your own customised safety relay Pilz: It's easy to build your own customised safety relay

The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience. ...

Peel magnetic relays - analysis of common faults and causes of relays Peel magnetic relays - analysis of common faults and causes of relays

1. Contact failure (1) The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion and pit formed on the contact bite each other), fusion welding, or cold welding. (2) The contact wear of the relay is caused by the absence of arc extinguishing devices or measures, or improper parameter selection, ...

Pilz: Evaluation of AGV application scenarios Pilz: Evaluation of AGV application scenarios

As one of the core equipment of intelligent factory logistics, mobile handling robots play an important role in the factory logistics automation system. The AGV is equipped with an automatic guided vehicle, which can ensure that the system can be flexible and changeable along the ...

Pilz will be exhibiting at the Hannover Messe 2022 Pilz will be exhibiting at the Hannover Messe 2022

At the Hannover Messe 2022 at the Industrial Fair (30 May 2022 * 2 June), Pilz will be presenting complete automation solutions including security and industrial security that can be automated independently and flexibly. Visitors can enjoy a tour of the Peel ...

Pilmagnetic switch – the role of a load switch Pilmagnetic switch – the role of a load switch

1. Breaking and closing. Because it has a certain arc extinguishing ability, it can be used to break and close the load current and the overload current of a certain multiple (usually 3-4 times) of the small stem; It can also be used to break and close a no-load transformer with a larger capacity than the disconnector allows, a longer no-load line ...

Pilz: IEC 62443 – Industrial Information Security Standard (Part II) Pilz: IEC 62443 – Industrial Information Security Standard (Part II)

In the context of industrial automation, the term "safety" refers to the functional safety of equipment, which means that people and the environment are protected from damage from foreseeable coercion from machines, and the residual risk is more or less always present, but the residual risk cannot exceed the acceptable level. Through the use of security relay ...

Peel magnetic relay - introduction to the characteristics of high and low voltage relays Peel magnetic relay - introduction to the characteristics of high and low voltage relays

1. High-precision detection: high and low voltage relays can detect high and low voltage signals with high precision, and realize accurate monitoring and control of electrical equipment. 2. Large capacitance switch: High and low voltage relays have good durability and stability when switching high capacitance loads. ...

Peel magnetic relays – the five major classifications of relays Peel magnetic relays – the five major classifications of relays

1. Classification by use In terms of use, the classification of relays can be divided into two types: control relays and protection relays. In the meantime: thermal relays, overcurrent relays, and undervoltage relays are all protective relays. And moment relays, speed relays, intermediate relays ...

Peel magnetic relay - relay common faults and solutions Peel magnetic relay - relay common faults and solutions

First, the contact is loose and cracks The contact is the electrical touch part of the relay to complete the switching load, and the contact of some products is riveted and pressed, and its primary disadvantage is that the contact is loose, the contact cracking or the scale azimuth error is too large. This will affect the touch reliability of the relay. ...

How to use Pilz safety relays How to use Pilz safety relays

When using Pilz safety relays, it is necessary to pay attention to the correct way to use them. The key to the correct use of safety relays is to protect the wiring method of the input circuit. In general, the wiring method of the safety relay is divided into three types.

Pilz: Machinery safety retrofit at the Heineken brewery Pilz: Machinery safety retrofit at the Heineken brewery

Brau Union is a beer production company from Austria that belongs to the famous beer brand Heineken Group, which supplies more than 5 million liters of beer per year. The company's largest brewery is in Wieselburg, which accounts for one-fifth of the year's beer supply. Within the Heineken Group, the ...

What should I pay attention to when using Pilz safety switches in series? What should I pay attention to when using Pilz safety switches in series?

When using Pilz safety gate switches in series, the following points need to be noted: 1. The installation position of the switch must meet the design requirements of the safety gate control system to ensure that no accidents will occur during operation. 2. When connecting the circuit, it should be in accordance with the ...

The Pilz automation system PSS 4000 assists in railway braking tests The Pilz automation system PSS 4000 assists in railway braking tests

The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...

How Pilz replaces the safety switch How Pilz replaces the safety switch

1. First, unscrew out the fixing screws of fixing the noodle frame and the water baffle plate according to the above steps; 2. Unscrew out the two screws that fix the safety switch, and pull out the two lead pins connecting the safety switch; 3. Replace the new safety switch and assemble it according to the original steps. Electrical safety switch ...

Pilz: Safe monitoring of cardboard feeds for packaging machines Pilz: Safe monitoring of cardboard feeds for packaging machines

Pilz supports manufacturers and operators of packaging machines in the implementation of packaging automation. As a well-known and trusted provider of machinery safety services to companies worldwide. Use the myPNOZ modular safety relays The first ...

Pilz: Can safety gate switches be used in series? Pilz: Can safety gate switches be used in series?

Recently, the "core shortage problem" has been plaguing major industrial control brand manufacturers, from safety PLCs and inverters, to safety door locks, etc., generally because of the lack of chips, resulting in longer delivery times, and some even unable to deliver the goods at all. This has created a "difficult problem" for the friends in the electrical design department.

Pilz will be exhibiting at LogiMAT 2023 Pilz will be exhibiting at LogiMAT 2023

From April 25 to 27, at the LogiMAT international logistics trade fair in Stuttgart, Germany, Pilz will present its safe and complete AGV safety automation solutions.   At Pilz's booth in Hall 6 – A21, visitors to the show will experience how AGVs are considering ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top