Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

The automation system PSS 4000 from Pilz is the ideal solution for safe production. The automation system PSS 4000 can be individually configured to meet the actual requirements.
Pilz releases version 1.23 of the automation system PSS 4000
  Version 1.23 of the PSS 4000 has been released and includes the following important new features:

Record process data to enhance troubleshooting

The controller records its process data using the tracking function and saves it on an SD card. This simplifies troubleshooting and enables you to track the chronological order of variable values, such as braking curves. This helps you optimize your processes. You can view the recorded variable values via the PASscope tool. In the new version, PASscope is automatically installed together with PAS4000. The tracking function is available for PSSu H PLC2 FS SN SD (-T) and PSSu H FS2 SN SD (-T) devices, as well as for PSS 4000 firmware from version 1.23.0 onwards.
Pilz releases version 1.23 of the automation system PSS 4000
  SafetyNET p communication is configurable

The real-time Ethernet SafetyNET p is used for the transfer of process data between PSS 4000 devices. You can now configure the response time or network load for SafetyNET p communication in the PAS4000. For example, the optimization of the network load increases the scalability of the PSS 4000 system.

New software module: FS_MSO_PITreader_Visu

The module FS_MSO_PITreader_Visu for the control and monitoring of the selection device (Pilz operator terminal with visualisation software PASvisu) together with the PITreader to control access rights. When the module is called up in the PAS4000, the safety functions (e.g. light curtains or safety gates) required for the selected operating mode must be activated. The main functions of this module are:

Read check permissions from PITreader (security ID, permissions, error status)

Control display and manipulation elements on the visualization system

Read and inspect data from the visualization system

Output data to the visualization system

Generate and output diagnostic information

Output Safe Operating Mode (MSO)

Automatic project licensing

Projects can now be automatically licensed when they are downloaded. If you select this option, you no longer need to manually license a project after it changes. This is provided that the project has already been manually authorized once and that there must be sufficient project credits (PASunits) available.

More on that
Peel magnetic relays – what is the difference between a relay and a contactor Peel magnetic relays – what is the difference between a relay and a contactor

1. The effect is not the same: The primary effect of the relay is: signal detection, transmission, conversion or disposal, the circuit current it is on and off is generally small, and it is generally used in the control circuit to control weak signals. The primary effect of the contactor is to turn on or off the main circuit. Host...

Peel magnetic relays - an introduction to the classification of relays and their functions Peel magnetic relays - an introduction to the classification of relays and their functions

1. The role of intermediate relays It plays the role of converting and transmitting control signals, that is to say, its input signal is the energizing and power-off signal of the coil, and the output signal is the contact action of the intermediate relay. Essentially, it is a type of voltage relay ...

Peel magnetic relays - characteristics and principles of use of safety relays Peel magnetic relays - characteristics and principles of use of safety relays

The fundamental characteristics of safety relays: Feature 1, can be used in some automatic control occasions: safety relay - a kind of equipment that can control safety, this equipment is very easy to use in the automatic control field. Generally, there are emergency stops or safety doors, as well as safety gratings and other input devices.

Peel magnetic relays – what are the ways in which the contacts of relays are used? Peel magnetic relays – what are the ways in which the contacts of relays are used?

There are 3 basic forms of relay contacts: (1) The two contacts are disconnected when the dynamic type (normally open, H-type) coil is not energized, and the two contacts are closed after the energizing is applied. It is represented by the pinyin prefix "H" of the word "合". (2) Dynamic breaking type (normally closed, D-type) coil is not energized when the two contacts ...

Pilz: Safety control solution for SIL4 at rail level crossings Pilz: Safety control solution for SIL4 at rail level crossings

On fully enclosed rail transit lines, viaducts or tunnels are usually used to avoid the impact of rail lines on the distance, while on non-fully enclosed rail transit lines, the plane intersection between the railway and the distance, that is, level crossings, is more common. In the early stage, rail transit ...

Pilz: Configurable safety control systems for the filling industry Pilz: Configurable safety control systems for the filling industry

With the progress of the industrial level and the improvement of people's safety awareness, more and more attention has been paid to the safe operation of equipment in the workshop. As a professional supplier of safe automation solutions, Pilz's safety products are used in a wide range of industries. Configurable safety control system PNOZmulti ...

Peel magnetic relays – a common fault of electromagnetic relays Peel magnetic relays – a common fault of electromagnetic relays

1. After the power failure, the armature cannot be released immediately, which may be due to the stuck movable core, the core air gap is too small, the spring strain and the oil caused by the core contact surface, etc. Universal relay maintenance should be treated differently by the cause of failure, or adjust the air gap to protect it from 0.02 to 0.05 mm, ...

Peel magnetic relay - the cause and solution of the fault of the high voltage relay Peel magnetic relay - the cause and solution of the fault of the high voltage relay

1. Some common faults of high-voltage relay coils 1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected. 2 ...

Pilz: The solution for the safe operation of AGVs Pilz: The solution for the safe operation of AGVs

As one of the core equipment of smart factory logistics, automatic guided vehicles (AGVs) play an increasingly important role in the factory logistics automation system. They travel through the warehouse and complete the handling task efficiently, which brings great convenience to the production, but also has certain safety hazards.

Peel magnetic relay - fault judgment and treatment method of safety relay Peel magnetic relay - fault judgment and treatment method of safety relay

1. Determine whether the safety relay itself is faulty: 1. Separate from the three circuits of short-circuit S10/S12, S11/S12, S21/S22. 2. Turn on the 24V power supply (A1 is positive, A2 is negative), and the Power light should be on at this moment; 3. Reset the S33/S34 terminals, and the K1 and K2 lamps ...

Piermagnetic switches – an introduction to the functions of safety switches Piermagnetic switches – an introduction to the functions of safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Pilz conducts brake tests on freight trains Pilz conducts brake tests on freight trains

The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...

How Pilz safety relays work How Pilz safety relays work

PILZ SAFETY RELAYS GENERALLY CONSIST OF AN IRON CORE, COILS, ARMATURES, CONTACT REEDS, ETC. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction to ...

REASONS FOR USE OF PILZ SAFETY RELAYS REASONS FOR USE OF PILZ SAFETY RELAYS

Why can't ordinary relays be used in safety-related applications? Ordinary relays use the mechanical action of coils and metal contacts to switch loads. Metal contacts may be fusion welded due to repeated operations. Once this happens, the machine will also be ...

Pilz - Presentation of the features of the safety relay PNOZ s60 Pilz - Presentation of the features of the safety relay PNOZ s60

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features. PNO ...

Pilz is a multi-functional furnace management and control system Pilz is a multi-functional furnace management and control system

Thermal energy utilization is very common in today's industrial fields, such as metal thermoprocessing, food baking, paint drying, grain drying, glass/plastic melting, fiber hair removal, etc. The sources of heat energy used in these fields are usually in 2 forms: 1 is the conversion of electrical energy into thermal energy ( ...

Pilz: Become a certified expert in industrial security Pilz: Become a certified expert in industrial security

Industrial security has become an integral part of automation, but with new requirements and specifications, manufacturers, integrators, and operators are faced with the question of how their employees can meet the new challenges. In response, Pilz has launched a new safety training course that can help students learn ...

IEC 62443 – Industrial Information Security Standard – Pilz IEC 62443 – Industrial Information Security Standard – Pilz

The development of IT technology is changing all walks of life, automation is no exception, the degree of networking of production equipment and the use of standard protocols such as Ethernet for physical transmission of data has greatly increased, standardized protocols such as OPC UA allow access to controllers through IT systems, making data communication changeable.

Introduction to the functions of PMC EZ servo motors Introduction to the functions of PMC EZ servo motors

There are many applications that you can achieve with PMC EZ servo motors. Their compact design is a convincing feature that also makes them ideal for space-critical applications. In addition, you benefit from high dynamics and low cogging torque.   Servo motor PMC EZ ...

Pilz has launched the new stand-alone base module PNOZ m C0 Pilz has launched the new stand-alone base module PNOZ m C0

In the safe configurable small controller series PNOZmulti 2 from Pilz, a new stand-alone base module PNOZ m C0 is now available. PNOZ m C0 has the structural characteristics of a safety relay, but it is just as powerful as a safety controller. It offers 8 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top