The given way of the inverter - LS generates electricity

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Frequency given meaning and given method

The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal, and the so-called frequency giving method is the method of supplying the given signal of the inverter.

                               The given way of the inverter - LS generates electricity

The frequency of the inverter is mainly given by the following methods: panel operation, input digital port, analog signal, pulse signal and communication method. Each of these given methods has its own advantages and disadvantages, and must be selected on a case-by-case basis. The selection of a given method is determined by setting the frequency of the frequency of the frequency and the given parameters of the inverter.

Frequency-given method parameter picking

The frequency given method of the inverter can be divided into panel operation given and external port given. External port is divided into digital port given, analog port given and communication interface given. (Panel operation is also communication given).

It can also be divided into digital and analog. Analog quantity is further divided into voltage and current.

In general, the general inverter only uses one given method to output the frequency, but in some cases it is also possible to output the frequency with two given methods, and the output frequency is the superposition of the frequencies given by the two methods.

The selection of a given method is generally completed by the configuration of the port and the setting of the frequency setting parameters.

More on that
DC motor troubleshooting - LS power generation DC motor troubleshooting - LS power generation

1. The speed of the motor slows down, and the cause of the problem of sound disorder may occur in the electronic speed stabilization device and the motor itself. If there is no problem with the power supply, most of the motor itself has a problem. It can be repaired by replacing the new motor and dismantling and repairing the motor. Dismantling and repairing the motor ...

The working principle of LS PLC module The working principle of LS PLC module

When LS PLC is put into operation, its operation process is generally divided into three stages: input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the ...

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Calculation method of filter capacitance value of inverter Calculation method of filter capacitance value of inverter

Alternating current can be converted into direct current using rectifier electricity, but in three-phase electricity, this DC voltage or current contains voltage or current ripple with a frequency of six times the frequency of the power supply. In addition, the inverter inverter will also generate ripple voltage or current due to output and carrier frequency, etc., and reverse ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

Inverter circuit board repair and drawing-free maintenance method - LS power generation Inverter circuit board repair and drawing-free maintenance method - LS power generation

1. Be "confident" It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...

Inverter load test run step - LS power generation Inverter load test run step - LS power generation

1. Manually operate the work stop button of the inverter panel, investigate the work stop process of the motor and the display window of the inverter to see if there is any abnormal phenomenon. 2. If the inverter presents an overcurrent maintenance action during the process of starting P to abort the motor, ...

Several basic functions of the inverter - LS generates electricity Several basic functions of the inverter - LS generates electricity

The inverter mainly has the following functions: 1. Soft up The direct launch of the inverter motor will have a severe impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits.

Introduction of LS power products Introduction of LS power products

1. Power-related products: medium, low and high voltage electrical products; (1) Low Voltage Products: Molded Case Circuit Breaker, Air Circuit Breaker, LS Contactor & Overload Relay, Miniature Circuit Breaker, Dual Power Automatic Transfer Switch, Intelligent Motor Protector, Manual Motor Starter, Surge Protection ...

The five stages of mastery of PLC technology The five stages of mastery of PLC technology

One. Logical stage   The so-called logical stage is to be able to complete the general logical planning in the relay system, since it is a relay system, so the knowledge of power drag is the foundation of this stage. I personally summarize that the root of learning the relay system lies in the word "grab", the relay system ...

The basic problem of LS electric molded case circuit breaker The basic problem of LS electric molded case circuit breaker

Rated current of LS molded case circuit breaker: Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...

Methods for extending the service life of inverters - LS generates electricity Methods for extending the service life of inverters - LS generates electricity

1. The influence of electromagnetic disturbance on the inverter: In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...

LS Electric helps Cisco Smart City build an industry benchmark LS Electric helps Cisco Smart City build an industry benchmark

In March 2019, LS Group signed a strategic cooperation agreement with Country Garden to build Cisco Smart City into an innovative model for smart cities. LS Electric will provide power distribution system solutions for Cisco (Guangzhou) Smart City, providing frame circuit breakers, molded case circuit breakers, vacuum circuit breakers, miniature circuit breakers, and micro circuit breakers.

The difference between inverter and power saver - LS produces electricity The difference between inverter and power saver - LS produces electricity

First, the frequency conversion skill is only one of the many power-saving skills, including voltage regulation and current limiting, power factor compensation, phased power regulation, frequency conversion, chopping, filtering, energy feedback and other skills, even if the power saver using the principle of frequency conversion is concerned, the frequency converter is only power-saving.

The cause and inspection method of inverter overload tripping - LS power generation The cause and inspection method of inverter overload tripping - LS power generation

1. The main reason for the overload of the inverter (1) Malfunction, the current detection part inside the inverter has a problem, and the detected current signal is too large, resulting in tripping. (2) The mechanical load is overloaded, and the main feature of the overload is that the motor heats up, and it can be ...

Common faults in terminal blocks - LS generates electricity Common faults in terminal blocks - LS generates electricity

From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common types of faults in terminal blocks: ...

What are the components of the PLC? What are the components of the PLC?

The basic components of PLC for power production: 1. Memory   ​   The memory that registers the architecture software is called the architecture program memory. The memory that registers the application software is called the user program memory. 2. Power supply ...

LS power converter interference phenomenon LS power converter interference phenomenon

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. Use the inverter to control the water supply, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

The cause of motor burnout caused by the inverter - electricity production The cause of motor burnout caused by the inverter - electricity production

In fact, the fault of the motor is not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly in the following situations: 1. Treat the general motor as a ...

Fault analysis of servo motors – LS power generation Fault analysis of servo motors – LS power generation

1. Problem phenomenon: servo error OL, servo motor can not start, and there is abnormal sound problem analysis and possible causes: (1) Bearing damage, foreign objects falling and stuck, stator magnet bursting and falling or moving tissue jamming caused by the motor itself. (2) ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top