Delixi molded case circuit breaker Icu=ICS understands

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi 3P air switch, rated current 630A, rated voltage 380V. The Icu=Ics=70kA of this circuit breaker. When the short-circuit current reaches 70kA, can the circuit breaker still be used? If it works, the ICU is already at its limit, which is a contradiction. If it can't be used, ICS is 70KA, which means it can be used. Is there any resistance? Why Ics=Icu?

                              Delixi molded case circuit breaker Icu=ICS understands

In fact, the IEC introduced the ICS and ICU specifications, which are the result of the concession of the NEMA code and the VDE code in the United States. The United States NEMA chose the target of a similar ICU specification, while the Germany VDE chose ICS to measure the short-circuit function, so there was controversy. Eventually, both goals were written into the norm in 1987.

This can cause problems down the road. For these two goals, manufacturers need to prepare more samples, which is a waste of money and energy. In fact, in terms of design margins, ICS is more solid. In fact, many short circuit tests have been done, and there is verification after the test. Customers are also more willing to bear this goal. At this time, some industry leaders began to align these two goals, setting Ics = 100% Icu. Gradually, this goal became a symbol of the technical content of the circuit breaker, and gradually we took it.

Of course, the ICS was not high at the beginning, and the national standard did not die. You can reach the minimum specification, but it's not the same thing whether the customer chooses you or not. However, with the development of new technologies and new data, various manufacturers are exploring various key points of arc extinguishing in imitation and experiments, and the development of silver point and blowing data is relatively agile. We have also gradually achieved ICS=100% Icu, and many domestic manufacturers have reached this goal.

More on that
The scope of use of Delixi universal inverter The scope of use of Delixi universal inverter

A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor according to the needs and achieve higher production efficiency and energy savings. The general-purpose inverter has a wide range of application scales and can be used for various types of motors, including communication motors, direct motors, ...

How about Delixi switch? How about Delixi switch?

Delixi focuses on the development of green energy-saving industry, the construction of LED ecological industrial chain. It has established an industrial development format with Shanghai as the research and development center and Hangzhou and Jiaxing as the production base of LED lighting products, specializing in the development, production and sales of LED fluorescent lamps, three-proof lamps, downlights, spotlights, street lamps and other high-tech products.

Delixi frequency converter E series precautions Delixi frequency converter E series precautions

1. Before the inverter device is in place and debugged, please tighten the components, especially the connecting bolts of the wire part, if not tightened, the connection will be heated and cause fire. 2. The on-site planning of the installation should be reasonable, and the excellent ventilation environment should be maintained. 3. The incoming and outgoing power lines of the inverter are not ...

What are the advantages of Delixi inverter What are the advantages of Delixi inverter

(1) Optimize electrical equipment: when the motor is started, there is no large current impact, and the load of the transformer is reduced. (2) The energy-saving effect is obvious: it can reach 20%-45%. (3) Extend the life of the whole machine: it has the function of soft start, reducing the load ...

Delixi circuit breaker left zero right fire meaning Delixi circuit breaker left zero right fire meaning

The so-called "left zero and right fire of the circuit breaker" is nothing more than the order of the sockets - when facing the socket, the socket on the left is the neutral line, the socket on the right is the front, and that's it. Delixi socket wiring may not be "left zero right fire". ...

Delixi general inverter E100 series products introduction Delixi general inverter E100 series products introduction

E100 series products are a standard inverter with optimized open-loop vector control, V/F control, stable performance, rich functions, optimized structural design, exquisite appearance, and high cost performance. Technical features: ...

Inverter application skills - Delixi Inverter application skills - Delixi

1. Shielded wires should be used for signal lines and control lines, which is beneficial to avoid disturbance. When the line is long, for example the distance jumps 100m, the conductor cross-section should be enlarged. The signal line and the control line should not be placed in the same cable trench or tray with the power line, so as not to disturb each other, it is best to place it through the pipe, ...

Delixi three-phase motor electrical control circuit principle Delixi three-phase motor electrical control circuit principle

What is the principle of the electrical control circuit of the three-phase motor? First of all, let's take a look at what is the principle of electrical control of work machinery. The schematic diagram of the electrical control circuit of the working machinery is actually connected with graphic symbols, text symbols and lines to show the connection relationship and circuit of each electrical component.

Instrumentation overhaul method - Delixi Instrumentation overhaul method - Delixi

Contrasting method The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.

Hu Chengzhong, director of Delixi, suggested five major suggestions to optimize science and technology to benefit people's livelihood Hu Chengzhong, director of Delixi, suggested five major suggestions to optimize science and technology to benefit people's livelihood

Founded in 1984, Delixi Group started with thermal relays, 36 years of big waves, has been in the first camp of China's electrical industry for many years, and has been ranked among the top 500 Chinese enterprises for 18 consecutive years. In recent years, under the guidance of the strategy of "manufacturing power", Delixi has focused on the main line of high-end manufacturing, and has taken multiple measures to ...

Low dropout linear regulator design power supply precautions - Delixi Low dropout linear regulator design power supply precautions - Delixi

1. Pay attention to the maximum value of output current: this is a very critical parameter, the current used exceeds the maximum output current of LDO, then the voltage is unstable, and the system will fail. LDO limit parameters: The output current is considered according to the 2/3 criterion. The cost of the whole system ...

Precautions for instrument maintenance - Delixi Precautions for instrument maintenance - Delixi

1. When using a multimeter ohm, remember not to measure with electricity. 2. When using the logic pen and oscilloscope to detect the signal, it is necessary to pay attention not to make the probe contact the two measurement pins together, because the essence of this situation is to constitute a short circuit in the case of power-on. 3. Detect filtering in the power supply ...

Whether the inverter can be debugged without load - Delixi Whether the inverter can be debugged without load - Delixi

1. First carry out the no-load test operation of the inverter First of all, check whether all the wiring of the inverter is correct, do not connect the output of the inverter to the motor, and conduct a no-load test on the inverter first. Read the user manual of the inverter carefully before powering on to understand the relevant functions and settings, and operate ...

Analysis of common problems of inverter - Delixi Analysis of common problems of inverter - Delixi

1. Why does the maintenance function of the inverter operate when the clutch is connected to the load? When the load is connected with a clutch, at the moment of connection, the motor changes sharply from the no-load condition to the area with a large slip rate, and the large current flowing through causes the inverter to trip over the current and cannot work. ...

The reason for the heat and heat of the switch socket in Delixi The reason for the heat and heat of the switch socket in Delixi

1. The socket quality is low quality First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...

Problems in the installation and use of Delixi voltage regulator Problems in the installation and use of Delixi voltage regulator

What is the voltage regulator can not be connected in parallel, the voltage regulator is not open for a long time, what will be the problem with the voltage regulator still open under normal voltage, is it said that the voltage regulator and the undervoltage lamp is not lit to clarify that the voltage regulator is normal? Will a normally open regulator burn it out at normal voltage? ...

Frequently asked questions about Delixi voltage regulators Frequently asked questions about Delixi voltage regulators

Delixi voltage regulator will have a stable preset amplitude of a fixed output voltage, regardless of its input voltage or load conditions change. There are two types of voltage regulators: linear and switched The linear regulator is an active (BJT or MOSFET) operated by a high-gain differential amplifier ...

Delixi contactor selection considerations Delixi contactor selection considerations

Electrical safety is not a trivial matter in modern society. Delixi communication contactors are used in homes, public places or commercial buildings. As a power device, its importance is self-evident. If you buy an unsuitable communication contactor, it will appear briefly in the future application process ...

Delixi DZ47S wiring method Delixi DZ47S wiring method

The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same. Delixi DZ47LE C40 ...

Product features of Delixi equalizer Product features of Delixi equalizer

1. The divider is the sixth generation of intelligent machine using microcomputer chips, and the intelligent program is very high. 2. Single-phase three-phase connection, the divider on the market is scored as A, B, and C three-phase wiring for three-phase electricity, which is not only inconvenient for installation, but also prone to phase sequence errors. 3. Can ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top