Delixi general inverter E100 series products introduction

Create Date: 2024-8-30 12:03:23|Source: Delixi

E100 series products are a standard inverter with optimized open-loop vector control, V/F control, stable performance, rich functions, optimized structural design, exquisite appearance, and high cost performance.

                               Delixi general inverter E100 series products introduction

Technical features:

1. Exquisite shape and structure

Adopting the optimized shape structure, beautiful and atmospheric, the slide installation and the hole installation are compatible, and it is easy to use.

2. Adopt small integrated module, high reliability

The selection of miniaturized integrated modules with stable quality ensures product quality and performance, and at the same time improves cost performance.

3. Integrated communication module

Standard built-in RS-485 communication module, can achieve standard MODBUS-RTU communication, a host computer can communicate with multiple inverters at the same time, fast speed, good anti-interference effect.

4. Flexible selection

115KW and below standard built-in braking unit, 18.5-110KW optional built-in braking unit. 11-15KW standard built-in DC reactor, 18.5-22KW optional built-in DC reactance

device, 30-185KW optional external DC electrical appliances, 200-630KW standard built-in DC reactor.

Applications:

It is mainly used in occasions where there are certain requirements for input and output functions and no closed-loop vector control is required. Engraving machinery, textile machinery, glass machinery, printing and dyeing machinery, etc.

Options:

Pull-out keyboard, pull-out extension cable.

More on that
Delixi control transformer structure type Delixi control transformer structure type

Delixi's control transformer is one of the products used in many equipment, the type of Delixi transformer is divided into: BK, JBK, BKC, JMB, BJZ, DG, BZ and other series of control lighting transformers, with excellent performance, reliable work, wide applicability and other characteristics, generally used in machine tools, mechanical ...

Delixi AC contactor fault causes and solutions Delixi AC contactor fault causes and solutions

First, the iron core may not be able to suction power Causes: The power supply voltage is too low or fluctuates too much, the power supply capacity of the operating circuit is lacking or the wire is broken and the control contact is poor, the technical parameters of the coil are inconsistent with the application conditions, and the product itself is damaged. Solution: Turn up the power ...

Delixi inverter load type Delixi inverter load type

The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...

Precautions for instrument maintenance - Delixi Precautions for instrument maintenance - Delixi

1. When using a multimeter ohm, remember not to measure with electricity. 2. When using the logic pen and oscilloscope to detect the signal, it is necessary to pay attention not to make the probe contact the two measurement pins together, because the essence of this situation is to constitute a short circuit in the case of power-on. 3. Detect filtering in the power supply ...

Delixi brought EasyPro series solutions to the fair Delixi brought EasyPro series solutions to the fair

Shanghai, September 19, 2018 ---- Today, the 20th China International Industry Fair (hereinafter referred to as the "Industry Fair") officially kicked off in Shanghai. From the perspective of a new breakthrough in the integration of manufacturing and the Internet, this year's industry fair focused on showing the scientific and technological innovation of China's manufacturing profession.

The reason for the whitening of the copper bar installed on the Delixi plastic case circuit breaker The reason for the whitening of the copper bar installed on the Delixi plastic case circuit breaker

In the project, because of the 630 A circuit breaker wiring bar in the 500 kVA box-type transformer, see the second circuit breaker and circuit breaker on the left in the figure. The temperature of this corresponding region is significantly higher than that of the other two corresponding regions, and the other two phases are also hot, and the copper bars of this phase have turned white. There is no induction Deli ...

Delixi inverter harmonic control method principle analysis Delixi inverter harmonic control method principle analysis

1. Install AC reactor and DC reactor. When the inverter is used in the distribution transformer capacity is greater than 500kva, and the transformer capacity is greater than 10 times of the inverter capacity, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...

Precautions for the use of Delixi stabilized power supply Precautions for the use of Delixi stabilized power supply

1. The use environment of regulated power supply requires good ventilation, no moisture, no corrosive gas, explosive substances, conductive dust Egypt steam, etc., and it is required to be installed in places without intense oscillation. ​ 2. The voltage regulator is used according to the function of the electrical equipment.

Introduction of four-quadrant regulator - Delixi Introduction of four-quadrant regulator - Delixi

A four-quadrant power supply is a power supply capable of absorbing and supplying positive and negative currents and voltages. While a simple voltage converter is capable of generating a fixed output voltage from the input voltage, this feature is not sufficient in some applications. An example is the control of voltage nodes connected to capacitors that ...

Installation steps of motor protector - Delixi Installation steps of motor protector - Delixi

1. According to the requirements of the device part and the needs of the maintenance function, reasonably select the motor maintainer model and its various maintenance action parameter settings; 2. According to the requirements of the product operation manual, the correct device should be connected correctly according to the use of each terminal, and the operating power supply should be connected to the control ...

Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Delixi parameter voltage regulator performance and advantages Delixi parameter voltage regulator performance and advantages

1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with an inverter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is under voltage of the DC bus. Because the power supply of the control loop of this type of inverter is not taken from the DC bus, but from the AC input through the transformer alone.

Whether the inverter can be debugged without load - Delixi Whether the inverter can be debugged without load - Delixi

1. First carry out the no-load test operation of the inverter First of all, check whether all the wiring of the inverter is correct, do not connect the output of the inverter to the motor, and conduct a no-load test on the inverter first. Read the user manual of the inverter carefully before powering on to understand the relevant functions and settings, and operate ...

Fault analysis of commonly used voltage electrical appliances - Delixi Fault analysis of commonly used voltage electrical appliances - Delixi

1. Voltage circuit breaker problem The contact is overheated, you can smell the power distribution control cabinet, by checking that the moving contact is not completely inserted into the static contact, and the contact pressure is not enough, resulting in a decrease in the switching capacity, causing the contact to overheat. At this moment, it is necessary to adjust the operating organization so that the moving contact is completely inserted into the static contact ...

LDO low dropout linear regulator features - Delixi LDO low dropout linear regulator features - Delixi

Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...

The change of frequency conversion control mode - Delixi inverter The change of frequency conversion control mode - Delixi inverter

In the process of practical speed regulation, an ordinary frequency-adjustable communication power supply can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the effective use of the motor magnetic field, the suppression of the starting current and the acquisition of the desired torque characteristics, such as low-frequency torque characteristics.

Precautions for the use of Delixi leakage protector Precautions for the use of Delixi leakage protector

1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the working current balance in the zero sequence current transformer and causes the leakage protector to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.

Voltage regulator power selection and determination - Delixi Voltage regulator power selection and determination - Delixi

1. The output power of the voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.

Delixi circuit breaker insulation accident Delixi circuit breaker insulation accident

The circuit breaker insulation incident can be divided into the internal insulation terminal and the external insulation incident. The hazards caused by internal insulation incidents are generally greater than those of external insulation. (1) Internal insulation incidents The internal insulation end is mainly a bushing and a current transformer ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top