Contrasting method

The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires considerable knowledge and skill on the part of the maintenance personnel.

Two meters of the same model are required, and one of them is in normal operation. It is also necessary to have the necessary equipment to use this method, such as a multimeter, oscilloscope, etc. According to the nature of the comparison, there are voltage comparison, waveform comparison, static impedance comparison, output result comparison, current comparison, etc.

                                     Instrumentation overhaul method - Delixi

Capacitor bypass method

When a certain circuit produces a strange phenomenon, such as a chaotic display, the capacitive bypass method can be used to determine the part of the circuit that is likely to be faulty.

Segregation Law

The fault isolation method does not require comparison of the same model of equipment or spare parts, and is safe and reliable. According to the fault detection flow chart, the segmentation and enveloping gradually narrows the scope of fault search, and then cooperates with signal comparison, component exchange and other methods, and the fault will generally be found quickly.

Percussion

It is common to encounter the phenomenon that the instrument is running well and badly, and most of this phenomenon is caused by poor contact or virtual soldering. In this case, percussion and hand pressure can be used.

State adjustment method

Generally speaking, before the fault is determined, do not touch the components in the circuit, especially adjustable devices, such as potentiometers. However, if the paperless recorder takes a cross-reference measure in advance (e.g., marking the position or measuring the voltage or resistance value before it is touched), it is still allowed to be touched if necessary. Maybe after the change, sometimes the fault will be eliminated.

IC power supply and ground terminal; The transistor circuit is crossed at the base input or collector output to observe the effect on the fault phenomenon. If the capacitive bypass input of the color paperless recorder is invalid and the fault disappears when the output is bypassed, the fault is determined to be in this stage of the circuit.

More on that
Frequently asked questions about Delixi voltage regulators Frequently asked questions about Delixi voltage regulators

Delixi voltage regulator will have a stable preset amplitude of a fixed output voltage, regardless of its input voltage or load conditions change. There are two types of voltage regulators: linear and switched The linear regulator is an active (BJT or MOSFET) operated by a high-gain differential amplifier ...

Delixi surge protector knowledge quiz Delixi surge protector knowledge quiz

Many people don't know what a surge is, surge is also known as a surge or lightning protection maintainer, the first is to maintain the household electrical equipment when it rains and thunders to avoid being damaged by lightning, and when the lightning strikes high-voltage electricity is drained to the ground through the surge maintainer, it will not directly hit the electrical equipment ...

Delixi CDI-EM60 series inverter Delixi CDI-EM60 series inverter

Delixi CDI-EM60 series inverter is a high-performance inverter, with the following characteristics and use: Characteristic: 1. It has good stability and reliability to ensure the stability and safety of the system operation. 2. High degree, wide range of speed control, ...

Delixi won the lawsuit "Delixi United" to defend its rights by legal means Delixi won the lawsuit "Delixi United" to defend its rights by legal means

  On July 14, the official Weibo of the Beijing Municipal Patent People's Court "Intellectual Property Beijing" released information that Delixi Group Co., Ltd. (hereinafter referred to as "Delixi Group") sued the former administrative department of China's State Administration for Industry and Commerce to dispute the proposal has been adjudicated in the first instance not long ago, and the appellant Delixi ...

A brief introduction to the characteristics of Delixi A brief introduction to the characteristics of Delixi

1. Nominal value A suitable approximation of a switchgear or component and equipment to mark or identify it. 2. Limiting value The maximum or minimum promise of a quantity in the specification and specification. 3、 ...

Why is the operation of the inverter energy-efficient? - Delixi Why is the operation of the inverter energy-efficient? - Delixi

The inverter lowers the output frequency to reduce the speed of the motor, taking the conditioning air volume as an example. By reducing the air volume, power consumption can be significantly reduced. Why is the operation of the inverter energy-efficient? According to fluid mechanics, power = pressure× flow, flow ...

Delixi circuit breaker model difference Delixi circuit breaker model difference

CDB1 miniature circuit breaker is a kind of current-limiting high-breaking miniature circuit breaker with double protection of overload and short circuit, which is suitable for AC 50Hz, rated voltage 400V and below, rated current 63A and below circuits, as line overload and short circuit protection, can also be used under normal circumstances.

Delixi inverter harmonic control method principle analysis Delixi inverter harmonic control method principle analysis

1. Install AC reactor and DC reactor. When the inverter is used in the distribution transformer capacity is greater than 500kva, and the transformer capacity is greater than 10 times of the inverter capacity, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...

Delixi leakage protector protection Delixi leakage protector protection

1. Under what circumstances does the leakage maintainer not maintain the electric shock? The leakage switch models commonly used in general families are 1P+N and 2P, as far as the leakage maintainer of 1P+N and the leakage maintainer of 2P (single-phase electricity maintenance) are concerned, when people touch the zero line and the front together, people are touched.

Delixi inverter load type and selection points Delixi inverter load type and selection points

The correct selection of the inverter is very important for the normal operation of the control system. When selecting an inverter, it is necessary to have a thorough understanding of the load characteristics driven by the inverter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan and pump load. ...

Precautions for instrument maintenance - Delixi Precautions for instrument maintenance - Delixi

1. When using a multimeter ohm, remember not to measure with electricity. 2. When using the logic pen and oscilloscope to detect the signal, it is necessary to pay attention not to make the probe contact the two measurement pins together, because the essence of this situation is to constitute a short circuit in the case of power-on. 3. Detect filtering in the power supply ...

Delixi brought EasyPro series solutions to the fair Delixi brought EasyPro series solutions to the fair

Shanghai, September 19, 2018 ---- Today, the 20th China International Industry Fair (hereinafter referred to as the "Industry Fair") officially kicked off in Shanghai. From the perspective of a new breakthrough in the integration of manufacturing and the Internet, this year's industry fair focused on showing the scientific and technological innovation of China's manufacturing profession.

Problems affecting the normal operation of the inverter - Delixi Problems affecting the normal operation of the inverter - Delixi

  Seriously affect the normal operation of the inverter. The core components of the inverter are IGBT power semiconductor switching components. When they are working properly, they generate a lot of heat. If there is no fan forced cooling, the sensing head will immediately detect (IGBT) overheating (IGBT) and send it ...

Delixi bearing rust causes Delixi bearing rust causes

1. The instantaneous high temperature in the grinding process will make the surface of the workpiece reach a molten state, and the steel surface will react with the oxygen in the air chemically, which will form a very thin (20-30nm) iron oxide film.

Using a soft starter to misconception - Delixi Using a soft starter to misconception - Delixi

In the use of soft starters, some users often have some faulty concepts such as: 1. It is thought that whether the motor can start successfully is related to the function of the soft starter, and a good brand or even a foreign brand should be selected under heavy load. 2. When the motor is not ...

Delixi Electric CDW3 universal circuit breaker introduction Delixi Electric CDW3 universal circuit breaker introduction

The CDW3 series frame circuit breakers are rated from 400A to 6300A and 415V/690V AC for extreme environmental conditions of 50 Hz AC and -40°C to 70°C. It is mainly used in the distribution network, distributing electric energy, protecting lines and power supply equipment from ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with an inverter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is under voltage of the DC bus. Because the power supply of the control loop of this type of inverter is not taken from the DC bus, but from the AC input through the transformer alone.

The reason why the switch socket is hot - Delixi The reason why the switch socket is hot - Delixi

1. The socket quality is low quality First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...

The principle and operation method of Delixi inverter operation The principle and operation method of Delixi inverter operation

  The principle and operation method of Delixi inverter: 1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Pass the power input terminal of the inverter through the leakage maintenance switch.

Delixi three-phase transformer introduction Delixi three-phase transformer introduction

All large AC power blocks are transmitted and distributed at high voltage levels via a three-phase transformer. Single-phase transformers can be electrically connected to form a three-phase transformer bank in a distribution system. But the standard is to combine a single phase coil into a three-phase transformer unit on a common core ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top