The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same.
Delixi DZ47LE C40 air switch letters and numbers represent the meaning of the following:
DZ: Plastic case type circuit breaker
47: Planning code
LE: Function code (electronic residual current operated circuit breaker)
C40: Rated current is 40 amps
Working conditions for normal use
a. The altitude does not exceed 2000m
b. The ambient air temperature is not higher than +40°C and not lower than -5°C, and the average value of 24h does not exceed +35°C
c. When the maximum temperature is +40 °C, the relative humidity of the air does not exceed 50%, and a higher relative humidity can be allowed at a lower temperature, such as 90% at 20 °C.
d. In the medium without explosion risk, and there is no gas and dust in the medium that is sufficient to corrode the metal and destroy the insulation;
e. In a local area where there is no rain or snow;
f. No significant sway and shock vibration in the locality.
|
More on that
|
Delixi inverter application case
The traditional textile printing and dyeing industry is a labor-intensive industry, and the degree of automation is not high. Most of the transmissions used are not speed regulation, and most of the occasions that need speed regulation are DC motors, such as warping machines, sizing machines and many printing and dyeing equipment.
|
|
Delixi voltage regulator fault phenomenon
Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis
1. The contact pressure between the carbon brush and the coil plane is too small
2. The carbon brush is severely worn
Delixi voltage regulator has ...
|
|
Fault analysis of commonly used voltage electrical appliances - Delixi
1. Voltage circuit breaker problem
The contact is overheated, you can smell the power distribution control cabinet, by checking that the moving contact is not completely inserted into the static contact, and the contact pressure is not enough, resulting in a decrease in the switching capacity, causing the contact to overheat. At this moment, it is necessary to adjust the operating organization so that the moving contact is completely inserted into the static contact ...
|
|
Delixi three-phase motor electrical control circuit principle
What is the principle of the electrical control circuit of the three-phase motor? First of all, let's take a look at what is the principle of electrical control of work machinery. The schematic diagram of the electrical control circuit of the working machinery is actually connected with graphic symbols, text symbols and lines to show the connection relationship and circuit of each electrical component.
|
|
Delixi contactor selection considerations
Electrical safety is not a trivial matter in modern society. Delixi communication contactors are used in homes, public places or commercial buildings. As a power device, its importance is self-evident. If you buy an unsuitable communication contactor, it will appear briefly in the future application process ...
|
|
Delixi indicator light failure and solutions
1. What should I do if the indicator light is on and when it is dark
Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire. ...
|
|
Delixi E180 universal inverter introduction
Product Introduction
With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...
|
|
The five provinces of the "Strong Foundation Plan" take the lead in building a win-win ecology
Channel business is the foundation of Delixi electric business. Only by clearing the source and stabilizing the foundation can we flourish and build an evergreen foundation! Continuously improving and deepening the order management of shopping malls is the central strategic direction for the company to achieve continuous, healthy and high-speed development together with its distribution partners. For the maintenance of ...
|
|
Delixi low-voltage AC contactor can not be suction reason
AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...
|
|
Delixi CDRA soft starter features
Delixi CDRA soft engine is a set of soft start, soft stop, light load, energy saving and multi-functional protection in one of the motor control equipment. This is a shock-free and smooth motor during the entire start-up process. According to the type, it can be divided into equipment type and comprehensive.
...
|
|
Delixi voltage regulator in the case of no load stable work?
Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...
|
|
What are the advantages and disadvantages of dry and oil regulators? - Delixi
Oil Regulator: Also known as non-contact inductive regulator or intelligent non-contact regulator (only the name of the company's own selling point).
Forte:
1. No contact, no protection, impact resistance (especially instantaneous impact, 2 times of normal.) The reason for this is the slow response, which ...
|
|
Delixi intelligent switch and its advantages introduction
Delixi is one of the world's top 500 enterprises, the quality of its switches is excellent, the layout is reasonable, and is deeply liked by the majority of customers. Founded in 1984, China Delixi Holding Group Co., Ltd. is a large-scale group integrating capital operation, brand operation and industrial operation, with a registered capital of 15 ...
|
|
Damage and repair of internal electronic components of the inverter - Delixi
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter).
Middle...
|
|
The difference between air switch and leakage protection switch - Delixi
(1) The function is different.
An air switch is a kind of circuit breaker that maintains "something", which can maintain the safety of the entire household wiring and appliances, and avoid the overheating and burning of the wires.
The leakage maintenance switch is a kind of circuit breaker for maintenance personnel, which can block the circuit in time when leakage is carried out to avoid the danger of electric shock.
|
|
Delixi integrated voltage regulator knowledge
The role of a voltage regulator is to convert an unstable DC voltage into a stable DC voltage. The integrated voltage regulator has a wider and wider range of applications due to its advantages such as small size, good voltage regulation performance and perfect maintenance function. There are two types of integrated voltage regulators: linear power supply regulators and switching power supply regulators.
|
|
CDQ1F series PC-level excitation automatic transfer switch - Delixi
Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places!
CDQ1F Active ...
|
|
Delixi time control switch KGL1 latitude and longitude technical parameters
Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...
|
|
Delixi linear and switching regulators introduced
01. What is a linear voltage regulator?
A linear regulator uses a transistor or FET operating in its linear region to subtract the excess voltage from the input voltage of the application to produce a conditioned output voltage.
The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...
|
|
Delixi inverter speed parameters
There are two speeds of Delixi inverter, one is the target speed, and the other is the speed of practice.
The target speed requires the value of the detailed parameters to be adjusted, such as the *** high frequency/*** high frequency in the inverter parameters; Regarding the practical output speed, the frequency needs to be checked in the inverter parameters ...
|
|