1. Why does the maintenance function of the inverter operate when the clutch is connected to the load?

When the load is connected with a clutch, at the moment of connection, the motor changes sharply from the no-load condition to the area with a large slip rate, and the large current flowing through causes the inverter to trip over the current and cannot work.

                              Analysis of common problems of inverter - Delixi

2. Why is the inverter stopped when the large motor is running together in the same factory?

When the motor starts, the starting current corresponding to the flow rate and capacity, the transformer on the stator side of the motor produces a voltage drop, and when the motor capacity is large, the voltage drop is also large, and the inverter connected to the same transformer will make the judgment of undervoltage or instantaneous stop, so sometimes the maintenance function (IPE) action will form a stop operation.

3. What is Frequency Conversion Resolution? What's the point?

In the case of digitally controlled frequency converters, the output frequency is given in stages, even if the frequency command is an analog signal. The smallest unit of this gradient is called the variable resolution. The frequency conversion resolution is generally 0.015-0.5Hz. For example, if the resolution is 0.5Hz, then the top of 23Hz can be changed to 23.5 and 24.0Hz.

4. Is it possible to put the motor directly into a fixed frequency inverter without using soft start?

It is possible at very low frequencies, but if the given frequency is high, the same power supply is near the condition of direct starting. The large starting current (6-7 times the rated current) will flow excessively, because the inverter blocks the overcurrent, and the motor cannot start.

5. What problems should be paid attention to when the motor works beyond 60Hz?

When working above 60Hz, the following precautions should be taken:

(1) Machinery and equipment should have sufficient potential to work at this speed (mechanical strength, noise, vibration, etc.).

(2) When the motor enters the constant power output scale, its output torque must be able to maintain the work (the output power of the shaft such as the fan and pump increases proportionally to the cube of the speed, so it is necessary to pay attention to the speed when the speed increases slightly).

(3) The life of the bearing should be fully considered.

For medium-capacity motors, especially 2-pole motors, it is necessary to consult carefully with the manufacturer when working above 60Hz.

6. Can the inverter drive the gear motor?

According to the structure and smoothing method of the reducer, there are several problems that need to be paid attention to. In the structure of the gear, 70-80Hz can generally be considered as the maximum limit, and when the oil is smooth, it is related to the damage of the gear when the oil is smooth, and the continuous work at low speed is related to the damage of the gear.

7. Can the inverter be used to drive a single-phase motor? Is it possible to use a single-phase power supply?

Single-phase motors are basically unusable. In the case of a single-phase motor with governor switch starting, the auxiliary windings will be burned out at the speed regulation scale below the operating point; Regarding the capacitor starting or capacitor working method, the capacitor will be induced to burst. The power supply of the inverter is generally 3 phases, but there are also models that operate with a single-phase power supply for small capacitances.

8. How much power does the inverter consume?

It is related to the type, working condition, and frequency of use of the inverter, but it is difficult to answer. However, the power of the inverter below 60 Hz is about 94%-96%, and the loss can be calculated based on this, but the built-in regenerative braking (FR-K) inverter will increase the power consumption if the loss during braking is also taken into account, so it is necessary to pay attention to the design of the operation panel.

9. Why can't it be used in the whole area of 6-60Hz?

Generally, the motor uses the outer fan installed on the shaft or the blades on the rotor end ring for cooling, and if the speed drops, the cooling effect decreases, so it cannot accept the same heat as high-speed work, and the load torque must be reduced at low speed, or the combination of a large-capacity inverter and the motor, or the use of a special motor.

10. What should I pay attention to when using a motor with a brake?

The power supply of the brake excitation circuit should be taken from the input side of the inverter. If the brake actuates while the inverter is outputting power, an overcurrent block will be formed. Therefore, it is necessary to stop the output of the inverter before activating the brake.

More on that
Delixi circuit breaker product characteristics classification Delixi circuit breaker product characteristics classification

The function of Delixi circuit breaker is to make the circuit breaker internal electromagnetic tripping when the electrical equipment produces short circuit, overload, etc., resulting in the circuit breaker disconnecting the power supply, and maintaining the safety of electrical equipment and personnel. When the electrical equipment is running, the circuit may produce abnormalities, which is the demand circuit breaker in the ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Causes the inverter breakdown factor - Delixi Causes the inverter breakdown factor - Delixi

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the inverter voltage formed due to various reasons that exceeds the rated voltage, which is reflected in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

Delixi low-voltage inverter selection method Delixi low-voltage inverter selection method

The selection of inverter is indeed very important, because if the selection is not suitable, it will cause a waste of time and money, and at worst it will cause production incidents and personnel damage. First of all, according to the classification and selection of the inverter 1. Inverters can be divided into general-purpose inverters and special inverters. ...

CDQ1F series PC-level excitation automatic transfer switch - Delixi CDQ1F series PC-level excitation automatic transfer switch - Delixi

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

Delixi inverter selection points Delixi inverter selection points

Variable-frequency Drive (VFD) is an electric power control equipment that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the working power supply of the motor. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...

Circuit breaker control loop to reduce damage method - Delixi Circuit breaker control loop to reduce damage method - Delixi

1 Anatomy of the causes The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows: · When the personnel on duty operate, the precautions are not well grasped or the operation is improper; · The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...

Regularly inspect the inverter steps and methods - Delixi Regularly inspect the inverter steps and methods - Delixi

When the VFD is viewed regularly, the power supply should be blocked, the operation of the VFD should be stopped, and the cover of the VFD should be removed. The first thing is to check the places that cannot be seen without downtime, or the places where it is difficult to find problems on a daily basis, as well as the inspection and adjustment of electrical characteristics. After blocking the VFD power supply, the main power ...

Delixi inverter Delixi inverter

Delixi inverter has launched CDI9000 series inverter, CDI9100 series inverter, CDI9100-S series inverter, CDI9200-G series general-purpose inverter, CDI9200-P series fan pump inverter, CDI9200-ZS series injection molding machine special inverter, CDI9200-GS series ...

Delixi inverter function introduction Delixi inverter function introduction

1. If the impact on the power grid can be reduced, it will not cause the problem of excessive peak-to-valley difference. 2. It can speed up the controllable function, so as to speed up the smoothing according to the needs of users; 3. The abort method of the motor and equipment is controllable, so that ...

The reason for the unstable pressure of Delixi inverter system The reason for the unstable pressure of Delixi inverter system

Problem Description: The pressure of Delixi inverter system is unstable, simple vibration? Solution(s): The pressure of the system is unstable, which can be due to the following reasons: A. The position of the pressure sensor to collect the pressure of the system is ...

Delixi time control switch KGL1 latitude and longitude technical parameters Delixi time control switch KGL1 latitude and longitude technical parameters

Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...

Voltage regulator failure and solution - Delixi Voltage regulator failure and solution - Delixi

1. There is no output, no voltage indication or no start when the machine is turned on. Overvoltage or undervoltage maintenance 1. Adjust the internal output voltage adjustable potentiometer 2. The wrong phase and the lack of phase are maintained, and the two phases are arbitrarily replaced by three phases 3. The main control circuit board is broken 3. Replace 4. The output AC has been ...

Thermal calculation of linear regulator - Delixi Thermal calculation of linear regulator - Delixi

Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is the same as the power accounting, which is purely the value of the output input voltage difference multiplied by the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...

Delixi selection of wire points Delixi selection of wire points

When buying wires, the first thing to look at is two aspects: conductors and insulation. 1. Conductors 1. Color High-quality copper is called "red copper" or "red copper" - the color of this copper is red, purple, and purple-red. The worse the copper ...

Delixi product parameter unit VF and V difference Delixi product parameter unit VF and V difference

Voltage vf and v difference: The two have different meanings, vf on the battery represents the feedback voltage, while v represents the capacity of the battery, which is the unit of measurement of voltage. Lithium battery is a kind of battery with lithium metal or lithium alloy as the positive/negative electrode data and the use of non-aqueous electrolyte solution. ...

Introduction of molded case circuit breaker - Delixi Introduction of molded case circuit breaker - Delixi

Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...

Precautions for instrument maintenance - Delixi Precautions for instrument maintenance - Delixi

1. When using a multimeter ohm, remember not to measure with electricity. 2. When using the logic pen and oscilloscope to detect the signal, it is necessary to pay attention not to make the probe contact the two measurement pins together, because the essence of this situation is to constitute a short circuit in the case of power-on. 3. Detect filtering in the power supply ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top