First, the application environment of the weighing system

Sensors operating in high-temperature environments should use high-temperature resistant sensors, and especially harsh occasions must also be equipped with heat-insulation, water-cooled or air-cooled devices.

For use in alpine areas, load cells with heating devices should be considered.

Effects of dust, humidity and corrosiveness:

Stainless steel series products are suitable for environmental humidity > above 80%RH, and other acids and ammonia are corrosive;

Rubber seal series alloy steel products are suitable for ambient humidity <65%RH, no water infiltration, no other corrosive gases and liquids;

Welded series alloy steel products are suitable for environmental humidity <80%RH, drainage and circulation, no other corrosive gases and liquids;

Aluminum alloy series products are suitable for ambient humidity <65%RH, no water infiltration, no other corrosive gases and liquids.

In overhead weighing systems, safety and overload protection should be considered.

In flammable and explosive environments, it is necessary to choose explosion-proof sensors, and the sealed cover of explosion-proof sensors should not only consider its airtightness, but also consider the explosion-proof strength, as well as the waterproof, moisture-proof, explosion-proof and so on of the cable lead-out surface.

                              Choice of load cell construction form – ifm

Second, the scale structure characteristics of the requirements

1. The installation space of the carrier. In some places where the device has space constraints, space constraints should be considered when selecting load cells.

2. Convenient device protection. Regardless of the reliability of any equipment, it is necessary to consider the protection of the device. In addition to the convenience of the device, it is also necessary to consider whether the protection during operation is convenient and whether the sensor can be replaced quickly.

3. Effect of lateral forces. When selecting a sensor, it is necessary to consider whether there are lateral forces in the operation of this weighing scale. The ability of the load cell planned according to the shear stress principle to resist lateral force is relatively strong, and the ability of the load cell planned by the principle of normal stress to resist lateral force is relatively weak.

4. The stiffness of the carrier, the base structure and the accessories. The stiffness of these structures has a direct impact on the amount of deformation and thus the accuracy of the measurements.

5. The influence of temperature on the scale body. For outdoor weighing systems with long carriers and large areas, such as truck scales, large tanks, etc., it is necessary to consider the expansion coefficient of the carrier.

More on that
Notes on Linear Position Sensors – ifm Notes on Linear Position Sensors – ifm

1. If the electronic ruler has been used for a long time, and the seal is now aging, it is mixed with a lot of impurities, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers constantly beat. At this time it can be said that the electronics of the linear displacement sensor ...

The ifm identification system has an RFID antenna with IO-Link The ifm identification system has an RFID antenna with IO-Link

Sensitive parameterization, diagnostics and data processing of ifm sensors are suitable for many different uses9 versions, suitable for a variety of different types of sensitive parameterization, diagnostics and data processing with I/O-Link Ideal for the identification of small data volumes with LR DEVICE or IO-L ...

Select the appropriate mounting holes for ifm sensors Select the appropriate mounting holes for ifm sensors

ifm sensors have a lot of precautions at the time of installation, and it is necessary to pay attention to the orientation of the device, if the device orientation is not suitable, it will also form damage to the pressure sensor. ifm sensors are required to be checked at the time and time of the device.

Common faults of pressure sensors – ifm Common faults of pressure sensors – ifm

If the power supply is normal, it is necessary to carry out a simple pressurization to see if the output has changed, perhaps observe whether the zero position of the sensor has an output, assuming that it has not changed, the sensor has been damaged, otherwise it is the appearance of the damage or other links of the whole system. ...

Considerations for the selection of load cells – ifm Considerations for the selection of load cells – ifm

1. Sensor scale: (1) In normal use (static test or quasi-static test, the frequency of use is not high), the scale of the sensor should be selected to consider the force value of the measurement, but also to consider the weight of the auxiliary tool (test fixture) and so on.

Load cell wiring method – ifm Load cell wiring method – ifm

There are four-wire and six-wire load cells. Four-wire system: EXC EXC: Power cord, that is, the DC power supply supplied by the instrument to the sensor. SIG, SIG-: The signal line, that is, the signal line output by the sensor, is output to the instrument. In addition to the above four lines, there are more than two in the four-wire system: SEN, SEN-: feedback line ...

What are the typical designs of torque sensors – ifm What are the typical designs of torque sensors – ifm

Unlike load cells or force transducers, the measuring body of a torque transducer is not subjected to a tension load when used, but is torsionally affected by lever torque or torque. Therefore, torque sensors require special strain gauges to measure this type of load, i.e. torque. Canon...

Features of the S-type load cell – ifm Features of the S-type load cell – ifm

1. S-type load cells are moderately priced and suitable for mass production - good sensor consistency is required, suitable for automated batch production, and high requirements for processing equipment to eliminate inconsistencies and faults formed by manual operation. 2、 ...

Six-wire and four-wire wiring of load cells Six-wire and four-wire wiring of load cells

Because the load cell has the advantages of high measurement accuracy, good temperature characteristics, and stable operation, it is widely used in the dynamic and static measurement of various structures and the primary appearance of various electronic scales. The load cell can be selected with two different input and output wiring methods: one is ...

3-axis accelerometer – ifm 3-axis accelerometer – ifm

There are two types of accelerometers: one is the angular accelerometer, which is improved from the gyroscope. The other is a linear accelerometer. It can also be divided into single-axis, dual-axis and three-axis accelerometers according to the measurement axis. ...

How ifm sensors determine the exact installation location How ifm sensors determine the exact installation location

When installing an ifm sensor, the first thing to do is to confirm the orientation of the sensor and then to install it correctly. So how do we confirm the orientation of the sensor? The ifm sensor confirms the detailed orientation of the device ...

Structure and application of resistive sensors - ifm Structure and application of resistive sensors - ifm

Structure of a resistive sensor The structure of a resistive sensor consists of two basic parts: a resistive element and a brush (movable contact). The motion of the brushes in relation to the resistive elements can be linear, rotational and spiral, thus converting the linear or angular displacement into the necessary ...

Principle and characteristics of IFM capacitive sensors Principle and characteristics of IFM capacitive sensors

Capacitive sensors can detect any object without touch. In contrast to inductive sensors, which can only detect metals, capacitive sensors are also capable of detecting non-metallic materials. principle 1. The first thing to be measured is ...

How to use load cells and amplifiers – ifm How to use load cells and amplifiers – ifm

1. Wiring according to wiring requirements 2. Connect the specified size DC power supply to the transmitter. 3. Connect the sensor and adjust it to the corresponding zero output value (the corresponding zero output value (e.g. 0-10V output. ...

Precautions for the installation of ultrasonic level gauges Precautions for the installation of ultrasonic level gauges

1. The appearance is installed outdoors, and it is recommended to install a sunshade to prolong the service life of the appearance. 2. Wire and cable protection pipes should be sealed to avoid water accumulation. 3. Although the appearance itself is equipped with lightning protection equipment, when the appearance is used in the multi-lightning area, it is advocated to distinguish the inlet and outlet lines on the surface.

Measuring pre-work with vibration sensors – ifm Measuring pre-work with vibration sensors – ifm

1. Confirmation of the initial void The various types of oscillating sensors should have excellent linearity at a certain void voltage value, so it is necessary to adjust the appropriate initial void when installing the sensor. According to the characteristic curve of the oscillation sensor, the sensor used for oscillation measurement ...

Guangzhou Industrial Automation Technology and Equipment Exhibition ended successfully Guangzhou Industrial Automation Technology and Equipment Exhibition ended successfully

The Guangzhou International Industrial Automation Technology and Equipment Exhibition (SIAF) has successfully concluded on March 12, and the number of exhibitors has reached a record high, and we have also felt the enthusiasm of visitors for ifm's booth and products. ...

Understanding the accuracy of sensors – ifm Understanding the accuracy of sensors – ifm

There are three indicators of precision: precision, correctness, and precision, but how do you understand them? precision It sheds light on the sloppy nature of the measurement results. That is, for a certain stable target (to be measured) by the same measurer with the same sensor and measurement appearance in the appropriate ...

Grounding Considerations for Servo Drives – ifm Grounding Considerations for Servo Drives – ifm

1. The correct shield grounding point is at the reference potential inside the circuit, which depends on whether the noise source and receiver are grounded together, or may float. Second, it is necessary to ensure that the shield is grounded at the same point so that the ground power ...

Examples of applications for ifm inductive sensors in the industry Examples of applications for ifm inductive sensors in the industry

Spindle speed detection In order to prevent damage to wind turbines from overspeeding, the rotational speed is detected using inductive sensors and evaluated using safety-relevant speed monitors. The ifm IFS24X series of inductive sensors is equipped with M12 housing (IGS24X series with M18 housing), ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top