The advantage of busway over cable in modern construction - Wiener

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The power supply trunk of modern buildings plays a very important role like the aorta of the human body, and if something goes wrong, it can cause serious consequences. In the 80s of the 20th century, many stable cables were used in modern buildings. With the rapid development of cities, the power load of buildings has increased dramatically, and the limitations such as difficult to disconnect cables and small capacity have become more and more obvious. At this time, the busway with large capacity and convenient branches is widely used in various modern buildings, rather than cables, so let's learn about the advantages of busway compared to cables in modern buildings.

                                 The advantage of busway over cable in modern construction - Wiener

1. Large ampacity and low power loss

The large additional operating current of a single busway reaches 6300A, which can meet the power demand of the current large load. The large additional operating current of a single circuit cable is only 800 amps. The current carrying capacity of the busway can be stable and prevent unnecessary power loss. The cables are placed in sealed trays in such a way that unnecessary power loss is added.

2. The cooling conditions are good, and the temperature rise is low

The busway is a flat conductor, and the gross insulation material is also a thermal insulation material, which uses air to conduct heat and emit heat, and emits heat through the outer part of the metal shell. Compared with round conductor cables and pre-branched cables, busway has the characteristics of good heat dissipation and low impedance.

3. Foldable and convenient, adaptable

The busway makes it easy to separate, and when adding equipment, you only need to add a pin box nearby. When adding capacity, simply replace the protective device capacity inside the plug box. After disconnecting the prefabricated disconnect cable, the long parallel cable must be re-added between the distribution cabinet and the load, and the power supply must be blocked for normal operation. Faults can affect the safety of adjacent circuits.

Long service life and high safety function

The service life of the bus duct can be more than 30 years, and the operation is relatively safe. Because of the high short-term withstand current, it is possible to equip the plug box of the branch circuit with special protection devices such as fuses or circuit breaker protection, and there are fewer natural defects in the circuit. The life of the cable is barely more than 15 years, the line aging is simple and faulty, for each layer of tap protection, the distribution room must be controlled and protected separately.

The device is simple and the maintenance is less in the later stage.

The busway structure is small, occupies little space, and is composed of a special device bracket, which does not require additional support. In routine maintenance, it is only necessary to measure the temperature rise of the shell, new bolts, wire boxes, etc. After the fault, only the faulty plug box needs to be replaced, and the power transmission and distribution of other equipment will not be affected. It can be reused after differentiation. The cable placement structure is complex, the clear steamer needs to equip the cable tray, the underground routing needs to dig trenches, and the construction cost is high. After the fault occurs, the whole line should be stopped, the replacement cycle is long, and the loss is large.

6. Overload can be strong, and the constant temperature effect is good

The busway insulation data uses the data with an operating temperature of 100 or more. For example, busway products use DuPont polyester film with an insulation room temperature rating of 130 class B. Together, the busway shell is made of metal, which is simple to burn and has good fire resistance. As mentioned above, compared with the current carrying capacity, safety, service life, energy saving, and convenience of installation, the busway has more advantages than cables. It is believed that in the near future, in industrial factories, high-rise buildings, commercial complexes, rail transit, etc., the bus home will be more widely used in our lives, rather than cables.

More on that
Low-voltage cabinet for capacitance compensation – Wienal Low-voltage cabinet for capacitance compensation – Wienal

Capacitor compensation is indispensable in low-voltage cabinets, so what is the effect of capacitor compensation. The meaning of this is that it acts as a capacitor. Let's take a look at the principle of capacitor compensation first, when the capacitor is compensated, the capacitor and the load are connected in parallel, and the capacitor is like a bin. When the load increases, the power supply has internal resistance, so that ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this time, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a small size, so that when there is a problem with the bus, the bus tie circuit breaker can be quickly tripped, cut off...

Wiener plug-in busway features Wiener plug-in busway features

The plug-in busway has a high overload capacity The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105C is selected for the insulation material used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed ( ...

Phase of the busway in the low-voltage incoming line – Wiener Phase of the busway in the low-voltage incoming line – Wiener

According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.

220V DC Hazard in Busbar System – Wiener 220V DC Hazard in Busbar System – Wiener

The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.

The way in which the Wiener high-voltage busway is selected The way in which the Wiener high-voltage busway is selected

In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...

What are the specific accessories of the busway - Wiener What are the specific accessories of the busway - Wiener

1. Connecting copper plates, insulating plates, and insulating piercing screws generally refer to tension spring brackets, bus connectors, connecting copper bars, and plug-in boxes. The bracket is used for buffer busbars to squeeze each other during connection, and the adapter is used for connection. The connecting copper bar is the local use of the box and the bus connection of the cabinet connection. ...

The essence of Wiener busbar technology The essence of Wiener busbar technology

1. Closed busbar hooking technology Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.

Wiener bus adapter features: Wiener bus adapter features:

Functional aspects The bus bar is made of copper or aluminum, which has high current density, small resistance and small skin effect, and does not need to be used for capacity reduction. The small voltage drop also means that the energy loss is small, which ultimately saves the user's capital. As far as the cable is concerned, because the cable core is a multi-strand thin copper wire, its root surface ...

Advantages of installing cable trays with busway – Wiener Advantages of installing cable trays with busway – Wiener

When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows: 1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.

Venal common bus scheme applicable places and precautions Venal common bus scheme applicable places and precautions

When multiple inverters are used in the common DC bus, because the DC bus between the inverters is connected together, the bus energy between the inverter in the power generation operation state and the inverter in the electric operation state can flow to each other, so that the voltage of the common bus remains relatively stable, and the body ...

Wiener busbar system PT disconnection treatment Wiener busbar system PT disconnection treatment

The judgment of PT three-phase voltage loss (symmetrical disconnection) is fundamentally the same for each manufacturer, and it is judged according to the three-phase no voltage and the current of the line. The same is true for PT asymmetrical wire breakage. After analyzing the characteristics of PT wire breaking, the specific judgment of PT asymmetric wire breaking of different manufacturers ...

Structural characteristics of high-voltage busway - Vernal Structural characteristics of high-voltage busway - Vernal

If you understand the scope of application of the busway, you can see that the excellent effect of the busway has the upper hand, which has a lot to do with the structural features. Therefore, if you want to have more confidence with the bus duct, you still need to understand it from the structural characteristics. At a time when China's economy is developing rapidly, ...

What are the characteristics of the bus wiring method of the power system? What are the characteristics of the bus wiring method of the power system?

(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected. ...

Busbar system in detail – Vernal Busbar system in detail – Vernal

1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked. 2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm. 3. Strip NH-fuse type load barrier switch with scale 00 ...

Characteristics of power system bus wiring mode Characteristics of power system bus wiring mode

(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus. ...

Classification of the use of different places in the busway - Vernal Classification of the use of different places in the busway - Vernal

(1) General bus duct Non-flame retardant and non-fire-resistant bus duct used in general load power distribution. In the event of a fire during a short circuit, it will always incinerate to other connected busbars, which may briefly cause fire accidents. (2) Flame retardant bus duct ...

Precautions for the operation of low-voltage cabinets - Wienal Precautions for the operation of low-voltage cabinets - Wienal

1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings. 2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance. 3. On the secondary circuit of the voltage transformer in operation...

Difference Between Busbar and Cable – Vernal Difference Between Busbar and Cable – Vernal

When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage power distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. ...

Introduction to busbars, busway, and busbridges - Wiener Introduction to busbars, busway, and busbridges - Wiener

generatrix In the field of electricity, the busbar can also be called the busbar, busbar, etc., which mostly refers to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top