Mitsubishi MELSEC iQ-F makes IoT a simple one

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

The MELSEC iQ-F series of small PLCs completes the high-speed system bus, supports a variety of networks, enriches the built-in functions, and makes it more convenient to use. From stand-alone use to network-based system proposals, we strongly support the needs of customers for "cutting-edge products in the manufacturing industry". Using MELSEC iQ-F、I can do it briefly: I can communicate! I can store it! I can see it! I can teleport!

                                 Mitsubishi MELSEC iQ-F makes IoT a simple one

1. Able to communicate (only through the setting of a brief connection)

The built-in Ethernet function only needs to be briefly set up by GX Works3, and the communication with the PLC can be completed without a program. It supports various networks such as CC-Link IE TSN, CC-Link IE field network, CC-Link IE field network Basic, CC-Link V2, and AnyWireASLINK system.
  ​
With a simple setup, it can communicate not only with many PLCs such as Mitsubishi Electric's MELSEC iQ-R series, MELSEC Q series, MELSEC iQ-L series, MELSEC L series, MELSEC iQ-F series, and MELSEC FX3 series, but also with multi-brand PLCs.

2. Can be stored (abbreviated record)

The ability to store a variety of information on an SD card can be combined with functions such as data dumping, real-time supervision, and backup/recovery to further increase the value of data.

Information from computers and network devices can be saved to the SD memory card on a regular basis, and the values of the soft components of the CPU module at any point in time can also be saved to the SD memory card. By using the stored data, it is possible to efficiently analyze the operating conditions of the equipment and the causes of failures. At the same time, combined with the offline monitoring function, the recorded software component data is monitored and displayed on the program editor. If it is set to trigger when an error occurs, you can check the status of the error and help you investigate and investigate the cause. The collection result can be checked by GX Works3.

3. Be able to see (briefly complete the visualization)

The visualization is done briefly on a PC or tablet, and the CPU module can be monitored and diagnosed via a web browser on the PC. The built-in functions of the FX5U/FX5UC CPU module or GOT are used to complete machine collaboration, enabling field workers to share information with each other. In addition, remote locations such as offices can be used to monitor the safety of equipment by monitoring errors and collecting information through the network.

4. It can be transmitted (through the FTP function, it can transmit data to the computer)

Without going to the field, you can get data from a long distance. Able to handle data using the office computer, analyze production information, and reduce maintenance work.

The FTP server function allows you to remotely access recorded data without having to go to the site. Multiple documents can be processed through the office computer, which can reduce the handling and preservation work.

If you visit a web server through your computer's web browser, you will be able to supervise and diagnose the CPU module and understand the health of the device, even if you don't have a dedicated tool.

Fast, simple, and sensitive, the aspiring IoT application requires strong fundamental support. Mitsubishi Electric's MELSEC iQ-F continues to expand its product lineup to improve its ability to respond to application scenarios by improving its basic functions, connection with drive equipment, and improvement of the programming environment. Mitsubishi Electric will continue to improve product quality, upgrade product functions, and satisfy enterprises at different levels of intelligent production to meet their own production and promotion needs.
More on that
Power factors affecting Mitsubishi inverters Power factors affecting Mitsubishi inverters

The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements: 1) The frequency conversion speed regulation system has low loss and high operating power. 2) The motor is always kept running at a low slip rate, which reduces the rotor loss.

Mitsubishi Step Ladder Instruction [STL], [RET] usage example Mitsubishi Step Ladder Instruction [STL], [RET] usage example

Step Instruction (STL) is an instruction that uses internal software components to control the process step on top of the sequential control program. A step-to-back instruction (RET) is an instruction that is used to return to the main program (bus) after the state (S) process is completed. ...

Analysis of PLC and inverter connection problems - Mitsubishi Analysis of PLC and inverter connection problems - Mitsubishi

When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1. PLC switch command signal input Inverter input ...

Mitsubishi PLC programming cable communication port setting method Mitsubishi PLC programming cable communication port setting method

1. Plug the programming cable into the USB port of the computer. 2. On the desktop, place the mouse on the "My Computer" icon, and then right-click. 3. In the pop-up menu, select "Device Manager". ...

Mitsubishi PLC network structure Mitsubishi PLC network structure

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment and sensors and drive equipment, which is the low-level network of the entire network system. The CC-Link fieldbus connection is selected, and the number of wiring is greatly reduced, and the system maintainability is improved. Whereas...

Mitsubishi PLC control system electroplating production line design Mitsubishi PLC control system electroplating production line design

Planning PLC control system control requirements for electroplating production line: 1) SQ1-SQ4 is the driving advance and retreat limit switch, and SQ5-SQ6 is the upper and lower limit switches. 2) The workpiece is lifted to SQ5 to stop, and the car is driven to SQ1 to stop.

Mitsubishi inverter heat dissipation causes and countermeasures Mitsubishi inverter heat dissipation causes and countermeasures

1. Whether there is abnormal change in the sound during the operation of the equipment, including whether there is oscillation during the operation of the motor. 2. Whether the ambient temperature of the inverter installation is too high or too low, the working temperature is generally required to be in the range of -10°C - +40°C, and it is better to be about 25°C. ...

Mitsubishi PLC program lost backup program write method Mitsubishi PLC program lost backup program write method

The reasons for the loss of the PLC program are the lack of battery power supply for the user's saved program, the internal circuit of the PC, the motherboard burned out due to the impact of external high voltage such as lightning strikes, etc., which will be encountered in our PLC control system. For example, the old type of plc such as the FX2N series, which has been discontinued...

Mitsubishi Electric one-click adjustment user instruction mode tuning method Mitsubishi Electric one-click adjustment user instruction mode tuning method

1. Set PA08 to 0003 and set the gain adjustment form to; , the function is to prevent the failure of the active calculation of the inertia ratio, and the alarm C005 will be given. 2. Flip it over; menu; , set the speed/acceleration and deceleration/movement amount, according to the actual situation ...

PLC circuit debugging precautions - Mitsubishi PLC circuit debugging precautions - Mitsubishi

1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the state; The positive logic criterion is usually used, that is, when the input and output are live, it is in the "ON" state and the data value is "1"; Conversely, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...

Mitsubishi inverter capacity selection Mitsubishi inverter capacity selection

The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method. 1. When accelerating or operating at constant speed The efficiency of the inverter is the output current, that is, how much current the inverter can provide to the motor. Frequency converters ...

Features of the MELSEC iQ-R series of programmable controllers Features of the MELSEC iQ-R series of programmable controllers

1. Routine control is consistent with safety control In the MELSEC-QS series, it is necessary to prepare a system for conventional control and a system for safety control. With the MELSEC iQ-R series of safe programmable controllers, it is possible to combine conventional and safe control into a single system. Quiet...

The matching relationship between the inverter and the motor - Mitsubishi The matching relationship between the inverter and the motor - Mitsubishi

It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...

PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection ...

Mitsubishi FR-A700 series inverter problem Mitsubishi FR-A700 series inverter problem

1. Consultation question: FR-A700 series Mitsubishi inverter, the suffix is ending in -CA1, what kind of inverter? Solution: The suffix -CA1 is a special model with take-up control. 2. Consultation question: FR-A ...

Mitsubishi PLC control inverter method Mitsubishi PLC control inverter method

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

Confirmation and clearing of Mitsubishi inverter alarm history Confirmation and clearing of Mitsubishi inverter alarm history

When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...

The basic logic instructions of the Mitsubishi FX series plc The basic logic instructions of the Mitsubishi FX series plc

Fetch Command and Output Command (LD/LDI/LDP/LDF/OUT) (1) LD (take instruction) - the instruction that the normally open contact is connected with the left bus, and each - logic line that starts with the normally open contact is used with this instruction; (2) LDI ...

Mitsubishi PLC FX series programmers and other peripherals Mitsubishi PLC FX series programmers and other peripherals

1. FX series programmer The programmer is an important peripheral device of the PLC, which is used to write the user program to the PLC user program memory. On the one hand, it can be programmed by the PLC, and on the other hand, it can monitor the working status of the PLC. With the development of PLC skills, the multi-...

Introduction of Mitsubishi PLC series Introduction of Mitsubishi PLC series

1. Main substrate There are a variety of models such as Q32SB, Q33SB, Q35SB, Q33B, Q35B, Q38B, Q312B and other main substrates for Q series PLC, and the meaning of the model is as follows: In the meantime, the "S" stands for ultra-thin main substrate, and only Q61SP power modules can be used, and they cannot be ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top