When using Modbus communication in Mitsubishi PLCs, it is necessary to understand the address allocation of different register types.
The following are the common types of Mitsubishi PLC Modbus addresses and their corresponding functions:
1. Coil Register:
Address size: 0xxxx
Function: It is used to read and write logic switches, which can indicate the on/off status.
For example, 0xxxx corresponds to a Y address.
2. Discrete Input Registers:
Address size: 1xxxx
Function: Read-only logic switch for reading external input signals.
For example, 1xxxx corresponds to an X address.
3. Input Register:
Address size: 3xxxx
Function: Read-only 16-bit unsigned integer for reading analog quantity or condition information.
For example, 3xxxx corresponds to a D address.
4. Holding Register:
Address size: 4xxxx
Function: A 16-bit unsigned integer that reads and writes to store and correct data.
For example, 4xxxx corresponds to a D address.
It should be noted that the specific address size and function may vary according to different Mitsubishi PLC models and communication modules. Therefore, when using Modbus communication, it is recommended to refer to the manual of Mitsubishi PLC, or consult the relevant staff to obtain the corresponding information, in order to obtain accurate Modbus address allocation and operation guides.
|
More on that
|
Mitsubishi tells you what IGBT is
Mitsubishi Electric IGBT is the English word Insulated Gate Bipolar Transistor, which means insulated gate bipolar transistor in Chinese.
Functionally, IGBT is a circuit switch, and the advantage is that it uses electricity.
|
|
Mitsubishi inverter basic questions and answers
1. Question: What is the type of RS485 to RS232C converter used by Mitsubishi inverter for communication?
Solution: FA-T-RS40* Mitsubishi inverter is available.
2. Question: Mitsubishi inverter frequency external potentiometer is given, and the external potential recommended to be used ...
|
|
Mitsubishi inverter forward and reverse parameter adjustment
For the first time to use Mitsubishi inverter, the operation command and frequency command equipment may not be familiar, especially related to the setting of domestic inverter, the two parameters are separated. Mitsubishi's, on the other hand, are collectively referred to as the form of operation.
...
|
|
Mitsubishi PLC and computer communication setup method
After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings".
1. Connect the Mitsubishi PLC to the computer first.
2. Right-click on "My Computer" and select "Handle"...
|
|
PLC is different from each output type
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The biggest advantage is that it is suitable for high-frequency action, and the sound ...
|
|
Confirmation and clearing of Mitsubishi inverter alarm history
When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...
|
|
The Mitsubishi PLC FX2N is connected to a computer through the group Taiwang
In the PLC control system, the content that needs to be displayed mainly includes timer value, counter value and data register value, and the data display method can be summarized into two fundamental types: one is based on the PLC data communication interface, such as RS-232, RS-485/422, and the display device also has such an interface.
|
|
Mitsubishi controller and driver function and function
Functions and functions of the Mitsubishi controller:
To control the speed of the motor, the controller is also required to have corresponding maintenance functions such as brake power-off, under-voltage maintenance, under-voltage recovery value setting, over-current maintenance, etc. Some of the smart energy controllers also have multiple riding modes and have an electric ...
|
|
The inverter completes the multi-speed function - Mitsubishi
The inverter can be preset with a number of different speed points, and then complete the scheduling of multiple speed stages. The specific completion method is as follows:
You can set a number of different speed points in the VFD, and you can generally set the maximum speed, minimum speed, and several center speed points.
According to the needs, choose ...
|
|
Z series and A200 series inverter fault solving
Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC.
(1) Aging of the drive circuit
Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.
|
|
Advantages and disadvantages of different output types of Mitsubishi PLC
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The biggest advantage is that it is accustomed to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...
|
|
Mitsubishi is a method for completing the modification of timer setting outside the PLC
In the process of using the PLC control system, it is often necessary to correct some parameters, and the most common is to correct the set value of the timer. In order to facilitate the operator to correct the set value of the timer, the following methods can be used:
1. The use of man-machine ...
|
|
Mitsubishi inverter capacity and capacity selection
The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method.
1. When accelerating or operating at constant speed
The efficiency of the inverter is the output current, that is, ...
|
|
Mitsubishi FX series PLC fault diagnosis method
1. Power indication (LED indication) When power is supplied to the Mitsubishi PLC root unit, the [POWER] LED indicator light installed on the surface of the root unit turns on. If the power supply is closed but the [POWER] LED does not illuminate, please acknowledge the power wiring. In addition, if the same power supply has a drive sensor, etc. ...
|
|
AD PLC realizes the two basic points of control - Mitsubishi
PLC is based on electronic computers, but it is not the same as ordinary computers. Generally speaking, computers only consider the information itself when translating input and output information. As long as the human-machine interface is good, the input and output of information can be completed. And the PLC should also consider the information in and out ...
|
|
How does Mitsubishi PLC work?
1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting.
2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal.
3. The inner ...
|
|
Replacement steps for the internal battery of Mitsubishi PLC
When the battery voltage drops, the power supply is "ON", and the "BATT. V" LED lights up, and the battery is valid for one month from the time the light is on. However, there are times when it is found late, so after finding that the indicator light is on, the battery should be replaced as soon as possible to avoid power failure.
...
|
|
There are three major classifications of inverters - Mitsubishi inverters
There are several ways to classify frequency converters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
In accordance with the ...
|
|
Built-in time adjustment in Mitsubishi PLC
You can use two commands: TWR (Time Write) command and TRD (FNC166) TRD(P) command to adjust the built-in time.
1. TWR (Time Write) command
Instructions to write time presets to the built-in real-time clock: Clock ...
|
|
The basic composition of Mitsubishi PLC
Mitsubishi PLC is composed of power module, CPU module, input module, output module and substrate.
Power module: Provides DC5V power supply for each module on the substrate.
CPU module: It is the heart of the PLC. The CPU module consists of ...
|
|