If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain the function of a soft component; Disclaimer: Explain the function of a certain part of the program; Annotation: Explain the function of a certain circle and command.

                               Mitsubishi PLC Explanation Notes on the Final Statement

statement

Select the declaration icon in the menu bar, double-click the blank space on the left side of the program, pop up the interline declaration input, fill in the declaration, and check "Show to navigation window", so that you can display this declaration in the program itself, if you want to display this program alone, you can double-click to open it alone. Declarations are mainly used to classify programs into paragraphs, which is conducive to understanding the overall program architecture.

exegesis

There are three ways to set annotations. There are not many people who can switch between programming and annotation at any time. The second is the ability to annotate while programming, and most of them use this method. THE THIRD TYPE OF RIGHT-CLICK ANNOTATION IMPORTS AND EXPORTS FILES, WHICH CAN BE ANNOTATED IN EXCEL AND IS SUITABLE FOR LARGE PROJECTS.

Type: Select the annotation icon in the menu bar, double-click the soft component to be annotated, the annotation input window will pop up, write the annotation name, and click Confirm.

The second option: double-click the soft component to be annotated, select the annotation icon, click OK, write the annotation name, and click OK.

The third way: open the navigation - soft components - general soft component annotation, enter the software component name, and write the annotation name.

note

Select the annotation icon in the menu bar, double-click the coil output on the right side of the program, pop up the annotation input, fill in the annotation, and you can display the effect of the coil output instruction in the program.

More on that
Mitsubishi is a method for completing the modification of timer setting outside the PLC Mitsubishi is a method for completing the modification of timer setting outside the PLC

In the process of using the PLC control system, it is often necessary to correct some parameters, and the most common is to correct the set value of the timer. In order to facilitate the operator to correct the set value of the timer, the following methods can be used: 1. The use of man-machine ...

Mitsubishi inverter pre-use debugging steps Mitsubishi inverter pre-use debugging steps

1. No-load energizing test of Mitsubishi inverter. 1. Ground the ground terminal of the Mitsubishi inverter. 2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch. 3 Check whether the factory display window of Mitsubishi inverter is normal, if it is not correct.

Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models

FX2N-16MR Discontinued Replacement: FX3U-16MR/ES Input: 8 DC 24V Drain Output: 8 Relay FX2N-16MR-ES/UL Discontinued Replacement Model: FX3U-16MR/ES Input: 8 points DC24V drain/source output: 8 points Relay FX2N-16MS ...

PLC is different from each output type PLC is different from each output type

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is suitable for high-frequency action, and the sound ...

The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC

The difference between PLC and single-chip microcomputer: 1. PLC is a relatively sophisticated control system composed of single-chip microcomputer, and it is a product of the sophisticated and stable single-chip microcomputer application system that has been debugged. There is strong versatility. 2. The single-chip microcomputer can constitute a variety of application systems, and the scale of application ...

AD PLC realizes the two basic points of control - Mitsubishi AD PLC realizes the two basic points of control - Mitsubishi

PLC is based on electronic computers, but it is not the same as ordinary computers. Generally speaking, computers only consider the information itself when translating input and output information. As long as the human-machine interface is good, the input and output of information can be completed. And the PLC should also consider the information in and out ...

Mitsubishi drive functions and functions Mitsubishi drive functions and functions

1. Control the start, stop, speed and so on of the servo motor; 2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.) 3. React to external signals and control servo motors (position, speed, torque) through internal PID conditioning; ...

Mitsubishi PLC control system electroplating production line design Mitsubishi PLC control system electroplating production line design

Planning PLC control system control requirements for electroplating production line: 1) SQ1-SQ4 is the driving advance and retreat limit switch, and SQ5-SQ6 is the upper and lower limit switches. 2) The workpiece is lifted to SQ5 to stop, and the car is driven to SQ1 to stop.

How to adjust the jitter phenomenon of Mitsubishi servo motor How to adjust the jitter phenomenon of Mitsubishi servo motor

(1) Prerequisites Mitsubishi servo motors are able to improve the inertia of the motor by adjusting the gain, so as to adapt to the load, but the Mitsubishi servo motor is able to improve endlessly. Under normal circumstances, it is considered that it can withstand within 10-15 times of the additional inertia of the motor, and Mitsubishi reducer is required to be added in addition. We know ...

The relationship between torque and performance of Mitsubishi servo motors The relationship between torque and performance of Mitsubishi servo motors

1. Additional torque The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor. 2. Starting torque The torque generated by the motor at the moment when a voltage is applied to the motor in the aborted condition is called the starting torque. The starting torque characterizes the electrical...

Mitsubishi inverter control method Mitsubishi inverter control method

There are several ways to classify Mitsubishi inverters: According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; Depend on...

Mitsubishi Inverter F740 restores factory default Mitsubishi Inverter F740 restores factory default

Press the "SET" button to end the factory setting. Defects usually occur due to problems with the resistors or wiring of the voltage detection loop, rather than the actual undervoltage of the input voltage. OC disadvantages of the A200 series ...

Mitsubishi catalogue of some small PLC models and commonly used touch screens Mitsubishi catalogue of some small PLC models and commonly used touch screens

Commonly used touch screen model description Economical touch screen GS2107-WTBD 7 inch widescreen, 800*480, 65535 colors, USB/232/422/Ethernet, DC Pass through...

Features of Mitsubishi PLC commonly used models Features of Mitsubishi PLC commonly used models

FX Series PLC: FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in specification mode. In the meantime, the FX series 5U is suitable for any industry, and is used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

Mitsubishi PLC and computer communication setup method Mitsubishi PLC and computer communication setup method

After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings". 1. Connect the Mitsubishi PLC to the computer first. 2. Right-click on "My Computer" and select "Handle"...

Mitsubishi inverter installation reactor features Mitsubishi inverter installation reactor features

1. Characteristics of the output reactor: 1. It is suitable for reactive power compensation and harmonic control 2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. ** Ground protection of Mitsubishi inverter and improved power factor, can block from the grid ...

Differences in the output form of Mitsubishi PLC Differences in the output form of Mitsubishi PLC

Generally, there are three types of Mitsubishi PLC output circuit methods, namely: relay output type, transistor output type and thyristor output type. So what are the characteristics of each of them? First, the relay output circuit Use of relays ...

Introduction of Mitsubishi servo motor Introduction of Mitsubishi servo motor

Servo motor refers to the engine that controls the operation of mechanical components in the servo system, and is a kind of auxiliary motor indirect transmission device. The servo motor can make the control speed, azimuth accuracy is very precise, and can convert the voltage signal into torque and speed to drive the control target. Servo motor rotor speed ...

PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection ...

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top