Inverter life extension method - Mitsubishi

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

First, the frequency converter should not be installed on the equipment with a sensation, because the main circuit connection screw in the frequency converter is simply loose, and many frequency converters are damaged due to this reason.

Second, the wiring problem: the input end of the inverter is connected to an air, and the initial maintenance current should not be too large, so as to prevent incineration in the event of a short circuit. The "N" terminus must not be grounded. Try not to be too long with the control line. Because the control board is simply disturbed by electromagnetic waves and malfunctions, it will also cause damage to the control board, and more than 2 meters long can be shielded wire. Do not install a contactor with high current and often action around the inverter, because it disturbs the inverter very much, and often makes the inverter malfunction (showing various faults).

                               Inverter life extension method - Mitsubishi

Third, the inverter that often has to stop abruptly does not rely on the inverter's own brake, but adds another brake electric cathode or adopts mechanical brake, otherwise the inverter is often impacted by the motor back electromotive force, and the fault rate will be greatly improved.

4. If the inverter often runs at a low speed below 15HZ, the motor should add a cooling fan!

Fifth, dust and moisture are the deadly killers of inverters. The inverter can be installed in the air-conditioned room, or installed in the electric cabinet with dust nets, and the dust on the circuit board and radiator should be cleaned on time; The inverter that has been shut down for a period of time can use a hair dryer to blow the circuit board before powering it on.

More on that
Programmable Controller System Design and Debugging Steps – Mitsubishi PLC Programmable Controller System Design and Debugging Steps – Mitsubishi PLC

The main steps in the planning and commissioning of the programmable manipulator application system (1) In-depth understanding and analysis of the process conditions and control requirements of the controlled target a. The controlled target is a controlled mechanical, electrical equipment, production line or ...

Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution

On November 5, 2021, the 4th China International Import Expo was grandly held at the National Convention and Exhibition Center in Shanghai. At the 4th CIIE, Mitsubishi Electric's booth was located in Hall 4.1 of the Technical Equipment Zone of the Convention and Exhibition Center, with an exhibition space of 400 square meters. At Mitsubishi Electric's booth, the high-profile event was ...

Power factors affecting Mitsubishi inverters Power factors affecting Mitsubishi inverters

The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements: 1) The frequency conversion speed regulation system has low loss and high operating power. 2) The motor is always kept running at a low slip rate, which reduces the rotor loss.

The relationship between torque and performance of Mitsubishi servo motors The relationship between torque and performance of Mitsubishi servo motors

1. Additional torque The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor. 2. Starting torque The torque generated by the motor at the moment when a voltage is applied to the motor in a stopped condition is called the starting torque. The starting torque characterizes the electrical...

Mitsubishi PLC password protection settings Mitsubishi PLC password protection settings

In GX Works3, there are three types of security settings: block password, security key, and file password. The block password is for the program to prevent others from reading and writing changes, only for the program; The file password is for the PLC to prevent others from reading and writing changes. Security keys are both capable of ...

Introduction to the Mitsubishi PLC encryption process method Introduction to the Mitsubishi PLC encryption process method

The encryption process is as follows: ** Open the serial port for the first time [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here) [00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 1, Parity: Ev ...

Mitsubishi touch screen GT10 series models and their features Mitsubishi touch screen GT10 series models and their features

GT1020 touch screen ● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches ●3-color LED backlight for added visibility ●High brightness liquid crystal, clear under light ● Resolution 160×64, standard memory 512K ●Inside ...

One-button adjustment function for Mitsubishi servo motors One-button adjustment function for Mitsubishi servo motors

After the first installation of different servo motors on the machine, they may be poorly matched to the machine during operation, resulting in vibration, noise and other phenomena. The cause of the problem is a mismatch between parameters such as the rigidity of the servo motor and the load-inertia ratio and the machinery. Due to the large number of parameters that affect ...

The origin of Mitsubishi servo motion control is returned The origin of Mitsubishi servo motion control is returned

1. The so-called positioning is to let the servo motor go to a confirmed position. 2. This direction can be so incremental, or so ***. For example, we are now on the road, and we have to go forward 10 meters, which is equivalent to adding 10 meters to our bearing.

The interaction between the PLC and the touch screen is consistent - Mitsubishi The interaction between the PLC and the touch screen is consistent - Mitsubishi

When the contact screen is connected with the PLC, in fact, the memory of the PLC is used, (the contact screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the contact screen and the PLC communication is generally a master/slave relationship, that is, the contact screen reads data from the PLC, and after making a judgment, it is displayed in the display ...

There are three major classifications of inverters - Mitsubishi inverters There are three major classifications of inverters - Mitsubishi inverters

There are several ways to classify frequency converters: According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; In accordance with the ...

Advantages of Mitsubishi Electric fresh air system Advantages of Mitsubishi Electric fresh air system

Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just replace the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless. ...

Troubleshooting methods for Mitsubishi overload Troubleshooting methods for Mitsubishi overload

1. Check whether the motor is heated If the temperature rise of the motor is not high, the first thing to check is whether the electronic thermal protection function of the Mitsubishi inverter is preset reasonably, if the Mitsubishi inverter still has margin, the preset value should be relaxed; For example, the allowable current of Mitsubishi inverter is now out of margin, not ...

The wiring steps of the input and output circuits of the Mitsubishi PLC The wiring steps of the input and output circuits of the Mitsubishi PLC

The wiring diagram steps of the input and output circuit of Mitsubishi PLC, there are generally three types in the wiring diagram of the input and output of the PLC, one is DC 12-24V input, and there is output, so what about the external input? (1 ...

Mitsubishi PLC programming cable communication port setting method Mitsubishi PLC programming cable communication port setting method

1. Plug the programming cable into the USB port of the computer. 2. On the desktop, place the mouse on the "My Computer" icon, and then right-click. 3. In the pop-up menu, select "Device Manager". ...

Mitsubishi Electric MPD series IGBT modules Mitsubishi Electric MPD series IGBT modules

Mitsubishi Electric's newly developed new MPD series IGBT modules will be unveiled at PCIM Asia 2012 (BoothNo). :301) June 19-21 at the Shanghai World Expo Complex. The new MPD series is very suitable for water-cooled design, and is a high-current power supply with good heat dissipation performance and strong reliability.

Introduction to the selection conditions of Mitsubishi A840 series inverters Introduction to the selection conditions of Mitsubishi A840 series inverters

Q: When will I choose the A840 series inverter? A: A800 series inverters are generally used in heavy-duty occupations, such as lifting occupations, mixer occupations will use A800 series. At the same time, it is a vector inverter, so customers need to do closed-loop speed control, torque control may ...

The difference between a motion controller and a PLC – Mitsubishi The difference between a motion controller and a PLC – Mitsubishi

1. Motion manipulator The use of motion control in the field of robotics and CNC machines is more chaotic than in specialized machines, which are more sketchy and often referred to as General Motion Control (GMC). 2.plc Programmable logic manipulators are a kind of specialized ...

Mitsubishi Electric one-click adjustment user instruction mode tuning method Mitsubishi Electric one-click adjustment user instruction mode tuning method

1. Set PA08 to 0003 and set the gain adjustment form to; , the function is to prevent the failure of the active calculation of the inertia ratio, and the alarm C005 will be given. 2. Flip it over; menu; , set the speed/acceleration and deceleration/movement amount, according to the actual situation ...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top