The weight conversion method of the Mitsubishi weigh module
Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...
|
|
Mitsubishi FR-E800 product model introduction
1、3相200V FR-E820-[]K (E)
FR-E820-0.1K、FR-E820-0.2K、FR-E820-0.4K、FR-E820-0.75K、FR-E820-1.5K、
FR-E820-2.2K、FR-E820-3.7K、FR-E820-5.5K、FR-E820-7.5K、FR-E820-11K、
...
|
|
Advantages and disadvantages of Mitsubishi's different output types
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The biggest advantage is that it is adapted to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
Power factors affecting Mitsubishi inverters
The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements:
1) The frequency conversion speed regulation system has low loss and high operating power.
2) The motor is always kept running at a low slip rate, which reduces the rotor loss.
|
|
Programmable Controller System Design and Debugging Steps – Mitsubishi PLC
The main steps in the planning and commissioning of the programmable manipulator application system
(1) In-depth understanding and analysis of the process conditions and control requirements of the controlled target
a. The controlled target is a controlled mechanical, electrical equipment, production line or ...
|
|
The relationship between torque and performance of Mitsubishi servo motors
1. Additional torque
The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor.
2. Starting torque
The torque generated by the motor at the moment when a voltage is applied to the motor in the aborted condition is called the starting torque. The starting torque characterizes the electrical...
|
|
Differences in the output form of Mitsubishi PLC
Generally, there are three types of Mitsubishi PLC output circuit methods, namely: relay output type, transistor output type and thyristor output type. So what are the characteristics of each of them?
First, the relay output circuit
Use of relays ...
|
|
Mitsubishi PLC Explanation Notes on the Final Statement
If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...
|
|
Mitsubishi A800 series inverter realizes motor self-learning
Set it up as follows:
Press PU/EXT to switch to PU format
Pr.9 = additional current of the motor
Pr.71=3 (ordinary motor) or 13 (constant torque motor)
Pr.80 = motor power
Pr.81 = number of poles of the motor ( ...
|
|
Precautions for the use of Mitsubishi servo motor with brake
1. Occasions with brake servo motors:
The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...
|
|
Inverter overload fault factor - Mitsubishi inverter
1) The mechanical load is too heavy
The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...
|
|
Mitsubishi FX series PLC master control command
The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs.
Master Control Command (MC/MCR)
(1) MC (Master Control Command) for common tandem contacts ...
|
|
Classification of Mitsubishi touch screens
At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors.
1. Resistive contact screen
The screen body of the resistive contact screen ...
|
|
Mitsubishi Inverter F740 restores factory default
Press the "SET" button to end the factory setting.
Defects usually occur due to problems with the resistors or wiring of the voltage detection loop, rather than the actual undervoltage of the input voltage. OC disadvantages of the A200 series ...
|
|
How to write a holding circuit for Mitsubishi PLC
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Mitsubishi PLC main maintenance and overhaul content points
The main content of the protection and maintenance of Mitsubishi PLC
Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...
|
|
The built-in analog quantity of the Mitsubishi PLC function module is changed to current input
Mitsubishi FX5UCPU module has a built-in analog input as a voltage input (DC0-10V),
In this way, it can be converted into an analog current input (DC4 - 20m).
[Method used in current input (DC4 - 20mA)]
FX5UCPU module only supports voltage ...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation imitation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. Assuming that the load on the motor shaft is less than 2.5Nm, then ...
|
|
Z series and A200 series inverter fault solving
Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC.
(1) Aging of the drive circuit
Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.
|