Mitsubishi PLC programming cable communication port setting method

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. Plug the programming cable into the USB port of the computer.

2. On the desktop, place the mouse on the "My Computer" icon, and then right-click.

                               Mitsubishi PLC programming cable communication port setting method

3. In the pop-up menu, select "Device Manager".

4. Find your programming cable port number in the "Ports" list. Hover over the port number, right-click, and select "Features" in the pop-up menu.

5. In the feature window, you can correct the port number, and you can correct the port number to the same number. The port of the computer and the port of the Mitsubishi PLC programming software must be set, under normal circumstances, the default of the desktop computer is COM1, and the software is also changed to COM1 after the restart of the software can be, the USB port is often set up after the common unplugged reconnection, and restart the software, but sometimes it is a problem with the communication line, try to change the root. It may be that the communication port is broken, and I have encountered it a few times, caused by hot plugging, but it can still be used after it is broken.

More on that
The weight conversion method of the Mitsubishi weigh module The weight conversion method of the Mitsubishi weigh module

Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...

Mitsubishi FR-E800 product model introduction Mitsubishi FR-E800 product model introduction

1、3相200V FR-E820-[]K (E)   FR-E820-0.1K、FR-E820-0.2K、FR-E820-0.4K、FR-E820-0.75K、FR-E820-1.5K、   FR-E820-2.2K、FR-E820-3.7K、FR-E820-5.5K、FR-E820-7.5K、FR-E820-11K、 ...

Advantages and disadvantages of Mitsubishi's different output types Advantages and disadvantages of Mitsubishi's different output types

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is adapted to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...

The connection of the Mitsubishi inverter FR-A800 The connection of the Mitsubishi inverter FR-A800

The connection of the Mitsubishi inverter FR-A800

Power factors affecting Mitsubishi inverters Power factors affecting Mitsubishi inverters

The speed regulation of Mitsubishi inverter power regulator is adopted, one is to regulate the speed according to the requirements, and the other is to save energy. It is based on the following elements: 1) The frequency conversion speed regulation system has low loss and high operating power. 2) The motor is always kept running at a low slip rate, which reduces the rotor loss.

Programmable Controller System Design and Debugging Steps – Mitsubishi PLC Programmable Controller System Design and Debugging Steps – Mitsubishi PLC

The main steps in the planning and commissioning of the programmable manipulator application system (1) In-depth understanding and analysis of the process conditions and control requirements of the controlled target a. The controlled target is a controlled mechanical, electrical equipment, production line or ...

The relationship between torque and performance of Mitsubishi servo motors The relationship between torque and performance of Mitsubishi servo motors

1. Additional torque The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor. 2. Starting torque The torque generated by the motor at the moment when a voltage is applied to the motor in the aborted condition is called the starting torque. The starting torque characterizes the electrical...

Differences in the output form of Mitsubishi PLC Differences in the output form of Mitsubishi PLC

Generally, there are three types of Mitsubishi PLC output circuit methods, namely: relay output type, transistor output type and thyristor output type. So what are the characteristics of each of them? First, the relay output circuit Use of relays ...

Mitsubishi PLC Explanation Notes on the Final Statement Mitsubishi PLC Explanation Notes on the Final Statement

If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...

Mitsubishi A800 series inverter realizes motor self-learning Mitsubishi A800 series inverter realizes motor self-learning

Set it up as follows: Press PU/EXT to switch to PU format Pr.9 = additional current of the motor Pr.71=3 (ordinary motor) or 13 (constant torque motor) Pr.80 = motor power Pr.81 = number of poles of the motor ( ...

Precautions for the use of Mitsubishi servo motor with brake Precautions for the use of Mitsubishi servo motor with brake

1. Occasions with brake servo motors: The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...

Inverter overload fault factor - Mitsubishi inverter Inverter overload fault factor - Mitsubishi inverter

1) The mechanical load is too heavy The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...

Mitsubishi FX series PLC master control command Mitsubishi FX series PLC master control command

The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs. Master Control Command (MC/MCR) (1) MC (Master Control Command) for common tandem contacts ...

Classification of Mitsubishi touch screens Classification of Mitsubishi touch screens

At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors. 1. Resistive contact screen The screen body of the resistive contact screen ...

Mitsubishi Inverter F740 restores factory default Mitsubishi Inverter F740 restores factory default

Press the "SET" button to end the factory setting. Defects usually occur due to problems with the resistors or wiring of the voltage detection loop, rather than the actual undervoltage of the input voltage. OC disadvantages of the A200 series ...

How to write a holding circuit for Mitsubishi PLC How to write a holding circuit for Mitsubishi PLC

There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit. ...

Mitsubishi PLC main maintenance and overhaul content points Mitsubishi PLC main maintenance and overhaul content points

The main content of the protection and maintenance of Mitsubishi PLC Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...

The built-in analog quantity of the Mitsubishi PLC function module is changed to current input The built-in analog quantity of the Mitsubishi PLC function module is changed to current input

Mitsubishi FX5UCPU module has a built-in analog input as a voltage input (DC0-10V), In this way, it can be converted into an analog current input (DC4 - 20m). [Method used in current input (DC4 - 20mA)] FX5UCPU module only supports voltage ...

Mitsubishi servo motor is now commonly used Mitsubishi servo motor is now commonly used

1. Torque control: Torque control is based on external simulation imitation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. Assuming that the load on the motor shaft is less than 2.5Nm, then ...

Z series and A200 series inverter fault solving Z series and A200 series inverter fault solving

Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC. (1) Aging of the drive circuit Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top