In some cases, when the user first touches the use of the Mitsubishi servo motor, it may appear that the Mitsubishi servo motor is not self-locking after it is ready! So, what is the reason for this? And how to deal with it?
In fact, it is very simple, if the Mitsubishi servo motor is not self-locking after preparation, then it is generally due to wiring fault.
At this moment, it is generally presented that there will be no alarm when clicking on the power-on, and if the PLC is controlled, part of the output on the PLC can be successfully output, but the servo motor cannot be operated, and the alarm will be presented.
How to deal with it?
If the above situation is presented, then the user only needs to check whether the wiring of the servo motor is correct, and after finding the wrong wiring, adjust it in time and connect the line correctly.
However, if it is not a problem with the wiring, then you need to check whether the amplifier is ready and other aspects.
|
More on that
|
The built-in analog quantity of the Mitsubishi PLC function module is changed to current input
Mitsubishi FX5UCPU module has a built-in analog input as a voltage input (DC0-10V),
In this way, it can be converted into an analog current input (DC4 - 20m).
[Method used in current input (DC4 - 20mA)]
FX5UCPU module only supports voltage ...
|
|
How to deal with Mitsubishi PLC failures - Mitsubishi
01. Base system problem
In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base.
2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...
|
|
Mitsubishi FX5U series PLC ten advantages
1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input ...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
Mitsubishi catalogue of some small PLC models and commonly used touch screens
Commonly used touch screen model description
Economical touch screen GS2107-WTBD 7 inch widescreen, 800*480, 65535 colors, USB/232/422/Ethernet, DC
Pass through...
|
|
How Mitsubishi PLC works
A. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting.
B. Each scanning process. The convergence samples the input signal. The convergence rewrites the output signal.
C. Component image register ...
|
|
The basic composition of Mitsubishi PLC
Mitsubishi PLC is composed of power module, CPU module, input module, output module and substrate.
Power module: Provides DC5V power supply for each module on the substrate.
CPU module: It is the heart of the PLC. The CPU module consists of ...
|
|
Mitsubishi 30MA-eX-F40 fiber laser flexible automatic loading and unloading system
The 30MA-eX-F40 fiber laser flexible active loading and unloading system was jointly developed by Mitsubishi Electric Corporation's Laser Division and Mitsubishi Electric Electromechanical Technology Co., Ltd.
...
|
|
Ground leakage current of Mitsubishi inverter and countermeasures thereof
There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.
|
|
The difference between Mitsubishi FX3u and FX5u
Mitsubishi FX3U series PLC is the third generation of miniature programmable manipulators, using a class of programmable memory for its internal storage programs, to execute logic operations, sequence control, timing, counting and arithmetic operations and other user-oriented instructions, and through digital or analog input/output control of each ...
|
|
Mitsubishi inverter FR-E024-0.75K repair
Type: FR-E024-0.75K
Fault: The boot cannot be started
Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...
|
|
The protection function of the inverter to the motor - Mitsubishi
The inverter is the control equipment for the operation of the motor, and it has a certain maintenance function for the motor. Most of the inverter appliances have functions such as overvoltage, overcurrent, undervoltage and overload maintenance.
Overcurrent maintenance function. In any link of motor acceleration, deceleration and constant speed operation, ...
|
|
Inverter life extension method - Mitsubishi
First, the frequency converter should not be installed on the equipment with a sensation, because the main circuit connection screw in the frequency converter is simply loose, and many frequency converters are damaged due to this reason.
Second, the wiring problem: the input end of the inverter is connected to an air The initial maintenance current should not be too large, ...
|
|
The difference between the performance of Mitsubishi servo motor and stepper motor
First, the control accuracy is different
The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors with smaller step angles after subdivision. Communicate the control of servo motor ...
|
|
Explanation of Mitsubishi pIc source type and drain type
The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal.
The general input points are ...
|
|
PLC Processor Performance Test – Mitsubishi
The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...
|
|
Review and comparison of Mitsubishi PLC control inverter methods
1. The switching signal of PLC controls the inverter
The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...
|
|
Application of Mitsubishi FX PLC in speed measurement
[Example] a motor is equipped with an optical encoder (the optical encoder is coaxially installed with the motor), and the FX2N-32MT is used to measure the speed of the motor.
【Solution】
Because the photoelectric encoder is coaxially installed with the motor, the ...
|
|
Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models
FX2N-16MR Discontinued Replacement: FX3U-16MR/ES Input: 8 DC 24V Drain Output: 8 Relay
FX2N-16MR-ES/UL Discontinued Replacement Model: FX3U-16MR/ES Input: 8 points DC24V drain/source output: 8 points Relay
FX2N-16MS ...
|
|
Mitsubishi servo system failure type
The origin orientation is incorrect, and the encoder debugs/zeros the bit
Replacement of bearings, wear of bearing grooves, cracking of the rotor, cracking of the shaft
Gear groove wear
The magnet bursts steel, the magnet falls, gets stuck and doesn't move
Encoder wear, code/glass disc wear and crack
...
|
|