1. The sensor should be handled gently, especially for the small range sensor with aluminum alloy material as the elastomer, any impact or drop caused by vibration is likely to cause a large output error. In addition, it is necessary to protect the sensor outlet head and not to break it
2. When designing and installing the loading device, it should be ensured that the line of action of the loading force coincides with the axis of the force of the sensor, so as to minimize the influence of inclined load and eccentric load.
3. To prevent chemical corrosion. It is advisable to apply petroleum jelly to the outer surface of the tension transducer during installation. It should be avoided in direct sunlight and in places where the ambient temperature changes drastically, and protective or mitigation devices should be installed when it cannot be avoided.
4. In order to prevent the sensor from being damaged by the large current directly passing through the sensor body, it is forbidden to carry out electric welding operations after the sensor is installed, and the bypass made of copper braided wire should be added at both ends of the sensor loading device as a last resort.
5. The cable should not be lengthened by itself, and should be soldered at the joint when it is really needed to be lengthened, and moisture-proof sealant should be added.
6. The cable of the sensor should be kept away from the strong power supply line or the place with pulse wave, and the cable of the sensor should be inserted into the iron pipe separately when it cannot be avoided, and the connection distance should be shortened as much as possible.
7. In the case of high-precision use, the sensor and instrument should be used after 30 minutes of preheating.
8. The sensor should be stored in a dry, ventilated and non-corrosive gas room.
|
More on that
|
Debugging method of Sick fiber optic sensor 180T
1. First, connect the external hardware and install the external COM port of the scanner to the serial port of the industrial computer.
2. The power supply of the SICK scanner control box is 24V positive and negative induction eyes, and the feedback signals of 10, 11 and 12 corresponding to the electric eyes, 24V+, 24V-.
...
|
|
Sick Sensors - Applications and Attention Problems of Infrared Sensors
Infrared sensors are sensors that use the physical properties of infrared rays to make measurements. Infrared, also known as infrared light, has the properties of reflection, refraction, scattering, interference, absorption, etc. Any substance that has a certain temperature above absolute zero can radiate infrared rays. ...
|
|
Sick Sensors – How to use the Contrast Sensor
1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...
|
|
Common fault causes and treatment methods of Sick sensors
1. No weighing reading
This kind of fault is generally more common, the weighing value of a certain scale is zero, regardless of whether there is something on the scale, its weighing value is always zero.
There are several reasons for the above failure: a. the sensor is damaged, b. the line is open, c. the signal is ...
|
|
Sick Sensors - Classification of RTD Sensors and Their Characteristics and Uses
1. NTC RTD Sensor:
Features: This kind of sensor is a negative temperature coefficient sensor, that is, the sensor resistance decreases with the increase of temperature;
Application: NTC thermistors are commonly used as temperature measurement tools on the air side and medium side in automotive thermal management systems, such as evaporation.
|
|
New Arrivals | Sick DLS40 incremental encoder
As we all know, incremental encoders are used to monitor rotational speed or position, and are widely used in all kinds of automated machinery. With the continuous development of the industrial control industry and the continuous change of product demand, SICK has launched a more cost-effective and cost-effective small incremental encoder market in the large and competitive small incremental encoder market.
|
|
How to adjust the sensor of Sick NT6-03022? What are the methods?
1. Self-regulation. At the beginning of use, please check whether the switch itself is in good condition, whether the appearance is in good condition, etc.
2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...
|
|
Sick Sensors – Common faults in pressure sensors
One. The pressure can go up, but the transmitter output can't go up
In this case, you should first check whether there is a leak in the pressure interface or it may be blocked, if it is confirmed, then check whether the wiring method is wrong and check the power supply, if the power supply is normal, you should simply pressurize to see if the output is ...
|
|
For the 20th year in a row, SICK Germany has been on the list of "Best Employers in Germany".
SICK Germany has been ranked 2nd in the list of "Best Employers in Germany 2022"! For 20 years in a row, SICK has been on the list of "Best Employers in Germany"! The list is published by the Great Place to Work Institute®, the world's leading ...
|
|
Sick Sensors – How to deal with failures in AGC displacement sensors
(1) Measure the clock signal and data signal of the displacement sensor of 4 hydraulic cylinders, the clock signal is about 2.8V DC and 0.123V AC; The data signals are all about 2.8V DC and 0.245V AC. From this, it can be judged that the PLC clock and MTS data bit transmission and reception pulse loops are normal ...
|
|
Sick's 3D vision product Ruler3000 series has been expanded with two new members
Two new members of the Ruler3000 family of Sick 3D vision products have been added, named Ruler3120 and Ruler3008.
The new 3D vision sensor solution Ruler3000 from SICK is suitable for a wide range of industrial applications and is characterized by its high speed and image quality.
3D Visual Transmission ...
|
|
Sick Sensors – the principle and practical application of color mark sensors
Principle:
Contrast sensors are often used to detect spots on specific color marks or objects, and they are used to detect color marks by comparing them to non-color mark areas, rather than directly measuring color. The color mark sensor is actually a reverse device, where the light source is mounted perpendicular to the target object, and the receiver is connected to the ...
|
|
Adjustment method of sensing distance of Sick photoelectric sensor
1. Find the screw at the end of the switch, twist it clockwise to adjust it far, and twist it counterclockwise to adjust it closer.
2. It can increase the intensity of the light source.
3. Improve the sensitivity of the switch sensor.
4. It can also be adjusted according to the instructions for use.
...
|
|
Sick Sensors – Precautions for the use of color mark sensors
1. Be sure to check whether the power supply used is in line with DC12-24V±10%, and the maximum is not more than 40V, otherwise the photoelectric switch may be damaged.
2. In order to ensure high stability detection, it is necessary to ensure that two points are achieved: first, the detection distance meets the specified rated detection distance, such as the detection distance is 12±2mm ...
|
|
Sick Sensors - How to test the quality of load cells?
The load cell is a relatively easy to damage component in the weighing cell, and it is easy to cause damage to the sensor due to impact, overload, aging, high temperature, corrosion, etc.
(1) Physical observation: observe whether the appearance of the load cell is deformed, cracked, etc.
(2) Measure the resistance ...
|
|
Sick Sensors – Where can ultrasonic sensors not be used?
(1) When the target to be measured is not perpendicular to the transducer of the sensor. This is because the target of the ultrasonic test must be within an angle of no more than 10° perpendicular to the sensor.
(2) When a small beam diameter is required. Because the diameter of the general ultrasonic beam is ...
|
|
Sick sensor - introduction to the characteristics of photoelectric sensors
1. Long detection distance
If the detection distance of 10 m or more is retained in the through-beam type, it is possible to achieve detection that is not possible with other detection methods (magnetic, ultrasonic, etc.).
2. There are few restrictions on the detected objects
Due to the detection of shading and reflection caused by the detection of objects ...
|
|
What are the characteristics of Sick Sensors – Contrast Sensors?
1. Accuracy
2. Environmental conditions
3. Wavelength range
4. Calibration
5. Resolution
6. Cost
7. Repeatability
8. Frequency
|
|
An introduction to the classification of Sick sensors
1. Industrial sensors
The SICK industrial sensor portfolio includes the widest range of photoelectric sensors, fiber optic amplifiers, color mark sensors, proximity sensors, magnetic cylinder sensors, and measuring light curtains in the automation sector, which are mainly used for: recording, counting, classifying, and positioning objects.
|
|
New Arrivals | Sick safety locking device FLEXLOCK
SICK's new generation of RFID monitoring security locking device FLEXLOCK is officially launched.
The FLEXLOCK safety locking device for RFID monitoring has an operating radius of 180° for greater flexibility and is also suitable for protective doors with smaller radii. LED lights can be selected from ...
|
|