1. Open-loop control
There is no reverse connection between the controller and the controlled target, and the control is carried out in one direction.
Strengths: Simple, stable and reliable. If the characteristics and parameter values of the components that make up the system are relatively stable, and the external disturbance is small, the open-loop control energy
enough to maintain a certain level of accuracy.
Defects: The accuracy is generally low, and there is no active deviation correction ability.
2. Closed-loop control
Characteristics of closed-loop control system: There is a reaction loop between the output and the input end, and the output has a direct impact on the control process. Closed-loop effect: Use reactions to reduce deviations.
Advantages: High accuracy, insensitive to external disturbances and changes in system parameters
Defects: There are problems such as stability, oscillation, overshoot, etc., and the system performance analysis and planning are troublesome.
|
More on that
|
Introduction to common models and parameters of Delta touch screens
There are many types of Delta contact screens, of course, the parameters of different types are different, and the most important product is DOP-B03S201. This product is a 4.3-inch screen, its aspect ratio is 16:9, the screen is made of TFT raw materials, and its resolution can reach 480X ...
|
|
Delta's inverter and output reactor function
input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the function and service life of the inverter and the motor, so it is necessary to install a transmission system in front of it.
|
|
Problems in the inverter application – Delta inverters
1. Harmonic problems
The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...
|
|
The parameter that needs to be set for the inverter - Delta
There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance.
General-purpose inverters generally have dozens or even hundreds of functional parameters.
|
|
Pulse control wiring method for Delta servo drives
Parameter settings
P1-XX are the basic parameters
P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction
P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX
P1-01 Control form selection, pick ...
|
|
Precautions for cleaning dust in the inverter - Delta
1. Each VFD should be cleaned and protected once a quarter. Protecting and cleaning equipment must have specific records and the signature of the person in charge. As long as the management is in place, the task can be completed with quality and quantity;
2. Before cleaning, the power supply must be blocked, and the voltage must be reduced to a safe voltage before starting to work.
...
|
|
Selection of inverter box structure - Delta
The box structure of the inverter should be adapted to the environmental conditions, that is, the temperature, humidity, dust, pH, corrosive gas and other elements must be considered. There are several common types of structures that users can choose from:
1) Open IPOO ...
|
|
Delta's N 1-3kVA series has three core advantages
In addition to adhering to the high reliability, excellent efficiency and outstanding power of Delta's UPS products, the N1-3kVA series has three obvious core advantages:
1. High availability planning
Delta N 1-3kVA series ...
|
|
Delta's power supply series application considerations
(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...
|
|
Precautions before installation of Delta inverters
Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows:
1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...
|
|
Installation requirements for inverter energy consumption braking - Delta inverter
(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current.
(2) The brake unit is working ...
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Selection of braking resistors for Delta inverters
1. The necessity of braking resistance
If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage.
Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...
|
|
Delta servo problem analysis
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic plate, so that the magnetic field generated by the stator coil can control the orientation of the rotor, and the acceleration and deceleration characteristics are ...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
The principle structure of low-voltage circuit breaker - Delta
Low-voltage circuit breakers, commonly known as active air switches, are one of the primary electrical switches in low-voltage distribution networks. It can not only turn on and off normal load current, motor operation current and overload current, but also turn on and off short circuit current.
It is mainly used as a low-voltage distribution line or a switch cabinet that is not often operated ( ...
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
How Delta's touch screen works
Delta's touch screen consists of a contact detection component and a touch screen controller.
The contact detection component is installed in front of the display screen to detect the user's contact orientation and is sent back to the touch screen controller; And Delta's touch screen controller's ...
|
|
Do Delta thermostats have a "slope control" function?
Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function.
Illustrate the following examples:
For example: PV=20°C, SV=100°C, slope 10.0°C/min
Then (100 – 20)/10.0 ...
|
|
Brand inverter modifies the power method - Delta
What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.
|
|