The output side of the inverter is equipped with a contactor - Sunland inverter

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

When the power supply and the inverter are replaced, for example, if the inverter has a problem, in order to make an emergency, let the motor be directly changed to be driven by the power frequency power supply; Perhaps the inverter is used for soft starting, and after the motor is accelerated to the power frequency speed, it is changed to be driven by the power frequency power supply.

                                  The output side of the inverter is equipped with a contactor - Sunland inverter

When multiple motors are replaced, when the capacity margin of the inverter is large, one inverter can drive multiple motors to operate, which is called group operation. However, these motors do not start or stop together, and sometimes one motor may be directly involved in the variable frequency operation when other motors are running steadily. Conversely, when multiple motors are running together, sometimes one motor is overloaded or has a problem that needs to be withdrawn. Considering the above situation, it is often necessary to add a contactor on the output side of the inverter.

In principle, do not let the stopped motor suddenly pull into the operation during the operation of the inverter, especially during frequent operation, and simply damage the inverter. In addition, regarding the power frequency power supply and the inverter replacement drive motor operation system, it is necessary to pay attention to the phase sequence of the two power supplies to ensure that the motor steering is common.

When the power supply and the inverter are replaced, for example, if the inverter has a problem, in order to make an emergency, let the motor be directly changed to be driven by the power frequency power supply; Perhaps the inverter is used for soft starting, and after the motor is accelerated to the power frequency speed, it is changed to be driven by the power frequency power supply.

When multiple motors are replaced, when the capacity margin of the inverter is large, one inverter can drive multiple motors to operate, which is called group operation. However, these motors do not start or stop together, and sometimes one motor may be directly involved in the variable frequency operation when other motors are running steadily. Conversely, when multiple motors are running together, sometimes a motor is overloaded or needs to be withdrawn. Considering the above situation, it is often necessary to add a contactor on the output side of the inverter.

In principle, do not let the stopped motor suddenly pull into the operation during the operation of the inverter, especially during frequent operation, and simply damage the inverter. In addition, regarding the power frequency power supply and the inverter replacement drive motor operation system, it is necessary to pay attention to the phase sequence of the two power supplies to ensure that the motor steering is common.

More on that
The difference between strong and weak inverter - Sunland inverter The difference between strong and weak inverter - Sunland inverter

The inverter includes a rectifier circuit and an inverter circuit, and the input communication electricity is converted into DC voltage through the rectifier circuit and flat-wave circuit, and then through the difference between strong and weak current, it is mainly reflected in the different uses. Strong electricity is used as a kind of power power, and weak electricity is used for information transmission. In detail ...

Wiring specification of inverter control cabinet - Senland Wiring specification of inverter control cabinet - Senland

The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...

Servo motor regular diagnosis and repair method - Senlan Servo motor regular diagnosis and repair method - Senlan

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line

In order to thoroughly implement the spirit of General Secretary Xi Jinping's important instructions that the economic power must be a maritime power, a shipping power, economic development, a strong country, and transportation, especially shipping, and the implementation of the outline for the construction of a transportation power, the port ship shore power system has become the standard for green ports.

The cause of leakage of the inverter-controlled motor - Senlan The cause of leakage of the inverter-controlled motor - Senlan

In some fields, the use of inverter to control the motor will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. According to the inverter control motor ...

The remote control of the inverter meets the function - Sunland inverter The remote control of the inverter meets the function - Sunland inverter

In general, the long-distance operation of the frequency converter requires the following functions: 1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required. 2) Long-distance start-stop, long-distance start or stop inverter, and ...

The cause of the leakage problem of Sunland inverter The cause of the leakage problem of Sunland inverter

1. The cause of inverter leakage According to the inverter to control the operation of the motor, the three-phase electricity is supplied to the inverter bridge (IGBT) through the filter capacitor through the rectification, and then the operation of the motor is controlled by the three-phase electricity with adjustable output frequency and voltage of the inverter. We all know that the three-phase stator winding of the motor ...

Common brand inverter modification power method - Senlan inverter Common brand inverter modification power method - Senlan inverter

What are the advantages of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters. ...

Senlan SV1000 servo drive check before power-on Senlan SV1000 servo drive check before power-on

1) Oil circuit inspection: Open the safety valve to check whether there is any leakage in the oil circuit. 2) Line check: whether the R, S, T, PE on the input side of the driver, U, V, W, PE lines on the output side and the control line are corresponding. 3) Check whether the power supply voltage of the incoming terminal of the servo drive is normal ...

I/O (Input/Output) Selection – Senland I/O (Input/Output) Selection – Senland

In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O). ...

Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany

November 24, 2015 - November 26, 2015, "Germany Nuremberg Industrial Automation Exhibition" was successfully carried out at the Nuremberg International Exhibition Center in Germany, and it is expected that Sunland as a domestic professional inverter manufacturer also participated in the exhibition, in this exhibition, in addition to the usual SB70, ...

The reason for the increase of the torque of the inverter - Senlan inverter The reason for the increase of the torque of the inverter - Senlan inverter

It is important to set the torque to improve the function. When the power frequency of the motor decreases, the speed of the motor will also decrease, and if the load torque remains unchanged, the output power will also decrease. According to the principle of conservation of energy, if the rotation of the load ...

I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair

From September 15th to 19th, the 22nd China International Industry Fair was held at the National Convention and Exhibition Center (Shanghai). As the first national industrial exhibition held under the normalization of epidemic prevention and control this year, the theme of this expo is "Intelligence, Interconnection: Enabling the New Development of Industries".

Hope the advantages of Sunland inverter soft start Hope the advantages of Sunland inverter soft start

It is hoped that Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which can meet the needs of various applications. The advantages of Hope Sunland inverter and soft start are: 1. **Sex: I hope that Sunland inverter and ...

Inverter water inlet maintenance method - Sunland inverter Inverter water inlet maintenance method - Sunland inverter

The first step is not to turn on electricity! First open the inverter panel, wipe the inverter dry, and then use a hair dryer to dry the display, PC board, push board, power components, fans, etc., with 95% alcohol, scrub the components with 95% alcohol, and dry the hair dryer with cold air. Step 2: After an hour, use alcohol ...

The comprehensive application of Sunland's high-power boiler feed pump has added another classic The comprehensive application of Sunland's high-power boiler feed pump has added another classic

Recently, the "General Contracting Project of Boiler Feed Pump Frequency Conversion Technology Transformation Project of Yili Power Plant of Guoshen Group" undertaken by Hope Sunland has been successfully implemented and connected to the grid, adding another classic to the comprehensive application of Sunland's high-power boiler feed pump. In 2020 ...

Sunland - inverter operation process and factory value restoration Sunland - inverter operation process and factory value restoration

The general operation process is as follows: Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...

Selection and capacity matching of inverter - Senlan Selection and capacity matching of inverter - Senlan

1. Select the inverter according to the load characteristics Second, when selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the extra power of the motor can only be used as a reference. Secondly, it should be fully considered that the output of the inverter contains higher harmonics, which will form the power factor of the motor.

Sunland inverter control panel button function Sunland inverter control panel button function

1. The "FUNC/DATA" key is a programming key, press this button once to convert the operation mode, and press it again to read and write the function code; 2. The "SET/>>" button is the display switch and shift key, press this key to switch the display content, and press it again to ...

A contactor is used between the inverter and the motor - Senlan inverter A contactor is used between the inverter and the motor - Senlan inverter

Whether a contactor is used between the inverter (VFD) and the motor depends on the specific situation. When the contactor is on and off when the motor is running, the operating overvoltage is easy to cause VFD damage. Therefore, whether to use the contactor, it must be based on the actual situation to make the correct ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top