Schneider pushbutton switch type
(1) Protective button: a kind of button with a protective shell that can prevent the internal button parts from being mechanically damaged or people touching the live part, and its code is H.
(2) Dynamic break button: Under normal conditions, the switch contact is a kind of button that is turned on.
(3) Dynamic button: Under normal conditions, the ...
|
|
Inverter braking resistor selection – Schneider
In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...
|
|
Key points of operation of Schneider disconnectors
Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, Schneider barrier switches can cooperate with circuit breakers to change the operation of the system.
|
|
Pay attention to the problem of false load connection method in inverter debugging - Schneider
There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...
|
|
There is no indication on the UPS boot panel that UPS is not working - Schneider
Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop:
1. Check whether the mains input wire is incinerated;
2. If the mains input is stable...
|
|
Introduction to the transformer connection group - Schneider
In the transformer planning process, the choice of wiring method is often not paid attention to. The three-phase transformer has A/B/C three-phase winding on the 1/2 side. The connection between them has a great impact on the operation performance of transformers, especially distribution transformers, and directly affects the quality of power supply. Therefore, the wiring ...
|
|
The inverter controls the speed of the AC motor – Schneider
Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...
|
|
Schneider servo motor advantages
Schneider servo motor is one of the brands of servo motor, the performance is relatively good, is a brand made in Germany, in China ** degree is relatively high. Servo motor refers to the servo system, (servomechanism) in which the mechanical components are controlled.
|
|
Introduction to Schneider inverter inverter
The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to a certain law, and the motor strictly follows the dynamic and stop command action of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping.
The full name of Schneider inverter is "...
|
|
Analysis of the reasons why the contact of Schneider contactor is not reliable
The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are:
(1) There are ...
|
|
Schneider servo model introduction
LXM23DU01M3X servo drive 0.1 kW
LXM23DU02M3X servo drive 0.2 kW
LXM23DU04M3X Servo drive 0.4 kW
LXM23DU07M3X Servo drive 0.75 kW
LXM23DU10M3X ...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
Inverter selection and capacity matching - Schneider
In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate.
...
|
|
Frequency converter main circuit fault solution - Schneider
According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...
|
|
The role of Schneider thermal relays
The effect of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and bent to advance the action mechanism to drive the contact action, so as to disconnect the motor control circuit to complete the motor power-off thermal relay ...
|
|
Schneider molded case and miniature circuit breaker recommended models
Molded case circuit breaker recommendation
Schneider EZD series
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution by Schneider Electric, which is especially suitable for ...
|
|
Schneider inverter and PLC connection problems
When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Schneider online UPS power supply is energy-saving
1. The need for stability
When choosing UPS products, the customer's focus must be stability. For UPS, higher power means lower calorific value. Of course, only one of the primary factors that affect the internal temperature of the UPS is also to consider the heat dissipation planning of the machine itself.
...
|
|
Inverter trip protection circuit – Schneider
After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time.
Inverter hopping ...
|
|
The reason for the inverter trip - Schneider
Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about.
1. Overload jump ...
|