Sunland inverter control panel button function

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. The "FUNC/DATA" key is a programming key, press this button once to convert the operation mode, and press it again to read and write the function code;

2. The "SET/>>" button is the display switch and shift key, press this key to switch the display content, and press it again to shift the data.

3. The "^" and "v" keys are data ascending and lowering keys, and pressing this key can not only change the selection of the function code, but also change the selection of the data code. It can also be used to change the operation of a given frequency in the operating mode.

4. The "RUN" button is used to operate the motor under the keyboard control mode.

5. The "STOP/RESET" key is mainly used to stop the machine in the way of the keyboard, and can be reset when the inverter has a soft fault.

                               Sunland inverter control panel button function

More on that
The inverter is different from the inverter power supply - Senland The inverter is different from the inverter power supply - Senland

In terms of power supply, everyone may know that the inverter and the inverter power supply are auxiliary equipment for charging electrical appliances, but many people do not know what is the inverter power supply and what is the inverter. With the continuous progress of the times, electrical appliances will be constantly updated, and auxiliary equipment is constantly changing.

Inverter parameter setting method - Senlan Inverter parameter setting method - Senlan

1. Control method: i.e. speed control, rotation control, PID control, or other methods. After the control method is adopted, it is generally necessary to carry out static or dynamic identification according to the control accuracy. 2. Minimum operating frequency: That is, the minimum speed of the motor operation, the motor at low speed ...

The cause of leakage of the inverter-controlled motor - Senlan The cause of leakage of the inverter-controlled motor - Senlan

In some fields, the use of inverter to control the motor will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. According to the inverter control motor ...

Application of Sunland inverter on gantry milling machine Application of Sunland inverter on gantry milling machine

The gantry milling machine is a machining equipment for processing larger workpieces, and its electrical control system includes two parts: the main transmission of the workbench and the logical control of the feed organization. Henan Jiaozuo Maike Company has a gantry milling machine, which has been used for many years since the 70s. The main drive of the operating table of the gantry milling machine is selected ...

Precautions for starting electrical equipment after a long holiday - Senlan Precautions for starting electrical equipment after a long holiday - Senlan

1. Do a good job of moisture-proof operations, clean up water and oil stains on site, insist on the boring environment of electrical equipment, and pay attention to preventing the inverter from being exposed. 2. Do a good job of maintenance and maintenance, take advantage of the shutdown for maintenance, clean the frequency conversion dust, and clean the frequency conversion air duct; Tighten the frequency conversion cable joint to prevent loosening, ...

Inverter remote control wiring method - Senlan Inverter remote control wiring method - Senlan

1. Connect X (switching input) drive terminal to control the inverter start-stop/forward and reverse rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control active conditioning frequency) 3. Other DO (switching output) is used for transmission ...

The change of frequency conversion control mode - Senlan The change of frequency conversion control mode - Senlan

In the process of practical speed regulation, a general frequency-adjustable communication power supply can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the problems of using the magnetic field of the motor, pressing the starting current and obtaining the desired torque characteristics, such as low-frequency torque characteristics.

Failure of robot contactor and inverter - Senland Failure of robot contactor and inverter - Senland

Robot contactors are noisy? Cause: It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components. Solution: will control the ...

Sunland inverter does not show fault repair Sunland inverter does not show fault repair

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board operation power supply are independent of each other, the fan power supply output is normal, and the control board operation power supply is not output due to the problem. ...

Common problems in the use of inverter - Sunland inverter Common problems in the use of inverter - Sunland inverter

1. Please explain the maintenance function of the inverter? (1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention. (2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. As...

The difference between vector and general use of frequency converter The difference between vector and general use of frequency converter

1. The control accuracy of the vector type is higher than that of the general type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, and is suitable for use in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If it is used in some of the more common fields ...

Inverter overcurrent protection solution - Senlan Inverter overcurrent protection solution - Senlan

1. Causes of overcurrent There are many reasons for the occurrence of overcurrent, including soft and hard problems. 1. Causes of soft failures When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...

Sunland inverter is used in Baotou steel water supply Sunland inverter is used in Baotou steel water supply

In recent years, with the development of power electronics skills, the frequency conversion speed regulation skills have been very mature, practice has proved that the use of frequency conversion speed regulation in fans, pumps and loads can save 20%-50% of the electric energy, and the use of frequency conversion speed regulation can bring the following advantages in the future, its biggest advantage is that it has ...

Hope Senlan inverter control panel button function diagram Hope Senlan inverter control panel button function diagram

Hope Senlan inverter control panel button function diagram 1. The "FUNC/DATA" button is a programming key, press this button once to convert the operation mode, and press it again to read and write the utility code. 2."S ...

Motor encoder and rotor pole phase zero alignment repair - Sunland Motor encoder and rotor pole phase zero alignment repair - Sunland

1. Phase alignment method of incremental encoder The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows: 1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...

Sunland inverter electromagnetic interference suppression method Sunland inverter electromagnetic interference suppression method

When the peripheral equipment and the inverter share the same power supply, the disturbance generated by the inverter is transmitted against the power line, which will cause other equipment in the same system to malfunction. The following methods can be adopted: (1) The input device of the inverter is equipped with an EMI filter or a ferrite common-mode filter (magnetic ring) ...

Hope Sunland inverter fault code Hope Sunland inverter fault code

Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor There is a short circuit in the motor wiring The starting voltage is too high Check the motor and wiring Check the motor wiring Seek service Check the torque boost settings ...

Senlan inverter chemical industry air compressor application precautions Senlan inverter chemical industry air compressor application precautions

1. Due to the large moment of inertia of the air compressor, the capacity of the inverter should be determined according to the specific working conditions and the operating current of the site. 2. The pressure sensor should be in the pressure change is not relative...

About the basic selection of Hope Sunland inverter About the basic selection of Hope Sunland inverter

It is hoped that Sunland low-voltage inverter can be divided into four series: 1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge ...

Sunland's measures to reduce inverter failure Sunland's measures to reduce inverter failure

According to the test, the service life of the inverter is halved for every 10°C increase in the operating ambient temperature. For this reason, in daily use, a reasonable maintenance cycle and guidelines should be formulated according to the actual operating environment and load characteristics of the inverter.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top