The reason for the increase of the torque of the inverter - Senlan inverter

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

It is important to set the torque to improve the function. When the power frequency of the motor decreases, the speed of the motor will also decrease, and if the load torque remains unchanged, the output power will also decrease. According to the principle of conservation of energy, if the torque of the load is unchanged, the current cannot be reduced, and the energy balance between the input and output can only be maintained by reducing the voltage. Let the corresponding voltage of the motor input be Ux and the frequency drop is fx, then:

(1) Voltage conditioning ratio Ku=Ux/Un

(2) Frequency conditioning ratio Kf=fx/fn

where Un and fn. They are additional voltage and additional frequency. When Ku=Kf, the voltage and frequency drop in direct proportion. Because the speed of the motor is determined by the frequency, the specific reflection of the decrease in the share of output power is the reduction of electromagnetic torque, which reduces the ability of the motor to carry the load, if you do not reduce the ability of the motor to carry the load, when the voltage and frequency drop at the same time, the voltage should be appropriately increased on the basis of Ku=Kf, so that Ku>Kf. Because the purpose of increasing the voltage is to increase the torque, it is called torque increase, also known as torque compensation. The increase in torque reflects the ratio of voltage to frequency, and the increase in debugging torque is actually the adjustment of the U/f ratio.

                         The reason for the increase of the torque of the inverter - Senlan inverter

More on that
Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

Calculation method of braking resistance and power of inverter - Sunland inverter Calculation method of braking resistance and power of inverter - Sunland inverter

(1) Brake usage rate ED% Brake usage rate ED%, that is, the brake usage rate in the clarification book ED%. The brake utilization rate ED% is said to be the deceleration time T1 divided by the deceleration cycle T2, and the brake utilization rate is mainly to allow the braking unit and the brake resistance to have sufficient time to dissipate ...

The difference between strong and weak inverter - Sunland inverter The difference between strong and weak inverter - Sunland inverter

The inverter includes a rectifier circuit and an inverter circuit, and the input communication electricity is converted into DC voltage through the rectifier circuit and flat-wave circuit, and then through the difference between strong and weak current, it is mainly reflected in the different uses. Strong electricity is used as a kind of power power, and weak electricity is used for information transmission. In detail ...

Hope Sunland inverter fault code Hope Sunland inverter fault code

Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor There is a short circuit in the motor wiring The starting voltage is too high Check the motor and wiring Check the motor wiring Seek service Check the torque boost settings ...

Inverter super password summary Inverter super password summary

1. Delta's super password-B series: 57522; - H-series: 33582; S1 series inverter universal password: 575222. Second, Huifeng inverter (that is, now Ou Rui inverter), the general super password of its products is: 18881500-G 1500-P 1000- ...

The eight forbidden areas of inverter control loop wiring - Senlan The eight forbidden areas of inverter control loop wiring - Senlan

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Inverter line control mode - Senlan inverter Inverter line control mode - Senlan inverter

Each inverter (Variable-frequency Drive, VFD) is subject to different line control, and the methods of voltage control and current control can be divided into two categories, one is voltage type and the other is current type. The control mode can also be divided into voltage control and current type. The main circuit method and ...

Motor inverter principle and precautions for use - Senlan Motor inverter principle and precautions for use - Senlan

The difference between a voltage converter and a current converter Voltage inverter and current inverter are two different operating principles, for example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the effect of conditioning, while the current inverter is a direct ...

It is hoped that Senlan will become the most powerful shore power solution provider in China It is hoped that Senlan will become the most powerful shore power solution provider in China

Founded in 1998, Hope Lansen is a national high-tech enterprise in the fields of energy conservation and environmental protection, new energy, transmission control and intelligent equipment in China, integrating R&D, manufacturing, system integration and customer service. Its products cover high and low voltage frequency conversion control systems, automated production lines and robot transmission systems.

Causes and treatment methods of inverter inverter module damage - Senlan Causes and treatment methods of inverter inverter module damage - Senlan

Most of the damage of the inverter module is due to the damage of the driving electric, which causes the two switching devices on one bridge arm to be turned on at the same time. Inverter inverter power module damage is a common problem in other inverter equipment such as vector inverter or energy-saving inverter.

The main circuit of the inverter application - Hope Sunland The main circuit of the inverter application - Hope Sunland

There is a circuit breaker QF and a communication contactor KM between the power supply and the inverter, when the inverter does not need to be used for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. It has maintenance functions such as overcurrent and undervoltage. The main power of the inverter ...

How to expand the application range of inverter - Sunland inverter How to expand the application range of inverter - Sunland inverter

In the electrical profession, the use and development of energy-saving frequency conversion is very good, which has promoted the electrical profession to reach the pinnacle of science and technology again. Frequency converter (VFD) has a very good development shape in China, but it still has to withstand various tests. As long as you give full play to your professional advantages, you can gain a firm foothold in this society. VFD ...

Inverter with no-load operation and commissioning - Senlan Inverter with no-load operation and commissioning - Senlan

(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter. (2) Set the maximum output frequency and base frequency of the inverter and set the torque characteristics of the motor. Pressure/Frequency (V/F) Operators ...

The control performance standard of the inverter cabinet The control performance standard of the inverter cabinet

The control specifications of the inverter cabinet include reliability, accuracy, safety, environmental habits and versatility, etc., which are important guarantees to ensure the normal operation and safe production of the inverter cabinet control system. Reliability specification: The control system should have high reliability and can be used for a long time.

Application of Sunland inverter in sugar separator Application of Sunland inverter in sugar separator

First, the operation of the machine before the technical transformation The sugar separation process of a sugar factory in Yunnan uses centrifugal dehydration method. The separation machine is mainly composed of a cone drum and a drive motor, and the motor shaft is directly connected to the bowl. Solid sugar crystallized from a high concentration of sugar water, in a cone bowl ...

What are the protection functions of the inverter - Sunland inverter What are the protection functions of the inverter - Sunland inverter

1. Incoming line maintenance Incoming maintenance is the maintenance of the user's inlet end and inverter, including lightning protection maintenance, grounding maintenance, phase loss maintenance, inverted phase maintenance, unbalance maintenance, overvoltage maintenance, transformer maintenance and so on. These maintenance devices are generally installed at the input of the inverter ...

Sunland proposed a multi-machine parallel high-voltage shore power supply system solution Sunland proposed a multi-machine parallel high-voltage shore power supply system solution

Air pollution in port cities mainly comes from cargo loading and unloading operations and emissions from ships calling at ports; Shore power connection refers to the closure of the auxiliary engine during the port of the vessel, and the shore power is supplied by the port. At 9:08 on December 25, 2018, the world's first ...

The reason why the inverter damaged the motor - Senlan The reason why the inverter damaged the motor - Senlan

The presentation of inverters has brought a revolution to industrial automation control and motor energy saving. Industrial production is simply inseparable from the inverter, even in the daily livelihood, elevators, inverter air conditioning has become a part of the insistence, inverter from the beginning into all corners of production, subsistence. However...

Senlan frequency conversion cabinet wiring steps Senlan frequency conversion cabinet wiring steps

The wiring of the inverter cabinet refers to the correct connection between the inverter and the motor, power supply and other equipment. The wiring requirements of the cabinet are carried out in accordance with the electrical principles and equipment specifications to ensure the normal operation and safety of the system. The following is the cabinet ...

Hope the advantages of Sunland inverter soft start Hope the advantages of Sunland inverter soft start

It is hoped that Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which can meet the needs of various applications. The advantages of Hope Sunland inverter and soft start are: 1. **Sex: I hope that Sunland inverter and ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top