LS produces common sense of electroplastic case circuit breaker

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

(1) Tripping

LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a thermomagnetic tripping or electronic tripping, and we must also understand this different tripping method in advance.

In the process of practical application, if there are requirements for the capacity of LS electric molded case circuit breakers, you can choose some special molded case circuit breaker types, Let's also understand the price of molded case circuit breakers, because of the molded case circuit breaker if it chooses different tripping methods, its price will be very different, we must understand at the time of acquisition, manufacturers in terms of detailed price rules, in addition to understanding the practical working conditions of molded case circuit breakers, Due to the practical application of the molded case circuit breaker, it will also have certain requirements for the ambient air temperature.

                                 LS produces common sense of electroplastic case circuit breaker

(2) Temperature

If the temperature is too high or too low, it may have a bad impact on the molded case circuit breaker, Now, the working conditions of the molded case circuit breaker generally require that the high temperature cannot exceed 40 degrees, and the low temperature cannot be lower than minus 5 degrees.

We must consult the manufacturer about the upper and lower limits of the temperature of the molded case circuit breaker in the practical application process, some times the price of the product supplied by a manufacturer may be relatively low, we will feel that this thing is very cost-effective, but if you deepen your understanding, you will find that its practical application process on the working conditions of the requirements are more stringent, so this will also affect the later use, we should also be particularly aware of this problem in the process of use

More on that
Fault solution for three-phase asynchronous motor - LS power generation Fault solution for three-phase asynchronous motor - LS power generation

1. The motor cannot roll after being energized, but there is no abnormal noise, no peculiar smell and smoke. 1. Cause of the problem: (1) The power supply is not connected (at least two phases are not connected); (2) Fuse blowing (at least two-phase blowing); (3) The overcurrent relay is adjusted too small; (4) The wiring of the control equipment is faulty. 2. Question ...

Types and characteristics of PLC digital output modules for power production Types and characteristics of PLC digital output modules for power production

  The main functions and functions of PLC: 1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...

Explanation of basic terms of electrician - electricity production Explanation of basic terms of electrician - electricity production

1. Active power - in the process of generating and transmitting alternating current energy, the part of energy used to convert into electromagnetic methods is called active power 2. Reactive power - in the process of AC electric energy generation and transmission, it is used for electromagnetic field AC in the circuit.

Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

How LS produces power PLC operation How LS produces power PLC operation

Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.

LS Electric helps Cisco Smart City build an industry benchmark LS Electric helps Cisco Smart City build an industry benchmark

In March 2019, LS Group signed a strategic cooperation agreement with Country Garden to build Cisco Smart City into an innovative model for smart cities. LS Electric will provide power distribution system solutions for Cisco (Guangzhou) Smart City, providing frame circuit breakers, molded case circuit breakers, vacuum circuit breakers, miniature circuit breakers, and micro circuit breakers.

The working principle of LS PLC module The working principle of LS PLC module

When LS PLC is put into operation, its operation process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the operation, the PLC's CPU repeatedly performs the performance at a certain scanning speed on ...

The lightning protection port of the inverter - LS generates electricity The lightning protection port of the inverter - LS generates electricity

According to the applied engineering practice, variable frequency drive (VFD) lightning strikes can be roughly divided into direct lightning, induced lightning and conducted lightning. But no matter what form it takes to reach the device, it can be summarized as a lightning surge from the following four parts, which are called lightning protection ports here, with V ...

The working principle of the LS power production module The working principle of the LS power production module

When the LS power generation module is put into operation, its working process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...

Specification steps for the safe operation of generator sets – power generation Specification steps for the safe operation of generator sets – power generation

Standardized procedures for safe operation of generator sets 1. Preparation before starting (1) The operators of the computer room should abide by the safety operation procedures, wear work clothes and insulated shoes, and the crew should have a clear division of labor. (2) Check whether the flywheel and part of the generator are not defective. ...

The matrix alternating control mode of the inverter - LS power generation The matrix alternating control mode of the inverter - LS power generation

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. One of the disadvantages is that the input power factor is low, the harmonic current is large, the DC circuit needs a large energy storage capacitor, and the regenerative energy cannot be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

The difference between input reactor and output reactor – LS produces electricity The difference between input reactor and output reactor – LS produces electricity

The rectifier part of the general inverter selects the diode uncontrollable bridge rectifier circuit, and the middle filter part selects the large capacitor as the filter, so the input current of the rectifier is actually the charging current of the capacitor, and the harmonic component is relatively steep and steep.

Inverter switching power supply circuit vein - LS power generation Inverter switching power supply circuit vein - LS power generation

1. Vibration circuit: the drainage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels for the working current of the power supply; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

Safety precautions for LS inverters Safety precautions for LS inverters

1. When the power supply is now powered or the inverter is in operation, do not open the shell of the inverter. Otherwise, an electric shock may occur. 2. When the front cover of the inverter is opened, do not run the inverter. Otherwise, you may be subjected to ...

Several basic functions of the inverter - LS generates electricity Several basic functions of the inverter - LS generates electricity

The inverter mainly has the following functions: 1. Soft up The direct launch of the inverter motor will have a severe impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits.

What are the determinants of the performance of LS inverters? What are the determinants of the performance of LS inverters?

The quality of the control circuit determines the function of the LS inverter. The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a high-quality DC power supply. When the whole ...

Inverter overvoltage fault analysis method - LS power generation Inverter overvoltage fault analysis method - LS power generation

The overvoltage of the inverter is manifested in the tributary voltage of the DC bus. Under normal conditions, the direct current of the inverter is the average value of the three-phase full-wave rectification. If calculated by 380V line voltage, the average DC voltage Ud=1.35U line=513V.

Inverter failure and solution - power generation Inverter failure and solution - power generation

1. HW problem This problem may be a fault unique to LG-IG5 series inverters, and the main causes are as follows: (1) Damage to the cooling fan. Due to the use of environmental and other factors, the friction of the fan bearing is too large, causing the fan load to be too large and showing H ...

Cycloidal reducer transmission system testing - LS power production Cycloidal reducer transmission system testing - LS power production

With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects. ...

Dealing with the "transient" fault method of DP slave - LS power generation Dealing with the "transient" fault method of DP slave - LS power generation

Due to poor contact of network connectors, or due to disturbance and other problems, DP networks that have been used for a long time may show a "transient disconnection" situation, that is, occasionally disconnected instantaneously, and quickly recover to normal. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top