Inverter switching power supply circuit vein - LS power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. Vibration circuit: the drainage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels for the working current of the power supply; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is a prerequisite for the power supply to vibrate.

                            Inverter switching power supply circuit vein - LS power generation

Of course, PC1's 4-pin external timing components R2 and C2 and the PC1 chip itself also form part of the vibration circuit.

2. Voltage stabilization circuit: N3, D3, C4 and other +5V power supplies, R7-R10, PC3, R5, R6 and other components constitute the voltage stabilization control loop.

Of course, the PC1 chip and the 1 and 2 pin peripheral components R3 and C3 are also part of the voltage regulation circuit.

3. Maintenance loop: The PC1 chip itself and the 3-pin peripheral component R4 constitute an overcurrent maintenance loop; The D2, R6 and C4 components connected in parallel on the N1 winding constitute the maintenance circuit of the IGBT; In essence, the voltage feedback signal of the voltage regulation circuit - the voltage regulation signal can also be regarded as a voltage maintenance signal. However, the content of the maintenance circuit is not limited to the maintenance circuit itself, and the start and control of the maintenance circuit is often caused by the abnormality of the load circuit.

4. Load circuit: N3, N4 secondary winding and subsequent circuits, all of which are load circuits. The abnormality of the load circuit will involve the maintenance circuit and the voltage regulation circuit, so that the two circuits can make corresponding maintenance and adjustment actions.

More on that
LS power production contactor selection LS power production contactor selection

How LS Contactor Works: Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...

LS inverter frequency conversion mode LS inverter frequency conversion mode

1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...

How does the interference of the frequency converter occur? -- Electricity production How does the interference of the frequency converter occur? -- Electricity production

To discuss the disturbance problem of LS inverter, we must first understand the operating principle of inverter, from the structural point of view, inverter is divided into direct inverter and direct inverter. The direct inverter is a communication that directly converts the I frequency current into a controllable frequency, and there is no intermediate DC link. Each phase of it ...

Wiring method of the main circuit of the inverter - LS power generation Wiring method of the main circuit of the inverter - LS power generation

1. The power supply should be connected to the R, S, and T terminals of the VFD, and should not be connected to the VFD (U, V, W), otherwise the VFD will be damaged. It is necessary to clean up the trivial parts of the wire head after wiring, which may lead to abnormalities, failures, and failures, and it is necessary for the VFD to always be clean. When punching holes in the console, note that ...

Distinguish between good and bad inverters - LS produces electricity Distinguish between good and bad inverters - LS produces electricity

The quality of a thing is relatively speaking, the inverter as a power supply used to drive the motor to run, its function is to regulate the speed, under the premise of normal wiring, reasonable parameters, and no fault with the load, if the speed of the motor can be controlled according to the requirements, the shaking error is less than the equipment ...

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

LG Inverter-LS Inverter-IGXA Sales LG Inverter-LS Inverter-IGXA Sales

LG Inverter LS Inverter IGXA Series ** for sale, its models are as follows: SV004IGXA-4 60210101W0 Power 0.37KW (Input: 3-phase 380V / Output: 3-phase 0——380V)   SV008IGXA-4 6021010 ...

Switching analysis and synchronous control of inverter - LS power generation Switching analysis and synchronous control of inverter - LS power generation

AC asynchronous motors are widely used in all walks of life, and frequency converters and power frequency power supplies are often required to switch in the selection of frequency conversion speed control system. The primary types of switching are: fault switching and multi-machine system switching. In the process of operation of many production machinery, the motor is not allowed to stop ...

Analysis of the fault problem of LS power terminal block Analysis of the fault problem of LS power terminal block

From the point of view of application, the function of the terminal block should be achieved: it is necessary to conduct the local conduction of the touch part, and the touch is reliable. The insulating part should not be conducted, and it is necessary to insulate it firmly. There are three common forms of fatal problems in terminal blocks: ...

What is the difference between LS inverter and LG inverter? What is the difference between LS inverter and LG inverter?

LS inverter and LG inverter are the same, there is no difference between the two. LS inverter, the full name of LS AC inverter governor, after supplying a variety of configurations, converts direct current into communication power, and changes the general power supply ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

Interference phenomenon that often occurs in LS power inverters Interference phenomenon that often occurs in LS power inverters

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

How to choose LS contactors How to choose LS contactors

The working form of LS contactor: Generally speaking, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and make their AC contactor ...

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Contactors play a role in industrial electricity Contactors play a role in industrial electricity

The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power

What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized? In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...

Precautions for the maintenance of the inverter of the tensile testing machine - LS generates electricity Precautions for the maintenance of the inverter of the tensile testing machine - LS generates electricity

In the course of regularly checking the variable-frequency drive (VFD) of the tensile testing machine, we can visually check the operating status directly from the outside. (1) The ambient temperature is normal, and it is required to be between -10°C and +40 ...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

How to use the installation wiring of the LS inverter How to use the installation wiring of the LS inverter

1. Circuit wiring (1) The input (R, S, T) and output (U, V, W) of the inverter cannot be connected incorrectly; (2) Wire diameter selection (1) The wiring of the power supply and the inverter and the wire diameter selection method of the motor of the same capacity are the same; (2) The wiring between the inverter and the motor should consider the line electricity.

Introduction to vector control of inverter and motor - LS power generation Introduction to vector control of inverter and motor - LS power generation

As for the use of vector-operated motors, it can be divided into two categories, namely non-reactive vector control (SVC) and reactive vector control (FVC). Vectorless Handling (SVC): Due to the speed response, additional equipment for the encoder is installed in the motor dragged by the inverter, which is cumbersome. Here...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top