Features of the output reactor:
1. It is suitable for reactive power compensation and harmonic management
2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively maintain the Mitsubishi inverter and improve the power factor, which can block the disturbance from the power grid and reduce the pollution of the harmonic current generated by the rectifier unit to the power grid.
The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and can reduce the noise of the Mitsubishi inverter by pressing the harmonics output of the Mitsubishi inverter. Some manufacturers also provide the maximum allowable length of wires connected to the motor with and without output reactors.
Features of the input reactor:
1. It is suitable for reactive power compensation and harmonic management
2. The input reactor is used to restrain the current impulse caused by the sudden change of grid voltage and the operation of overvoltage; The harmonic effect is filtered to control the distortion of the grid voltage waveform; 3. The spike pulse contained in the slippery power supply voltage, and the voltage defect that occurs during the commutation of the slippery bridge rectifier circuit; In the Mitsubishi inverter system with DC link, the DC reactor can effectively improve the power factor after the rectifier, and the power factor can be increased to 0.95 with proper coordination, in addition, the DC reactor can make the inverter run stably, and can constrain the short-circuit current, so many manufacturers produce more than 55kW Mitsubishi inverter is supplied with DC reactor randomly.
|
More on that
|
Mitsubishi inverter FR-E024-0.75K repair
Type: FR-E024-0.75K
Fault: The boot cannot be started
Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...
|
|
Software or hardware reasons for Mitsubishi PLC crash
1. Hardware
(1) I/O channeling, the PLC automatically detects the I/O fault and enters the STOP mode.
(2) The I/O is damaged, and the program runs to the response signal that needs the I/O, and cannot execute the instruction downward.
(3) Expansion module (functional, such as A/D) ...
|
|
PLC troubleshooting method - Mitsubishi
1. If the PLC stops in the middle of some outputs where the output is excited, then look for the signal that caused the next operation (input, timer, line, drum manipulator, etc.). The programmer will show the ON/OFF status of that signal.
...
|
|
Mitsubishi FR-A700 series inverter problem
1. Consultation question: FR-A700 series Mitsubishi inverter, the suffix is ending in -CA1, what kind of inverter?
Solution: The suffix -CA1 is a special model with take-up control.
2. Consultation question: FR-A ...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. Whereas...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation imitation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. Assuming that the load on the motor shaft is less than 2.5Nm, then ...
|
|
Analysis of PLC and inverter connection problems - Mitsubishi
When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1. PLC switch command signal input
Inverter input ...
|
|
The wiring steps of the input and output circuits of the Mitsubishi PLC
The wiring diagram steps of the input and output circuit of Mitsubishi PLC, there are generally three types in the wiring diagram of the input and output of the PLC, one is DC 12-24V input, and there is output, so what about the external input?
(1 ...
|
|
The reason why the computer programming software and the Mitsubishi PLC cannot communicate
What is the reason why the programming software on the computer and the Mitsubishi PLC cannot communicate? How do I set the port of the communication line?
There are several reasons why communication may not be available:
1. It may be that the PLC is not energized;
2. Programming software to create ...
|
|
Introduction to the capacitive role of Mitsubishi inverter
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles.
...
|
|
PLC controller and human-machine interface anti-interference countermeasures - Mitsubishi
When carrying out anti-disturbance planning for specific projects, it is necessary to select products with high anti-disturbance ability, and adopt methods such as pressing the disturbance source, cutting off or attenuating the propagation path of electromagnetic disturbance, and using software means to improve the anti-disturbance ability of equipment and systems.
...
|
|
The difference between the measurement of ordinary motors and inverter motors - Mitsubishi
1. The actual output waveform of the inverter is PWM wave, which contains carrier signals in addition to the fundamental wave. The carrier signal frequency is much higher than that of the fundamental wave, and it is a square wave signal, which contains a lot of higher harmonics, and the test system requires a higher sampling frequency and bandwidth.
...
|
|
Mitsubishi inverter encountered problems and solutions
1. If you want to use the inverter to drive the motor with a capacitor to improve the power factor, but the motor does not move, please explain the reason.
The current flowing into the inverter is used to improve the power factor, but the capacitor cannot be started because its charging current causes the inverter overcurrent (OCT), as a countermeasure, ...
|
|
Features of Mitsubishi PLC programming language
1. Graphical instruction structure: The program is expressed graphically, and the instructions are composed of different graphic symbols, which are easy to understand and remember. In the logic operation part, almost all manufacturers use a ladder diagram similar to the relay control circuit, which is easy to accept. More complex arithmetic operations, ...
|
|
Inverter life extension method - Mitsubishi
First, the frequency converter should not be installed on the equipment with a sensation, because the main circuit connection screw in the frequency converter is simply loose, and many frequency converters are damaged due to this reason.
Second, the wiring problem: the input end of the inverter is connected to an air The initial maintenance current should not be too large, ...
|
|
Fault analysis of Mitsubishi inverter OC1 and OC3
Mitsubishi inverter OC (overcurrent problem) will be caused by the following reasons, taking A500 series inverter as an example:
1). Caused by improper parameter setting problems, such as time setting is too short.
2). ...
|
|
Review and comparison of Mitsubishi PLC control inverter methods
1. The switching signal of PLC controls the inverter
The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...
|
|
Characteristics of servos and advantages of Mitsubishi servos
The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.
|
|
Pay attention to the wiring of the Mitsubishi PLCI/O terminal
1. Enter the wiring
(1) The input wiring should generally not exceed 30 meters. However, if the environmental disturbance is small and the voltage drop is not large, the input wiring can be appropriately longer.
(2) The input/output lines cannot be separated by the same cable, and the input/output lines should be separated.
(3) As far as possible, choose normally open ...
|
|
Mitsubishi inverter control method
There are several ways to classify Mitsubishi inverters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
Depend on...
|
|